High-pitch dual-source CT coronary angiography: analysis of the impact on image quality of altered electrocardiography waves during data acquisition.

Xiaoling Wang1, Jiliang Fang, Haibin Tong, Qing Zhao, Qingqiao Song, Ping Luo, Chao Xue, Min Zhang, Shuhua Yang, Qun Wang, Ping Wang, Fengxiang Shi, Lei Xu, Peijing Rong.   

Abstract

Electrocardiography (ECG) "altered waves" sometimes occur during data acquisition when computed tomography coronary angiography (CTCA) is performed with the prospectively ECG-triggered high-pitch (Flash spiral) mode using a second-generation dual-source CT. The aim of this study was to assess the effect of the ECG altered waves on image quality. Seventy-three consecutive patients with stable sinus rhythm ≤ 65 beats per minute were retrospectively enrolled in this study. CTCA was performed using the Flash spiral mode in which the data acquisition was prospectively triggered at 60 % of the R-R interval and completed within one cardiac cycle. The ECG waves before and during data acquisition were analyzed for grouping purposes. Image quality was evaluated using a four-point scale (1 = best, 4 = unevaluatable). Thirty patients (group 1) were found to have ECG altered waves during data acquisition, while 43 patients (group 2) had ECG "stable waves." The altered waves were seen as the baseline drifting; the broad, erected, or inverted P wave or QRS complexes; and a new wave. However, the length of the R-R interval did not change during the data acquisition. There were no significant differences in image quality scores between the two groups on the per-patient (2 ± 0.87 vs. 2.2 ± 0.74, P = 0.273) or per-segment (1.27 ± 0.54 vs. 1.32 ± 0.55, P = 0.577) basis. There were no significant differences in coronary evaluatability as well (per-patient; 93.3 vs. 95.3 %, P = 0.352; per-segment; 99.4 vs. 99.6 %, P = 1.0). CTCA image quality is not affected by ECG altered waves during data acquisition using the Flash spiral mode in low and stable heart rate patients. Thus, the ECG altered waves are considered artifacts.

Entities:  

Mesh:

Year:  2012        PMID: 22692450     DOI: 10.1007/s10554-012-0078-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  15 in total

1.  Diagnostic image quality of a comprehensive high-pitch dual-spiral cardiothoracic CT protocol in patients with undifferentiated acute chest pain.

Authors:  Fabian Bamberg; Roy Marcus; Wieland Sommer; Florian Schwarz; Konstantin Nikolaou; Christoph R Becker; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 3.  Electrode misconnection, misplacement, and artifact.

Authors:  Richard A Harrigan
Journal:  Emerg Med Clin North Am       Date:  2006-02       Impact factor: 2.264

4.  ECG artifacts during intraoperative high-field MRI scanning.

Authors:  Torsten Birkholz; Markus Schmid; Christopher Nimsky; Jürgen Schüttler; Bernd Schmitz
Journal:  J Neurosurg Anesthesiol       Date:  2004-10       Impact factor: 3.956

5.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

6.  High-pitch electrocardiogram-triggered computed tomography of the chest: initial results.

Authors:  Michael Lell; Fabian Hinkmann; Katharina Anders; Paul Deak; Willi A Kalender; Michael Uder; Stephan Achenbach
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

7.  Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition.

Authors:  Stephan Achenbach; Mohamed Marwan; Dieter Ropers; Tiziano Schepis; Tobias Pflederer; Katharina Anders; Axel Kuettner; Werner G Daniel; Michael Uder; Michael M Lell
Journal:  Eur Heart J       Date:  2009-11-05       Impact factor: 29.983

8.  Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique.

Authors:  Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Anno Graser; Gisela Michalski; Klement Neumaier; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-02       Impact factor: 6.016

9.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

Review 10.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

View more
  2 in total

Review 1.  Cardiovascular imaging 2012 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2013-04       Impact factor: 2.357

2.  Comparison Between Prospectively Electrocardiogram-Gated High-Pitch Mode and Retrospectively Electrocardiogram-Gated Mode for Dual-Source CT Coronary Angiography.

Authors:  Mustafa Koplay; Mahmut Celik; Ahmet Avcı; Hasan Erdogan; Kenan Demir; Mesut Sivri; Alaaddin Nayman
Journal:  Pol J Radiol       Date:  2015-12-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.