Literature DB >> 15557829

ECG artifacts during intraoperative high-field MRI scanning.

Torsten Birkholz1, Markus Schmid, Christopher Nimsky, Jürgen Schüttler, Bernd Schmitz.   

Abstract

High-field magnetic resonance imaging (MRI) (1.5 T) has recently been introduced into the neurosurgical operating room for intraoperative resection control and functional neuronavigational guidance. However, long-lasting neurosurgical procedures in an operating room equipped with a high-field MRI scanner raise new challenges to the anesthesiologist. In particular, monitoring of vital signs during anesthesia requires equipment compatible with working in close vicinity to the strong magnetic field. However, even MRI-compatible electrocardiographic (ECG) monitoring interferes with electromagnetic fields, so several ECG artifacts can be observed in static and pulsed magnetic fields. As shown in this study, pulsed high-frequency fields induce characteristic field frequency-based artifacts in the ECG that can imitate malignant arrhythmia or provoke ST-segment abnormalities. The knowledge of possible and characteristic ECG artifacts during high-field MRI is therefore essential to prevent misinterpretation. Moreover, interference-free parameters such as pulse oximetry or invasive blood pressure curves are highly relevant during intraoperative MRI scans.

Entities:  

Mesh:

Year:  2004        PMID: 15557829     DOI: 10.1097/00008506-200410000-00002

Source DB:  PubMed          Journal:  J Neurosurg Anesthesiol        ISSN: 0898-4921            Impact factor:   3.956


  13 in total

1.  3DQRS: a method to obtain reliable QRS complex detection within high field MRI using 12-lead electrocardiogram traces.

Authors:  T Stan Gregory; Ehud J Schmidt; Shelley Hualei Zhang; Zion Tsz Ho Tse
Journal:  Magn Reson Med       Date:  2014-01-22       Impact factor: 4.668

2.  Anesthetic challenges and outcomes for procedures in the intraoperative magnetic resonance imaging suite: A systematic review.

Authors:  Hedwig Schroeck; Tasha L Welch; Michelle S Rovner; Heather A Johnson; Florian R Schroeck
Journal:  J Clin Anesth       Date:  2018-11-08       Impact factor: 9.452

3.  Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

Authors:  T Stan Gregory; John Oshinski; Ehud J Schmidt; Raymond Y Kwong; William G Stevenson; Zion Tsz Ho Tse
Journal:  Circ Cardiovasc Imaging       Date:  2015-12       Impact factor: 7.792

4.  Adaptive noise cancellation to suppress electrocardiography artifacts during real-time interventional MRI.

Authors:  Vincent Wu; Israel M Barbash; Kanishka Ratnayaka; Christina E Saikus; Merdim Sonmez; Ozgur Kocaturk; Robert J Lederman; Anthony Z Faranesh
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

5.  High-pitch dual-source CT coronary angiography: analysis of the impact on image quality of altered electrocardiography waves during data acquisition.

Authors:  Xiaoling Wang; Jiliang Fang; Haibin Tong; Qing Zhao; Qingqiao Song; Ping Luo; Chao Xue; Min Zhang; Shuhua Yang; Qun Wang; Ping Wang; Fengxiang Shi; Lei Xu; Peijing Rong
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-13       Impact factor: 2.357

Review 6.  [Pitfalls in magnetic resonance imaging. What should the anaesthesiologist know?].

Authors:  S v Paczynski; K P Braun; W Müller-Forell; C Werner
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

7.  Left-ventricular mechanical activation and aortic-arch orientation recovered from magneto-hydrodynamic voltages observed in 12-lead ECGs obtained inside MRIs: a feasibility study.

Authors:  T Stan Gregory; Ehud J Schmidt; Shelley Hualei Zhang; Raymond Y Kwong; William G Stevenson; Jonathan R Murrow; Zion Tsz Ho Tse
Journal:  Ann Biomed Eng       Date:  2014-09-16       Impact factor: 3.934

Review 8.  Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs.

Authors:  Jerold S Shinbane; Patrick M Colletti; Frank G Shellock
Journal:  J Cardiovasc Magn Reson       Date:  2011-10-27       Impact factor: 5.364

Review 9.  MRI-conditional pacemakers: current perspectives.

Authors:  António M Ferreira; Francisco Costa; António Tralhão; Hugo Marques; Nuno Cardim; Pedro Adragão
Journal:  Med Devices (Auckl)       Date:  2014-05-07

Review 10.  Intraoperative magnetic resonance imaging for neurosurgery - An anaesthesiologist's challenge.

Authors:  Rajashree U Gandhe; Chinmaya P Bhave
Journal:  Indian J Anaesth       Date:  2018-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.