Literature DB >> 23584562

Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study.

Abbas Arjmand Shabestari1, Ramin Pourghorban, Mahmood Tehrai, Hamidreza Pouraliakbar, Taraneh Faghihi Langroudi, Hooman Bakhshandeh, Seifollah Abdi.   

Abstract

With advent of transcatheter aortic valve implantation, using multislice computed tomography (MSCT) to provide detailed data about aortic root has become more crucial. We compared aortic dimension changes during cardiac cycle in patients with and without aortic valve calcification and evaluated its correlation with aortic valve calcium score in former group. Fifty-two patients with and 52 subjects without aortic valve calcification underwent coronary MSCT using two 64-slice and a dual-source 256-slice CT scanners. Aortic root dimensions were measured in both systolic and diastolic phases. Changes in annular maximum diameter (D(max)), minimum diameter (D(min)), cross sectional area and perimeter, three diameters of sinuses of Valsalva (V(a), V(b) and V(c)), sinotubular junction maximum (STJ(max)) and minimum (STJ(min)) diameters between systolic and diastolic phases (systole minus diastole) were -0.59 mm, -0.05 mm, -2.53 mm(2), -1.48 mm, +0.91 mm, +1.08 mm, +0.42 mm, +0.63 mm, +0.40 mm and in those without aortic calcification -0.33 mm, 0.00 mm, -6.92 mm(2), -0.41 mm, +0.30 mm, +0.38 mm, +0.61 mm, +0.33 mm, +0.20 mm in patients with aortic calcification, respectively. Apart from two diameters in sinuses of Valsalva (V(a) and V(b)), changes in all other diameters of aortic root during cardiac cycle were not significantly different between the two groups. Furthermore, in patients with aortic calcification, no significant correlation was detected between changes in nearly all aortic root dimensions during cardiac cycle and aortic valve calcium score or location of calcification (annular, commissural or both).

Entities:  

Mesh:

Year:  2013        PMID: 23584562     DOI: 10.1007/s10554-013-0217-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  29 in total

1.  Acute effects of vasoactive drug treatment on brachial artery reactivity.

Authors:  Noyan Gokce; Monika Holbrook; Liza M Hunter; Joseph Palmisano; Elena Vigalok; John F Keaney; Joseph A Vita
Journal:  J Am Coll Cardiol       Date:  2002-08-21       Impact factor: 24.094

2.  Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.

Authors:  Arnold C T Ng; Victoria Delgado; Frank van der Kley; Miriam Shanks; Nico R L van de Veire; Matteo Bertini; Gaetano Nucifora; Rutger J van Bommel; Laurens F Tops; Arend de Weger; Giuseppe Tavilla; Albert de Roos; Lucia J Kroft; Dominic Y Leung; Joanne Schuijf; Martin J Schalij; Jeroen J Bax
Journal:  Circ Cardiovasc Imaging       Date:  2009-11-17       Impact factor: 7.792

3.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?

Authors:  Carl J Schultz; Adriaan Moelker; Nicolo Piazza; Apostolos Tzikas; Amber Otten; Rutger J Nuis; Lisan A Neefjes; Robert J van Geuns; Pim de Feyter; Gabriel Krestin; Patrick W Serruys; Peter P T de Jaegere
Journal:  Eur Heart J       Date:  2009-12-07       Impact factor: 29.983

4.  Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation.

Authors:  Johannes Rixe; Annika Schuhbaeck; Christoph Liebetrau; Helge Moellmann; Holger M Nef; Sebastian Szardien; Roland Brandt; Joern Schmitt; Thomas Neumann; Christian Schneider; Gabriele Krombach; Christian W Hamm; Stephan Achenbach; Andreas Rolf
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

5.  Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance: an integrated index of vascular function?

Authors:  Kennedy Cruickshank; Lisa Riste; Simon G Anderson; John S Wright; Graham Dunn; Ray G Gosling
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

6.  Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation.

Authors:  Philipp Blanke; Wulf Euringer; Tobias Baumann; Jochen Reinöhl; Christian Schlensak; Mathias Langer; Gregor Pache
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

7.  Role of multislice computed tomography in transcatheter aortic valve replacement.

Authors:  David A Wood; Laurens F Tops; John R Mayo; Sanjeevan Pasupati; Martin J Schalij; Karin Humphries; May Lee; Abdullah Al Ali; Brad Munt; Rob Moss; Christopher R Thompson; Jeroen J Bax; John G Webb
Journal:  Am J Cardiol       Date:  2009-05-01       Impact factor: 2.778

8.  Impaired aortic distensibility measured by computed tomography is associated with the severity of coronary artery disease.

Authors:  Naser Ahmadi; Vahid Nabavi; Fereshteh Hajsadeghi; Ferdinand Flores; Shahdad Azmoon; Hussain Ismaeel; David Shavelle; Song S Mao; Ramin Ebrahimi; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2010-08-15       Impact factor: 2.357

9.  Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis.

Authors:  Katarzyna Mizia-Stec; Piotr Pysz; Marek Jasiński; Tomasz Adamczyk; Agnieszka Drzewiecka-Gerber; Artur Chmiel; Michał Krejca; Andrzej Bochenek; Stanisław Woś; Maciej Sosnowski; Zbigniew Gąsior; Maria Trusz-Gluza; Michał Tendera
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

Review 10.  Role of computed tomography imaging for transcatheter valvular repair/insertion.

Authors:  See Hooi Ewe; Robert J Klautz; Martin J Schalij; Victoria Delgado
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

View more
  4 in total

Review 1.  Coronary artery calcium score: a review.

Authors:  Abbas Arjmand Shabestari
Journal:  Iran Red Crescent Med J       Date:  2013-12-05       Impact factor: 0.611

2.  The value of coronary artery calcium score assessed by dual-source computed tomography coronary angiography for predicting presence and severity of coronary artery disease.

Authors:  Alireza Almasi; Hamidreza Pouraliakbar; Ahmad Sedghian; Mohammad Ali Karimi; Ata Firouzi; Mahmood Tehrai
Journal:  Pol J Radiol       Date:  2014-06-30

3.  Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation.

Authors:  Mustafa Elattar; Esther Wiegerinck; Floortje van Kesteren; Lucile Dubois; Nils Planken; Ed Vanbavel; Jan Baan; Henk Marquering
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-23       Impact factor: 2.357

4.  Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients.

Authors:  Mustafa A Elattar; Leon W Vink; Martijn S van Mourik; Jan Baan; Ed T vanBavel; R Nils Planken; Henk A Marquering
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.