Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs.

Xiaoli Li1, William C J Hunter, Tom K Lewellen, Robert S Miyaoka.   

Abstract

We have previously reported on continuous miniature crystal element (cMiCE) PET detectors that provide depth of interaction (DOI) positioning capability. A key component of the design is the use of a statistics-based positioning (SBP) method for 3D event positioning. The Cramer-Rao lower bound (CRLB) expresses limits on the estimate variances for a set of deterministic parameters. We examine the CRLB as a useful metric to evaluate the performance of our SBP algorithm and to quickly compare the best possible resolution when investigating new detector designs.In this work, the CRLB is first reported based upon experimental results from a cMiCE detector using a 50×50×15-mm(3) LYSO crystal readout by a 64-channel PMT (Hamamatsu H8500) on the exit surface of the crystal. The X/Y resolution is relatively close to the CRLB, while the DOI resolution is more than double the CRLB even after correcting for beam diameter and finite X (i.e., reference DOI position) resolution of the detector. The positioning performance of the cMiCE detector with the same design was also evaluated through simulation. Similar with the experimental results, the difference between the CRLB and measured spatial resolution is bigger in DOI direction than in X/Y direction.Another simulation study was conducted to investigate what causes the difference between the measured spatial resolution and the CRLB. The cMiCE detector with novel sensor-on-entrance-surface (SES) design was modeled as a 49.2×49.2×15-mm(3) LYSO crystal readout by a 12×12 array of 3.8×3.8-mm(2) silicon photomultiplier (SiPM) elements with 4.1-mm center-to-center spacing on the entrance surface of the crystal. The results show that there are two main causes to account for the differences between the spatial resolution and the CRLB. First, Compton scatter in the crystal degrades the spatial resolution. The DOI resolution is degraded more than the X/Y resolution since small angle scatter is preferred. Second, our maximum likelihood (ML) clustering algorithm also has limitations when developing 3D look up tables during detector calibration.

Entities:  

Year:  2012        PMID: 22685349      PMCID: PMC3368804          DOI: 10.1109/TNS.2011.2165968

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  9 in total

1.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

2.  Model-based estimation for dynamic cardiac studies using ECT.

Authors:  P C Chiao; W L Rogers; N H Clinthorne; J A Fessler; A O Hero
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

3.  Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.

Authors:  Marnix C Maas; Dennis R Schaart; D J Jan van der Laan; Peter Bruyndonckx; Cedric Lemaître; Freek J Beekman; Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

4.  A high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

5.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

6.  New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

7.  Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

8.  Calibration Method for ML Estimation of 3D Interaction Position in a Thick Gamma-Ray Detector.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

9.  Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Richard Freifelder; Christopher A Cardi; Lars-Eric Adam; Kilian Bilger; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2003-08       Impact factor: 10.057

  9 in total
  3 in total

1.  Evaluation of event position reconstruction in monolithic crystals that are optically coupled.

Authors:  M Morrocchi; W C J Hunter; A Del Guerra; T K Lewellen; P E Kinahan; L R MacDonald; M G Bisogni; R S Miyaoka
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

2.  Impact of the Fano Factor on Position and Energy Estimation in Scintillation Detectors.

Authors:  Vaibhav Bora; Harrison H Barrett; Abhinav K Jha; Eric Clarkson
Journal:  IEEE Trans Nucl Sci       Date:  2015-01-29       Impact factor: 1.679

3.  Depth of interaction determination in monolithic scintillator with double side SiPM readout.

Authors:  Matteo Morrocchi; Giovanni Ambrosi; Maria Giuseppina Bisogni; Filippo Bosi; Marco Boretto; Piergiorgio Cerello; Maria Ionica; Ben Liu; Francesco Pennazio; Maria Antonietta Piliero; Giovanni Pirrone; Vasile Postolache; Richard Wheadon; Alberto Del Guerra
Journal:  EJNMMI Phys       Date:  2017-02-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.