Literature DB >> 18218498

Model-based estimation for dynamic cardiac studies using ECT.

P C Chiao1, W L Rogers, N H Clinthorne, J A Fessler, A O Hero.   

Abstract

The authors develop a strategy for joint estimation of physiological parameters and myocardial boundaries using ECT (emission computed tomography). They construct an observation model to relate parameters of interest to the projection data and to account for limited ECT system resolution and measurement noise. The authors then use a maximum likelihood (ML) estimator to jointly estimate all the parameters directly from the projection data without reconstruction of intermediate images. They also simulate myocardial perfusion studies based on a simplified heart model to evaluate the performance of the model-based joint ML estimator and compare this performance to the Cramer-Rao lower bound. Finally, the authors discuss model assumptions and potential uses of the joint estimation strategy.

Entities:  

Year:  1994        PMID: 18218498     DOI: 10.1109/42.293914

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

Authors:  D J Kadrmas; G T Gullberg
Journal:  Phys Med Biol       Date:  2001-05       Impact factor: 3.609

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  Selection of weighting factors for quantification of PET radioligand binding using simplified reference tissue models with noisy input functions.

Authors:  M D Normandin; R A Koeppe; E D Morris
Journal:  Phys Med Biol       Date:  2012-01-12       Impact factor: 3.609

4.  Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs.

Authors:  Xiaoli Li; William C J Hunter; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2012       Impact factor: 1.679

5.  Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.

Authors:  Arman Rahmim; Yun Zhou; Jing Tang; Lijun Lu; Vesna Sossi; Dean F Wong
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

6.  Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT.

Authors:  Luyao Shi; Yihuan Lu; Jing Wu; Jean-Dominique Gallezot; Nabil Boutagy; Stephanie Thorn; Albert J Sinusas; Richard E Carson; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2019-06-10       Impact factor: 10.048

Review 7.  Direct estimation of kinetic parametric images for dynamic PET.

Authors:  Guobao Wang; Jinyi Qi
Journal:  Theranostics       Date:  2013-11-20       Impact factor: 11.556

8.  Level set method for positron emission tomography.

Authors:  Tony F Chan; Hongwei Li; Marius Lysaker; Xue-Cheng Tai
Journal:  Int J Biomed Imaging       Date:  2007
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.