Literature DB >> 22595980

Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

Pankaj Mishra1, Sara St James, W Paul Segars, Ross I Berbeco, John H Lewis.   

Abstract

Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can include arbitrary lung tumor trajectories. In this work, we present an algorithm that modifies the current XCAT phantom to generate 4D imaging data based on irregular breathing. First, a parameter is added to the existing XCAT phantom to include any arbitrary tumor motion. This modification introduces the desired tumor motion but, comes at the cost of decoupled diaphragm, chest wall and lung motion. To remedy this problem diaphragm and chest wall motion is first modified based on initial tumor location and then input to the XCAT phantom. This generates a phantom with synchronized respiratory motion. Mapping of tumor motion trajectories to diaphragm and chest wall motion is done by adaptively calculating a scale factor based on tumor to lung contour distance. The distance is calculated by projecting the initial tumor location to lung edge contours characterized by quadratic polynomials. Data from ten patients were used to evaluate the accuracy between actual independent tumor location and the location obtained from the modified XCAT phantom. The RMSE and standard deviations for ten patients in x, y, and z directions are: (0.29 ± 0.04, 0.54 ± 0.17, and0.39 ± 0.06) mm. To demonstrate the utility of the phantom, we use the new phantom to simulate a 4DCT acquisition as well as a recently published method for phase sorting. The modified XCAT phantom can be used to generate more realistic imaging data for enhanced testing of algorithms for CT reconstruction, tumor tracking, and dose reconstruction.

Entities:  

Mesh:

Year:  2012        PMID: 22595980      PMCID: PMC3645299          DOI: 10.1088/0031-9155/57/11/3597

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging.

Authors:  P H Pretorius; M A King; B M Tsui; K J LaCroix; W Xia
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Artifacts in computed tomography scanning of moving objects.

Authors:  George T Y Chen; Jong H Kung; Kevin P Beaudette
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

3.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal.

Authors:  S S Vedam; P J Keall; V R Kini; H Mostafavi; H P Shukla; R Mohan
Journal:  Phys Med Biol       Date:  2003-01-07       Impact factor: 3.609

4.  MAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetry.

Authors:  R Kramer; H J Khoury; J W Vieira; V J M Lima
Journal:  Phys Med Biol       Date:  2006-06-26       Impact factor: 3.609

5.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

6.  Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers.

Authors:  Ross I Berbeco; Hassan Mostafavi; Gregory C Sharp; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

7.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

8.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  10 in total

1.  A mass-conserving 4D XCAT phantom for dose calculation and accumulation.

Authors:  Christopher L Williams; Pankaj Mishra; Joao Seco; Sara St James; Raymond H Mak; Ross I Berbeco; John H Lewis
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

2.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

3.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

4.  An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images.

Authors:  Pankaj Mishra; Ruijiang Li; Raymond H Mak; Joerg Rottmann; Jonathan H Bryant; Christopher L Williams; Ross I Berbeco; John H Lewis
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

5.  Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging.

Authors:  Arda Könik; Caitlin M Connolly; Karen L Johnson; Paul Dasari; Paul W Segars; P H Pretorius; Clifford Lindsay; Joyoni Dey; Michael A King
Journal:  Phys Med Biol       Date:  2014-06-13       Impact factor: 3.609

6.  3D delivered dose assessment using a 4DCT-based motion model.

Authors:  Weixing Cai; Martina H Hurwitz; Christopher L Williams; Salam Dhou; Ross I Berbeco; Joao Seco; Pankaj Mishra; John H Lewis
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

7.  Evaluation of 3D fluoroscopic image generation from a single planar treatment image on patient data with a modified XCAT phantom.

Authors:  Pankaj Mishra; Ruijiang Li; Sara St James; Raymond H Mak; Christopher L Williams; Yong Yue; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2013-01-21       Impact factor: 3.609

8.  Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver.

Authors:  Matthew D Belley; William Paul Segars; Anuj J Kapadia
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

9.  A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections.

Authors:  Jie Wei; Ming Chao
Journal:  Phys Med       Date:  2018-01-11       Impact factor: 2.685

10.  Normal lung tissue complication probability in MR-Linac and conventional radiotherapy.

Authors:  Somayeh Gholami; Francesco Longo; Sara Shahzadeh; Hassan Ali Nedaie; Ryan Sharp; Ali S Meigooni
Journal:  Rep Pract Oncol Radiother       Date:  2020-09-29
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.