Literature DB >> 16177484

Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers.

Ross I Berbeco1, Hassan Mostafavi, Gregory C Sharp, Steve B Jiang.   

Abstract

Due to the risk of pneumothorax, many clinicians are reluctant to implant radiopaque markers within patients' lungs for the purpose of radiographic or fluoroscopic tumour localization. We propose a method of gated therapy using fluoroscopic information without the implantation of radiopaque markers. The method presented here does not rely on any external motion signal either. Breathing phase information is found by analysing the fluoroscopic intensity fluctuations in the lung. As the lungs fill/empty, the radiological pathlength through them shortens/lengthens, giving brighter/darker fluoroscopic intensities. The phase information is combined with motion-enhanced template matching to turn the beam on when the tumour is in the desired location. A study based on patient data is presented to demonstrate the feasibility of this procedure. The resulting beam-on pattern is similar to that produced by an external gating system. The only discrepancies occur briefly and at the gate edges.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16177484     DOI: 10.1088/0031-9155/50/19/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  34 in total

1.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

Authors:  Pankaj Mishra; Sara St James; W Paul Segars; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

3.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

4.  Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Authors:  Zachary Grelewicz; Andrew H Belcher; Rodney D Wiersma
Journal:  Med Phys       Date:  2018-10-09       Impact factor: 4.071

5.  Effect of secondary particles on image quality of dynamic flat panels in carbon ion scanning beam treatment.

Authors:  S Mori; S Amano; T Furukawa; T Shirai; K Noda
Journal:  Br J Radiol       Date:  2014-12-23       Impact factor: 3.039

6.  An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images.

Authors:  Pankaj Mishra; Ruijiang Li; Raymond H Mak; Joerg Rottmann; Jonathan H Bryant; Christopher L Williams; Ross I Berbeco; John H Lewis
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

7.  Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing.

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Zdenka Kuncic; Paul J Keall
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

8.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

10.  Robust fluoroscopic tracking of fiducial markers: exploiting the spatial constraints.

Authors:  Rui Li; Gregory Sharp
Journal:  Phys Med Biol       Date:  2013-02-26       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.