Literature DB >> 20578867

Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography.

Mona Mohamed Salah Fayed1, Pawel Pazera, Christos Katsaros.   

Abstract

OBJECTIVES: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements.
MATERIAL AND METHODS: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses.
RESULTS: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible.
CONCLUSIONS: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20578867      PMCID: PMC8939012          DOI: 10.2319/121009-709.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  21 in total

1.  Forced eruption with microscrew anchorage for preprosthetic leveling of the gingival margin. Case report.

Authors:  Anke Roth; Murat Yildirim; Peter Diedrich
Journal:  J Orofac Orthop       Date:  2004-11       Impact factor: 1.938

2.  Mini-implants: Where are we?

Authors:  Birte Melsen
Journal:  J Clin Orthod       Date:  2005-09

3.  Implants in orthodontics. Interview.

Authors:  Aldo Carano; Birte Melsen
Journal:  Prog Orthod       Date:  2005       Impact factor: 2.750

4.  Group distal movement of teeth using microscrew implant anchorage.

Authors:  Hyo-Sang Park; Soo-Kyung Lee; Oh-Won Kwon
Journal:  Angle Orthod       Date:  2005-07       Impact factor: 2.079

5.  Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants.

Authors:  Toru Deguchi; Miho Nasu; Kaoru Murakami; Toshinori Yabuuchi; Hiroshi Kamioka; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-06       Impact factor: 2.650

6.  Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography.

Authors:  Seong-Hun Kim; Hyeong-Gun Yoon; Yong-Suk Choi; Eui-Hwan Hwang; Yoon-Ah Kook; Gerald Nelson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-05       Impact factor: 2.650

7.  Relationships between dental roots and surrounding tissues for orthodontic miniscrew installation.

Authors:  Kyung-Seok Hu; Min-Kyu Kang; Tae-Won Kim; Kyung-Ho Kim; Hee-Jin Kim
Journal:  Angle Orthod       Date:  2009-01       Impact factor: 2.079

8.  Mini-implant for orthodontic anchorage.

Authors:  R Kanomi
Journal:  J Clin Orthod       Date:  1997-11

9.  Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults.

Authors:  Joorok Park; Heon Jae Cho
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-09       Impact factor: 2.650

10.  Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants.

Authors:  Cristiane Monnerat; Luciana Restle; José Nelson Mucha
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-04       Impact factor: 2.650

View more
  29 in total

1.  Evaluating miniscrew position using orthopantomograms compared to cone-beam computed tomography.

Authors:  Ruth Bennemann; Martin Baxmann; Ludger Keilig; Susanne Reimann; Bert Braumann; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2012-05-12       Impact factor: 1.938

2.  Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography.

Authors:  Nattida Khumsarn; Virush Patanaporn; Apirum Janhom; Dhirawat Jotikasthira
Journal:  Imaging Sci Dent       Date:  2016-06-23

3.  A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition.

Authors:  Mayur S Bhattad; Sudhindra Baliga; Pavan Vibhute
Journal:  Dental Press J Orthod       Date:  2015 Mar-Apr

4.  Pulpal anesthesia in pediatric patients following supplemental mandibular buccal infiltration in vital permanent mandibular molars with deep caries.

Authors:  Papimon Chompu-Inwai; Puangporn Bua-On; Areerat Nirunsittirat; Patchanee Chuveera; Phumisak Louwakul; Thanapat Sastraruji
Journal:  Clin Oral Investig       Date:  2019-07-03       Impact factor: 3.573

5.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

6.  3-D Evaluation of temporary skeletal anchorage sites in the maxilla.

Authors:  Humberto Zago; Ricardo-de Lima Navarro; Vinicius Laranjeira; Thais-Maria-Freire Fernandes; Ana-Cláudia-de Castro-Ferreira Conti; Paula-Vanessa-Pedron Oltramari
Journal:  J Clin Exp Dent       Date:  2021-11-01

7.  Anatomical study of the maxillary tuberosity using cone beam computed tomography.

Authors:  Ester Manzanera; Paula Llorca; David Manzanera; Verónica García-Sanz; Vicente Sada; Vanessa Paredes-Gallardo
Journal:  Oral Radiol       Date:  2017-04-06       Impact factor: 1.852

8.  An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.

Authors:  Morten G Laursen; Birte Melsen; Paolo M Cattaneo
Journal:  Angle Orthod       Date:  2012-08-27       Impact factor: 2.079

9.  Cone-Beam Computed Tomographic Assessment of Bone Thickness in the Mandibular Anterior Region for Application of Orthodontic Mini-Screws.

Authors:  Majid Shalchi; Zahra Dalili Kajan; Mohammad Shabani; Negar Khosravifard; Samar Khabbaz; Farnoosh Khaksari
Journal:  Turk J Orthod       Date:  2021-06

10.  Inferior alveolar nerve canal position among South Indians: A cone beam computed tomographic pilot study.

Authors:  S M Balaji; N R Krishnaswamy; S Manoj Kumar; Thavarajah Rooban
Journal:  Ann Maxillofac Surg       Date:  2012-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.