Literature DB >> 18698651

Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement.

Ju-Eun Lim1, Won Hee Lim, Yoon Sic Chun.   

Abstract

Few studies have evaluated interradicular anatomy for cortical bone thickness and root proximity when placing a mini-implant for orthodontic anchorage. The purpose of this study was to provide a clinical guideline to indicate the best location, according to different insertion angles, for placement of a mini-implant with respect to the thickness of cortical bone and root proximity. CT images from 14 men and 14 women (mean age, 27 years; range, 23-35 years) were used to evaluate the buccal interradicular cortical bone thickness and root proximity from and mesial to the central incisor to the second molar. A measure of cortical bone thickness was performed at four different angles. Generally, thin cortical bone thickness was found in the central/central incisors and central/lateral incisors interradicular sites. Cortical bone thickness increased significantly as the insertion angle increased except for interradicular sites at the 2 mm level from the alveolar crest. The volume of cortical bone engagement increased significantly at the 4 and 6 mm levels from the alveolar crest with an insertion angle of 30 degrees and 45 degrees in most interradicular sites. The lateral incisor/canine and second premolar/first molar interradicular sites showed greater space between roots compared with other sites, although this was not statistically significant. Based on the findings of this study, we recommend that mini-implants be placed at the 4 and 6 mm levels from the alveolar crest with 30 degrees and 45 degrees angles for the majority of interradicular sites to ensure better cortical bone to mini-implant contact without root damage. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18698651     DOI: 10.1002/ca.20671

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  8 in total

1.  Evaluating miniscrew position using orthopantomograms compared to cone-beam computed tomography.

Authors:  Ruth Bennemann; Martin Baxmann; Ludger Keilig; Susanne Reimann; Bert Braumann; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2012-05-12       Impact factor: 1.938

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  Alveolar bone loss around incisors in Class I bidentoalveolar protrusion patients: a retrospective three-dimensional cone beam CT study.

Authors:  K-Y Nahm; J-H Kang; S-C Moon; Y-S Choi; Y-A Kook; S-H Kim; Jc Huang
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

4.  Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography.

Authors:  Mona A Abbassy; Hanady M Sabban; Ali H Hassan; Khalid H Zawawi
Journal:  Saudi Med J       Date:  2015-11       Impact factor: 1.484

5.  Can cone beam CT predict the hardness of interradicular cortical bone?

Authors:  Tamar Brosh; Bereznyak-Elias Yekaterina; Raphael Pilo; Nir Shpack; Silvia Geron
Journal:  Head Face Med       Date:  2014-04-15       Impact factor: 2.151

6.  Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing.

Authors:  Yu-Tzu Wang; Jian-Hong Yu; Lun-Jou Lo; Pin-Hsin Hsu; CHun-Li Lin
Journal:  Biomed Res Int       Date:  2017-02-09       Impact factor: 3.411

Review 7.  Buccal Bone Thickness in Anterior and Posterior Teeth-A Systematic Review.

Authors:  Diana Heimes; Eik Schiegnitz; Robert Kuchen; Peer W Kämmerer; Bilal Al-Nawas
Journal:  Healthcare (Basel)       Date:  2021-11-30

8.  Effect of miniscrew insertion angle in the maxillary buccal plate on its clinical survival: a randomized clinical trial.

Authors:  Amin Golshah; Kimia Gorji; Nafiseh Nikkerdar
Journal:  Prog Orthod       Date:  2021-08-02       Impact factor: 2.750

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.