Literature DB >> 28190152

Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Franz Sebastian Schwindling1, Franziska Lehmann2, Sophia Terebesi3, Nicoleta Corcodel3, Andreas Zenthöfer3, Peter Rammelsberg3, Thomas Stober3.   

Abstract

OBJECTIVE: The objective of the study was to investigate the clinical outcome for electroplated telescopic removable dental prostheses (E-RDPs) with zirconia primary crowns.
MATERIALS AND METHODS: Sixty E-RDPs, with primary crowns manufactured from either cobalt-chromium alloy or zirconia, were fabricated for 56 participants. Electroplating was used to produce gold copings directly on the telescopic primary crowns. These copings were bonded intra-orally to the prosthesis framework. After 36 months, prosthesis survival and number of complications were assessed. Statistical analysis was performed by the use of Kaplan-Meier modeling and the log-rank test.
RESULTS: Survival of the E-RDPs, 96.4% after 3 years, was identical in both groups. The need for aftercare was high but not significantly different: technical complications were observed for 37% and 42.9% of the prostheses for the zirconia and cobalt-chromium alloy primary crowns, respectively. Fracture of composite veneer was the most frequent complication (59.1%). The incidence of fractured abutment teeth, decementation, and endodontic problems was 7.9% in the zirconia group and 14% in the control group. The majority of abutment-level complications were treated restoratively. A significant difference was found for maximum probing depth at the abutment teeth: In the zirconia group, it decreased by 0.2 mm, whereas it increased by 0.8 mm in the control group (p = 0.04).
CONCLUSIONS: After 3 years of observation, survival of zirconia E-RDPs was favorable and comparable with that of established double-crown-retained prostheses. Further studies must clarify whether there are benefits of zirconia primary crowns for periodontal health. CLINICAL RELEVANCE: Although these results encourage the use of zirconia primary crowns, more research is necessary to reduce the number of complications observed for secondary telescopic crowns, for example, failure of the veneer.

Entities:  

Keywords:  Cobalt–chromium; Electroplating; Prosthetic dentistry; Removable dental prostheses; Zirconia

Mesh:

Substances:

Year:  2017        PMID: 28190152     DOI: 10.1007/s00784-017-2067-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  27 in total

1.  Analysis of veneer failure of removable prosthodontics.

Authors:  Sebastian Hahnel; Ralf Bürgers; Martin Rosentritt; Gerhard Handel; Michael Behr
Journal:  Gerodontology       Date:  2010-11-05       Impact factor: 2.980

2.  [Galvano-outer telescope by direct technique].

Authors:  G Diedrichs; P Rosenhain
Journal:  Quintessenz       Date:  1991-01

3.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

4.  Retention and surface changes of zirconia primary crowns with secondary crowns of different materials.

Authors:  Işıl Turp; Ergün Bozdağ; Emin Sünbüloğlu; Cem Kahruman; Ibrahim Yusufoğlu; Gülsen Bayraktar
Journal:  Clin Oral Investig       Date:  2014-01-31       Impact factor: 3.573

5.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

6.  Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance.

Authors:  Bernd Wöstmann; Markus Balkenhol; Andrea Weber; Paul Ferger; Peter Rehmann
Journal:  J Dent       Date:  2007-10-24       Impact factor: 4.379

7.  Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting.

Authors:  Mathew T Kattadiyil; Rami Jekki; Charles J Goodacre; Nadim Z Baba
Journal:  J Prosthet Dent       Date:  2015-09-26       Impact factor: 3.426

8.  Retention behavior of double-crown attachments with zirconia primary and secondary crowns.

Authors:  Franz Sebastian Schwindling; Thomas Stober; Rainer Rustemeier; Marc Schmitter; Stefan Rues
Journal:  Dent Mater       Date:  2016-03-26       Impact factor: 5.304

9.  Use of ceria-stabilized zirconia/alumina nanocomposite for fabricating the frameworks of removable dental prostheses: A clinical report.

Authors:  Yoshiyuki Hagiwara; Kiyoshi Nakajima
Journal:  J Prosthet Dent       Date:  2016-03-30       Impact factor: 3.426

10.  Does removable partial denture quality affect individuals' oral health?

Authors:  M Inukai; K Baba; M T John; Y Igarashi
Journal:  J Dent Res       Date:  2008-08       Impact factor: 6.116

View more
  2 in total

1.  Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation.

Authors:  Malin Strasding; Samir Abou-Ayash; Thomas Laziok; Sam Doerken; Ralf-Joachim Kohal; Sebastian Berthold Maximilian Patzelt
Journal:  Materials (Basel)       Date:  2022-09-04       Impact factor: 3.748

Review 2.  Telescopic Denture.

Authors:  Mohammad Ayham Hakkoum; Ghassan Wazir
Journal:  Open Dent J       Date:  2018-03-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.