Literature DB >> 22563821

An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

O A Peters1, A K Gluskin, R A Weiss, J T Han.   

Abstract

AIM: To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy.
METHODOLOGY: The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90°, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis.
RESULTS: Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle.
CONCLUSIONS: Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions.
© 2012 International Endodontic Journal.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22563821     DOI: 10.1111/j.1365-2591.2012.02067.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  21 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

2.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

3.  Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

Authors:  Amr Elnaghy; Shaymaa Elsaka
Journal:  Clin Oral Investig       Date:  2017-10-13       Impact factor: 3.573

4.  Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Authors:  Murilo Priori Alcalde; Marco Antonio Hungaro Duarte; Clovis Monteiro Bramante; Bruno Carvalho de Vasconselos; Mario Tanomaru-Filho; Juliane Maria Guerreiro-Tanomaru; Jader Camilo Pinto; Marcus Vinicius Reis Só; Rodrigo Ricci Vivan
Journal:  Clin Oral Investig       Date:  2017-12-09       Impact factor: 3.573

5.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

6.  Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals.

Authors:  Taha Özyürek; Mustafa Gündoğar; Gülşah Uslu; Koray Yılmaz; Simone Staffoli; Grande Nm; Gianluca Plotino; Antonella Polimeni
Journal:  Odontology       Date:  2018-01-30       Impact factor: 2.634

7.  Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties.

Authors:  Claudio Poggio; Alberto Dagna; Marco Chiesa; Riccardo Beltrami; Stefano Bianchi
Journal:  J Funct Biomater       Date:  2015-02-16

8.  Effect of dry cryogenic treatment on Vickers hardness and wear resistance of new martensitic shape memory nickel-titanium alloy.

Authors:  Thilla Sekar Vinothkumar; Deivanayagam Kandaswamy; Gopalakrishnan Prabhakaran; Arunachalam Rajadurai
Journal:  Eur J Dent       Date:  2015 Oct-Dec

Review 9.  Advances in endodontics: Potential applications in clinical practice.

Authors:  Anil Kishen; Ove A Peters; Matthias Zehnder; Anibal R Diogenes; Madhu K Nair
Journal:  J Conserv Dent       Date:  2016 May-Jun

10.  Mechanical behavior of deep cryogenically treated martensitic shape memory nickel-titanium rotary endodontic instruments.

Authors:  Thilla Sekar Vinothkumar; Deivanayagam Kandaswamy; Gopalakrishnan Prabhakaran; Arunachalam Rajadurai
Journal:  Eur J Dent       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.