Literature DB >> 22529077

The double-mobility acetabular component in revision total hip replacement: the United Kingdom experience.

N L Vasukutty1, R G Middleton, E C Matthews, P S Young, C E Uzoigwe, T H A Minhas.   

Abstract

We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction.

Entities:  

Mesh:

Year:  2012        PMID: 22529077     DOI: 10.1302/0301-620X.94B5.27876

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

1.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

Review 2.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

3.  Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

Authors:  Justinas Stucinskas; Tomas Kalvaitis; Alfredas Smailys; Otto Robertsson; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2017-12-02       Impact factor: 3.075

4.  Dual mobility constructs in revision total hip arthroplasty: survivorship analysis in recurrent dislocation versus other indications at three to twelve-year follow-up.

Authors:  Nicolas de l'Escalopier; Valérie Dumaine; Guillaume Auberger; Antoine Babinet; Jean-Pierre Courpied; Philippe Anract; Moussa Hamadouche
Journal:  Int Orthop       Date:  2019-11-22       Impact factor: 3.075

5.  Otto Aufranc Award: Dual-mobility Constructs in Revision THA Reduced Dislocation, Rerevision, and Reoperation Compared With Large Femoral Heads.

Authors:  Molly A Hartzler; Matthew P Abdel; Peter K Sculco; Michael J Taunton; Mark W Pagnano; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

6.  Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

Authors:  Alexandre Terrier; Adeliya Latypova; Maika Guillemin; Valérie Parvex; Olivier Guyen
Journal:  Int Orthop       Date:  2017-01-09       Impact factor: 3.075

7.  A double mobility acetabular implant for primary hip arthroplasty in patients at high risk of dislocation.

Authors:  N L Vasukutty; R G Middleton; P Young; C Uzoigwe; B Barkham; S Yusoff; T H A Minhas
Journal:  Ann R Coll Surg Engl       Date:  2014-11       Impact factor: 1.891

8.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups.

Authors:  Chahine Assi; Jacques Caton; Wissam Fawaz; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2018-10-29       Impact factor: 3.075

10.  Cementless dual-mobility cup in total hip arthroplasty revision.

Authors:  Jean Louis Prudhon; François Steffann; André Ferreira; Régis Verdier; Thierry Aslanian; Jacques Caton
Journal:  Int Orthop       Date:  2014-07-31       Impact factor: 3.075

View more