Internal calibration for opportunistic computed tomography muscle density analysis.

Ainsley C J Smith1,2,3, Justin J Tse2,3, Tadiwa H Waungana1,2,3, Kirsten N Bott2,3, Michael T Kuczynski1,2,3, Andrew S Michalski1,2,3, Steven K Boyd1,2,3, Sarah L Manske1,2,3.   

Abstract

INTRODUCTION: Muscle weakness can lead to reduced physical function and quality of life. Computed tomography (CT) can be used to assess muscle health through measures of muscle cross-sectional area and density loss associated with fat infiltration. However, there are limited opportunities to measure muscle density in clinically acquired CT scans because a density calibration phantom, allowing for the conversion of CT Hounsfield units into density, is typically not included within the field-of-view. For bone density analysis, internal density calibration methods use regions of interest within the scan field-of-view to derive the relationship between Hounsfield units and bone density, but these methods have yet to be adapted for muscle density analysis. The objective of this study was to design and validate a CT internal calibration method for muscle density analysis.
METHODOLOGY: We CT scanned 10 bovine muscle samples using two scan protocols and five scan positions within the scanner bore. The scans were calibrated using internal calibration and a reference phantom. We tested combinations of internal calibration regions of interest (e.g., air, blood, bone, muscle, adipose).
RESULTS: We found that the internal calibration method using two regions of interest, air and adipose or blood, yielded accurate muscle density values (< 1% error) when compared with the reference phantom. The muscle density values derived from the internal and reference phantom calibration methods were highly correlated (R2 > 0.99). The coefficient of variation for muscle density across two scan protocols and five scan positions was significantly lower for internal calibration (mean = 0.33%) than for Hounsfield units (mean = 6.52%). There was no difference between coefficient of variation for the internal calibration and reference phantom methods.
CONCLUSIONS: We have developed an internal calibration method to produce accurate and reliable muscle density measures from opportunistic computed tomography images without the need for calibration phantoms.

Entities:  

Mesh:

Year:  2022        PMID: 36251648      PMCID: PMC9576101          DOI: 10.1371/journal.pone.0273203

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.752


  46 in total

1.  Renal cyst pseudoenhancement: beam-hardening effects on CT numbers.

Authors:  D D Maki; B A Birnbaum; D P Chakraborty; J E Jacobs; B M Carvalho; G T Herman
Journal:  Radiology       Date:  1999-11       Impact factor: 11.105

2.  Development of a Skeletal Muscle Mimic Phantom Compatible with QCT and MR Imaging.

Authors:  Andy Kin On Wong; Zamir Merali; Jonathan D Adachi
Journal:  J Med Imaging Radiat Sci       Date:  2015-01-31

Review 3.  Clinical definition of sarcopenia.

Authors:  Valter Santilli; Andrea Bernetti; Massimiliano Mangone; Marco Paoloni
Journal:  Clin Cases Miner Bone Metab       Date:  2014-09

4.  Effects of patient size on radiation dose reduction and image quality in low-kVp CT pulmonary angiography performed with reduced IV contrast dose.

Authors:  Aaron Sodickson; Michael Weiss
Journal:  Emerg Radiol       Date:  2012-04-24

5.  Muscle Density, but Not Size, Correlates Well With Muscle Strength and Physical Performance.

Authors:  Ling Wang; Lu Yin; Yue Zhao; Yongbin Su; Wei Sun; Shuo Chen; Yandong Liu; Minghui Yang; Aihong Yu; Giuseppe Guglielmi; Glen M Blake; Xiaoguang Cheng; Xinbao Wu; Annegreet G Veldhuis-Vlug; Klaus Engelke
Journal:  J Am Med Dir Assoc       Date:  2020-08-05       Impact factor: 4.669

6.  Preoperative skeletal muscle density is associated with postoperative mortality in patients with cardiovascular disease.

Authors:  Masashi Yamashita; Kentaro Kamiya; Atsuhiko Matsunaga; Tadashi Kitamura; Nobuaki Hamazaki; Ryota Matsuzawa; Kohei Nozaki; Takafumi Ichikawa; Takeshi Nakamura; Shohei Yamamoto; Hidenori Kariya; Emi Maekawa; Kentaro Meguro; Misao Ogura; Minako Yamaoka-Tojo; Junya Ako; Kagami Miyaji
Journal:  Interact Cardiovasc Thorac Surg       Date:  2020-04-01

7.  The Design of SimpleITK.

Authors:  Bradley C Lowekamp; David T Chen; Luis Ibáñez; Daniel Blezek
Journal:  Front Neuroinform       Date:  2013-12-30       Impact factor: 4.081

Review 8.  Quantitative analysis of skeletal muscle by computed tomography imaging-State of the art.

Authors:  Klaus Engelke; Oleg Museyko; Ling Wang; Jean-Denis Laredo
Journal:  J Orthop Translat       Date:  2018-10-28       Impact factor: 5.191

9.  Low skeletal muscle radiodensity is the best predictor for short-term major surgical complications in gastrointestinal surgical cancer: A cohort study.

Authors:  Ana Lúcia Miranda de Carvalho; Maria Cristina Gonzalez; Iasmin Matias de Sousa; Isabel Pinto Amorim das Virgens; Galtieri Otavio Cunha de Medeiros; Marília Nelo Oliveira; Jeane Cristina Alves de Souza Dantas; Ana Paula Trussardi Fayh
Journal:  PLoS One       Date:  2021-02-19       Impact factor: 3.240

10.  Features of trunk muscle wasting during acute care and physical function recovery with aortic disease.

Authors:  Masashi Yamashita; Kentaro Kamiya; Atsuhiko Matsunaga; Tadashi Kitamura; Nobuaki Hamazaki; Takafumi Ichikawa; Shota Uchida; Takumi Noda; Naoya Yanagi; Emi Maekawa; Minako Yamaoka-Tojo; Junya Ako; Kagami Miyaji
Journal:  J Cachexia Sarcopenia Muscle       Date:  2022-02-17       Impact factor: 12.910

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.