Literature DB >> 24993583

High pitch, low voltage dual source CT pulmonary angiography: assessment of image quality and diagnostic acceptability with hybrid iterative reconstruction.

Patrick D McLaughlin1, T Liang, M Homiedan, L J Louis, T W O'Connell, Karl Krzymyk, S Nicolaou, J R Mayo.   

Abstract

Increased use of CT Pulmonary angiography in suspected pulmonary embolism (PE) has driven research to minimize radiation dose while maintaining image quality and diagnostic accuracy. Following institutional review board approval, we performed a retrospective comparison study in patients with suspected PE. Patients were scanned using an ultra high pitch dual source technique (pitch = 2.6) using 120 kV (SVCTPA) (n = 54) or 100 kV (RV-CTPA) (n = 52). SV-CTPA images were reconstructed using filtered back projection (SV-wFBP) and RV-CTPA images were reconstructed using both FBP (RV-wFBP) and Iterative Reconstruction (RV-IR). Comparison of radiation dose, diagnostic ability, subjective image noise, quality, and sharpness, diagnostic agreement, signal to noise (SNR) and contrast to noise ratios (CNR) were performed. Mean effective dose was 2.56 ± 0.19 mSv for the RV protocol compared to 5.36 ± 0.60 mSv for the SV. The RV-CTPA protocol resulted in a mean DLP reduction of 52 % and mean CTDI reduction of 51 %. Pulmonary artery SNR and CNR were significantly higher on RV-IR images than SV-wFBP (p = 0.007, p = 0.003). Mean subjective image noise, quality and sharpness scores did not differ significantly between the SV-wFBP and RVIR images (p > 0.05). Subjective quality scores were significantly better for the RV-IR group compared to the RV-wFBP group (p < 0.001). Agreement between readers for presence or absence of pulmonary emboli on RV-IR images was almost perfect (κ = 0.891, p < 0.001). Iterative reconstruction complements ultra high pitch dual source CTPA examinations acquired using a reduced voltage resulting in higher mean pulmonary artery SNR and CNR when compared to both RV-wFBP and SV-CTPA.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24993583     DOI: 10.1007/s10140-014-1230-4

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  23 in total

1.  Acute chest pain--suspected pulmonary embolism. American College of Radiology. ACR Appropriateness Criteria.

Authors:  M A Bettmann; L M Boxt; A S Gomes; J Grollman; R E Henkin; C B Higgins; M J Kelley; L Needleman; H Pagan-Marin; J F Polak; W Stanford; W Ashburn
Journal:  Radiology       Date:  2000-06       Impact factor: 11.105

2.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

3.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

4.  Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

Authors:  Daniel Cornfeld; Gary Israel; Ezra Detroy; Jamal Bokhari; Hamid Mojibian
Journal:  AJR Am J Roentgenol       Date:  2011-03       Impact factor: 3.959

5.  Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom.

Authors:  Jijo Paul; B Krauss; R Banckwitz; W Maentele; R W Bauer; T J Vogl
Journal:  Eur J Radiol       Date:  2011-02-12       Impact factor: 3.528

6.  CT coronary angiography: image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection.

Authors:  R Wang; U J Schoepf; R Wu; K P Gibbs; W Yu; M Li; Z Zhang
Journal:  Clin Radiol       Date:  2012-09-13       Impact factor: 2.350

7.  A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction.

Authors:  Jonathon Leipsic; Giang Nguyen; Jaqueline Brown; Don Sin; John R Mayo
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

8.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

9.  Image quality and radiation dose of pulmonary CT angiography performed using 100 and 120 kVp.

Authors:  Randy Fanous; Hany Kashani; Laura Jimenez; Grainne Murphy; Narinder S Paul
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

10.  The yield of CT pulmonary angiograms to exclude acute pulmonary embolism.

Authors:  Andreu F Costa; Hamed Basseri; Adnan Sheikh; Ian Stiell; Carole Dennie
Journal:  Emerg Radiol       Date:  2013-11-02
View more
  9 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

Review 3.  Tailoring protocols for chest CT applications: when and how?

Authors:  Roberto Iezzi; Anna Rita Larici; Paola Franchi; Riccardo Marano; Nicola Magarelli; Alessandro Posa; Biagio Merlino; Riccardo Manfredi; Cesare Colosimo
Journal:  Diagn Interv Radiol       Date:  2017 Nov-Dec       Impact factor: 2.630

Review 4.  Dual-energy CT in pulmonary vascular disease.

Authors:  Ioannis Vlahos; Megan C Jacobsen; Myrna C Godoy; Konstantinos Stefanidis; Rick R Layman
Journal:  Br J Radiol       Date:  2021-09-24       Impact factor: 3.039

5.  Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral technique.

Authors:  Teresa Liang; Patrick McLaughlin; Chesnal D Arepalli; Luck J Louis; Ana-Maria Bilawich; John Mayo; Savvas Nicolaou
Journal:  Emerg Radiol       Date:  2015-12-04

6.  Patient-specific 3D printed pulmonary artery model with simulation of peripheral pulmonary embolism for developing optimal computed tomography pulmonary angiography protocols.

Authors:  Sultan Aldosari; Shirley Jansen; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-01

7.  High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population.

Authors:  Bastian O Sabel; Kristijan Buric; Nora Karara; Kolja M Thierfelder; Julien Dinkel; Wieland H Sommer; Felix G Meinel
Journal:  PLoS One       Date:  2016-02-12       Impact factor: 3.240

8.  Comparison of high-pitch prospective electrocardiogram-gated pulmonary CT angiography with standard CT pulmonary angiography on dual-source CT for detection of subsegmental pulmonary embolism in patients suspected of acute pulmonary embolism.

Authors:  Rohini Thakur; Manphool Singhal; Ashutosh Nath Aggrawal; Ujjwal Gorsi; Navneet Sharma; Ashish Bhalla; Niranjan Khandelwal
Journal:  Pol J Radiol       Date:  2022-05-31

Review 9.  Acute pulmonary embolism multimodality imaging prior to endovascular therapy.

Authors:  David Sin; Gordon McLennan; Fabian Rengier; Ihab Haddadin; Gustavo A Heresi; John R Bartholomew; Matthias A Fink; Dustin Thompson; Sasan Partovi
Journal:  Int J Cardiovasc Imaging       Date:  2020-08-30       Impact factor: 2.357

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.