Literature DB >> 21447451

A no-reference image blur metric based on the cumulative probability of blur detection (CPBD).

Niranjan D Narvekar, Lina J Karam.   

Abstract

This paper presents a no-reference image blur metric that is based on the study of human blur perception for varying contrast values. The metric utilizes a probabilistic model to estimate the probability of detecting blur at each edge in the image, and then the information is pooled by computing the cumulative probability of blur detection (CPBD). The performance of the metric is demonstrated by comparing it with existing no-reference sharpness/blurriness metrics for various publicly available image databases.

Entities:  

Year:  2011        PMID: 21447451     DOI: 10.1109/TIP.2011.2131660

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  10 in total

1.  Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Authors:  Giacomo Tarroni; Luca Tersi; Cristiana Corsi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-03-27       Impact factor: 2.602

2.  A Novel Semi-Autonomous Control Framework for Retina Confocal Endomicroscopy Scanning.

Authors:  Zhaoshuo Li; Mahya Shahbazi; Niravkumar Patel; Eimear O' Sullivan; Haojie Zhang; Khushi Vyas; Preetham Chalasani; Peter L Gehlbach; Iulian Iordachita; Guang-Zhong Yang; Russell H Taylor
Journal:  Rep U S       Date:  2020-01-27

3.  Low Complexity Image Quality Measures for Dietary Assessment Using Mobile Devices.

Authors:  Chang Xu; Nitin Khanna; Carol J Boushey; Edward J Delp
Journal:  ISM       Date:  2012-01-09

4.  Towards machine learned quality control: A benchmark for sharpness quantification in digital pathology.

Authors:  Gabriele Campanella; Arjun R Rajanna; Lorraine Corsale; Peter J Schüffler; Yukako Yagi; Thomas J Fuchs
Journal:  Comput Med Imaging Graph       Date:  2017-09-25       Impact factor: 7.422

5.  Filtering Based Adaptive Visual Odometry Sensor Framework Robust to Blurred Images.

Authors:  Haiying Zhao; Yong Liu; Xiaojia Xie; Yiyi Liao; Xixi Liu
Journal:  Sensors (Basel)       Date:  2016-07-05       Impact factor: 3.576

6.  A shallow convolutional neural network for blind image sharpness assessment.

Authors:  Shaode Yu; Shibin Wu; Lei Wang; Fan Jiang; Yaoqin Xie; Leida Li
Journal:  PLoS One       Date:  2017-05-01       Impact factor: 3.240

7.  Blind image blur assessment using singular value similarity and blur comparisons.

Authors:  Qing-Bing Sang; Xiao-Jun Wu; Chao-Feng Li; Yin Lu
Journal:  PLoS One       Date:  2014-09-23       Impact factor: 3.240

8.  Generative models: an upcoming innovation in musculoskeletal radiology? A preliminary test in spine imaging.

Authors:  Fabio Galbusera; Tito Bassani; Gloria Casaroli; Salvatore Gitto; Edoardo Zanchetta; Francesco Costa; Luca Maria Sconfienza
Journal:  Eur Radiol Exp       Date:  2018-10-31

9.  Application of Highly Flexible Adaptive Image Receive Coil for Lung MR Imaging Using Zero TE Sequence: Comparison with Conventional Anterior Array Coil.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Yunsub Jung; Joonsung Lee
Journal:  Diagnostics (Basel)       Date:  2022-01-08

10.  A Deconvolutional Deblurring Algorithm Based on Short- and Long-Exposure Images.

Authors:  Yang Bai; Zheng Tan; Qunbo Lv; Min Huang
Journal:  Sensors (Basel)       Date:  2022-02-25       Impact factor: 3.576

  10 in total