Literature DB >> 18218455

Image sequence filtering in quantum-limited noise with applications to low-dose fluoroscopy.

C L Chan1, A K Katsaggelos, A V Sahakian.   

Abstract

Clinical angiography requires hundreds of X-ray images, putting the patients and particularly the medical staff at risk. Dosage reduction involves an inevitable sacrifice in image quality. In this work, the latter problem is addressed by first modeling the signal-dependent, Poisson-distributed noise that arises as a result of this dosage reduction. The commonly utilized noise model for single images is shown to be obtainable from the new model. Stochastic temporal filtering techniques are proposed to enhance clinical fluoroscopy sequences corrupted by quantum mottle. The temporal versions of these filters as developed here are more suitable for filtering image sequences, as correlations along the time axis can be utilized. For these dynamic sequences, the problem of displacement field estimation is treated in conjunction with the filtering stage to ensure that the temporal correlations are taken along the direction of motion to prevent object blur.

Entities:  

Year:  1993        PMID: 18218455     DOI: 10.1109/42.241890

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  A CANDLE for a deeper in vivo insight.

Authors:  Pierrick Coupé; Martin Munz; Jose V Manjón; Edward S Ruthazer; D Louis Collins
Journal:  Med Image Anal       Date:  2012-01-18       Impact factor: 8.545

2.  Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Authors:  Giacomo Tarroni; Luca Tersi; Cristiana Corsi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-03-27       Impact factor: 2.602

3.  X-ray fluoroscopy noise modeling for filter design.

Authors:  M Cesarelli; P Bifulco; T Cerciello; M Romano; L Paura
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-21       Impact factor: 2.924

4.  Noise reduction for curve-linear structures in real time fluoroscopy applications using directional binary masks.

Authors:  Martin Wagner; Pengfei Yang; Sebastian Schafer; Charles Strother; Charles Mistretta
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

5.  A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system.

Authors:  Naoki Miyamoto; Masayori Ishikawa; Kenneth Sutherland; Ryusuke Suzuki; Taeko Matsuura; Chie Toramatsu; Seishin Takao; Hideaki Nihongi; Shinichi Shimizu; Kikuo Umegaki; Hiroki Shirato
Journal:  J Radiat Res       Date:  2014-08-16       Impact factor: 2.724

6.  A Modified BFGS Formula Using a Trust Region Model for Nonsmooth Convex Minimizations.

Authors:  Zengru Cui; Gonglin Yuan; Zhou Sheng; Wenjie Liu; Xiaoliang Wang; Xiabin Duan
Journal:  PLoS One       Date:  2015-10-26       Impact factor: 3.240

7.  Measurement of intervertebral cervical motion by means of dynamic x-ray image processing and data interpolation.

Authors:  Paolo Bifulco; Mario Cesarelli; Maria Romano; Antonio Fratini; Mario Sansone
Journal:  Int J Biomed Imaging       Date:  2013-10-31

8.  A hybrid conjugate gradient algorithm for constrained monotone equations with application in compressive sensing.

Authors:  Abdulkarim Hassan Ibrahim; Poom Kumam; Auwal Bala Abubakar; Wachirapong Jirakitpuwapat; Jamilu Abubakar
Journal:  Heliyon       Date:  2020-03-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.