Further exploration of MRI techniques for liver T1rho quantification.

Feng Zhao1, Jing Yuan2, Min Deng1, Pu-Xuan Lu3, Anil T Ahuja1, Yi-Xiang J Wang1.   

Abstract

With biliary duct ligation and CCl4 induced rat liver fibrosis models, recent studies showed that MR T1rho imaging is able to detect liver fibrosis, and the degree of fibrosis is correlated with the degree of elevation of the T1rho measurements, suggesting liver T1rho quantification may play an important role for liver fibrosis early detection and grading. It has also been reported it is feasible to obtain consistent liver T1rho measurement for human subjects at 3 Tesla (3 T), and preliminary clinical data suggest liver T1rho is increased in patients with cirrhosis. In these previous studies, T1rho imaging was used with the rotary-echo spin-lock pulse for T1rho preparation, and number of signal averaging (NSA) was 2. Due to the presence of inhomogeneous B0 field, artifacts may occur in the acquired T1rho-weighted images. The method described by Dixon et al. (Magn Reson Med 1996;36:90-4), which is a hard RF pulse with 135° flip angle and same RF phase as the spin-locking RF pulse is inserted right before and after the spin-locking RF pulse, has been proposed to reduce sensitivity to B0 field inhomogeneity in T1rho imaging. In this study, we compared the images scanned by rotary-echo spin-lock pulse method (sequence 1) and the pulse modified according to Dixon method (sequence 2). When the artifacts occurred in T1rho images, we repeated the same scan until satisfactory. We accepted images if artifact in liver was less than 10% of liver area by visual estimation. When NSA =2, the breath-holding duration for data acquisition of one slice scanning was 8 sec due to a delay time of 6,000 ms for magnetization restoration. If NSA =1, the duration was shortened to be 2 sec. In previous studies, manual region of interest (ROI) analysis of T1rho map was used. In this current study, histogram analysis was also applied to evaluate liver T1rho value on T1rho maps. MRI data acquisition was performed on a 3 T clinical scanner. There were 29 subjects with 61 examinations obtained. Liver T1rho values obtained by sequence 1 (NSA =2) and sequence 2 (NSA =2) showed similar values, i.e., 43.1±2.1 ms (range: 38.6-48.0 ms, n=40 scans) vs. 43.5±2.5 ms (range: 39.0-47.7 ms, 
n=12 scans, P=0.74) respectively. For the six volunteers scanned with both sequences in one session, the intraclass correlation coefficient (ICC) was 0.939. Overall, the success rate of obtaining satisfactory images per acquisition was slightly over 50% for both sequence 1 and sequence 2. Satisfactory images can usually be obtained by asking the volunteer subjects to better hold their breath. However, sequence 2 did not increase the scan success rate. For the nine subjects scanned by sequence 2 with both NSA =2 and NSA =1 during one session, the ICC was 0.274, demonstrated poor agreement. T1rho measurement by ROI method and histogram had an ICC of 0.901 (P>0.05), demonstrated very good agreement. We conclude that by including 135° flip angle before and after the spin-locking RF pulse, the rate of artifacts occurring did not decrease. On the other hand, sequence 1 and sequence 2 measured similar T1rho value in healthy liver. While reducing the breath-holding duration significantly, NSA =1 did not offer satisfactory signal-to-noise ratio. Histogram measurement can be adopted for future studies.

Entities:  

Keywords:  Magnetic resonance imaging; T1rho; liver; quantification

Year:  2013        PMID: 24404445      PMCID: PMC3882805          DOI: 10.3978/j.issn.2223-4292.2013.12.10

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  18 in total

Review 1.  Liver biopsy.

Authors:  A A Bravo; S G Sheth; S Chopra
Journal:  N Engl J Med       Date:  2001-02-15       Impact factor: 91.245

2.  Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence.

Authors:  M Deng; F Zhao; J Yuan; A T Ahuja; Y-X J Wang
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

3.  Myocardial suppression in vivo by spin locking with composite pulses.

Authors:  W T Dixon; J N Oshinski; J D Trudeau; B C Arnold; R I Pettigrew
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

4.  Liver fibrosis: noninvasive diagnosis with double contrast material-enhanced MR imaging.

Authors:  Diego A Aguirre; Cynthia A Behling; Elliot Alpert; Tarek I Hassanein; Claude B Sirlin
Journal:  Radiology       Date:  2006-05       Impact factor: 11.105

5.  The role of laparoscopy in the diagnosis of cirrhosis.

Authors:  J Poniachik; D E Bernstein; K R Reddy; L J Jeffers; M E Coelho-Little; F Civantos; E R Schiff
Journal:  Gastrointest Endosc       Date:  1996-06       Impact factor: 9.427

Review 6.  Reversal of hepatic fibrosis -- fact or fantasy?

Authors:  Scott L Friedman; Meena B Bansal
Journal:  Hepatology       Date:  2006-02       Impact factor: 17.425

7.  T1rho MR imaging is sensitive to evaluate liver fibrosis: an experimental study in a rat biliary duct ligation model.

Authors:  Yi-Xiang J Wang; Jing Yuan; Eagle S H Chu; Minnie Y Y Go; Hua Huang; Anil T Ahuja; Joseph J Y Sung; Jun Yu
Journal:  Radiology       Date:  2011-03-24       Impact factor: 11.105

8.  MR T1ρ as an imaging biomarker for monitoring liver injury progression and regression: an experimental study in rats with carbon tetrachloride intoxication.

Authors:  Feng Zhao; Yi-Xiang J Wang; Jing Yuan; Min Deng; Hing Lok Wong; Eagle S H Chu; Minnie Y Y Go; Gao-Jun Teng; Anil T Ahuja; Jun Yu
Journal:  Eur Radiol       Date:  2012-03-27       Impact factor: 5.315

Review 9.  MR imaging of liver fibrosis: current state of the art.

Authors:  Silvana C Faria; Karthik Ganesan; Irene Mwangi; Masoud Shiehmorteza; Barbara Viamonte; Sameer Mazhar; Michael Peterson; Yuko Kono; Cynthia Santillan; Giovanna Casola; Claude B Sirlin
Journal:  Radiographics       Date:  2009-10       Impact factor: 5.333

10.  Experimental evaluation of accelerated T1rho relaxation quantification in human liver using limited spin-lock times.

Authors:  Feng Zhao; Min Deng; Jing Yuan; Gao-Jun Teng; Anil T Ahuja; Yi-Xiang J Wang
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

View more
  8 in total

Review 1.  [Modern magnetic resonance imaging of the liver].

Authors:  D M Hedderich; K Weiss; D Maintz; T Persigehl
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

2.  Evaluation of liver fibrosis with T1ρ MR imaging.

Authors:  Yi-Xiang J Wang; Jing Yuan
Journal:  Quant Imaging Med Surg       Date:  2014-06

3.  Chemical Exchange Saturation Transfer (CEST) MR Technique for Liver Imaging at 3.0 Tesla: an Evaluation of Different Offset Number and an After-Meal and Over-Night-Fast Comparison.

Authors:  Min Deng; Shu-Zhong Chen; Jing Yuan; Queenie Chan; Jinyuan Zhou; Yì-Xiáng J Wáng
Journal:  Mol Imaging Biol       Date:  2016-04       Impact factor: 3.488

4.  Black blood T1rho MR imaging may diagnose early stage liver fibrosis: a proof-of-principle study with rat biliary duct ligation model.

Authors:  Chi-Man Koon; Xin Zhang; Weitian Chen; Eagle Siu Hong Chu; Clara Bik San Lau; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-08

Review 5.  T₁ρ MRI of human musculoskeletal system.

Authors:  Ligong Wang; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

6.  Chemical exchange saturation transfer (CEST) MR technique for in-vivo liver imaging at 3.0 tesla.

Authors:  Shu-Zhong Chen; Jing Yuan; Min Deng; Juan Wei; Jinyuan Zhou; Yì-Xiáng J Wáng
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

7.  T1ρ relaxation time in brain regions increases with ageing: an experimental MRI observation in rats.

Authors:  Feng Zhao; Jing Yuan; Gang Lu; Li H Zhang; Zhi Y Chen; Yì-Xiáng J Wáng
Journal:  Br J Radiol       Date:  2015-11-03       Impact factor: 3.039

8.  Decreases in molecular diffusion, perfusion fraction and perfusion-related diffusion in fibrotic livers: a prospective clinical intravoxel incoherent motion MR imaging study.

Authors:  Pu-Xuan Lu; Hua Huang; Jing Yuan; Feng Zhao; Zhi-Yi Chen; Qinwei Zhang; Anil T Ahuja; Bo-Ping Zhou; Yì-Xiáng J Wáng
Journal:  PLoS One       Date:  2014-12-01       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.