Abstract

Conventional pacemakers and implantable cardioverter-defibrillators (ICD) have always been regarded as a contraindication to magnetic resonance imaging (MRI). MR-compatible systems represent a recent and particularly important innovation, since they will provide device patients with significantly improved access to MR examinations. However, the safe application of MR-compatible technology requires a detailed understanding of the strictly defined cardiologic and radiologic requirements and conditions that are to be adhered to before and during an MR examination. The present article gives an overview of problematic MR interactions with implanted devices, illustrates the most important aspects of MR-compatible pacemaker and ICD systems, analyzes their current clinical status, and offers a critical perspective.

Entities:  

Mesh:

Year:  2012        PMID: 22398815     DOI: 10.1007/s00059-012-3588-y

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  40 in total

1.  A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

Authors:  Peter Thomas Burke; Hamid Ghanbari; Patrick B Alexander; Michael K Shaw; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2010-01-29       Impact factor: 1.900

2.  Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI.

Authors:  Deborah A Langman; Ira B Goldberg; J Paul Finn; Daniel B Ennis
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

3.  Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices.

Authors:  Francisco Buendía; Óscar Cano; Juan Miguel Sánchez-Gómez; Begoña Igual; Joaquín Osca; María José Sancho-Tello; José Olagüe; Antonio Salvador
Journal:  Europace       Date:  2011-01-11       Impact factor: 5.214

4.  Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations.

Authors:  Torsten Sommer; Claas P Naehle; Alexander Yang; Volkert Zeijlemaker; Matthias Hackenbroch; Alexandra Schmiedel; Carsten Meyer; Katharina Strach; Dirk Skowasch; Christian Vahlhaus; Harold Litt; Hans Schild
Journal:  Circulation       Date:  2006-09-11       Impact factor: 29.690

Review 5.  Current clinical issues for MRI scanning of pacemaker and defibrillator patients.

Authors:  Ron Kalin; Marshall S Stanton
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

6.  Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs).

Authors:  J Rod Gimbel; Emanuel Kanal; Kerry M Schwartz; Bruce L Wilkoff
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

7.  Safety of serial MRI in patients with implantable cardioverter defibrillators.

Authors:  M Juhani Junttila; Joel E Fishman; Gustavo A Lopera; Pradip M Pattany; Darcy L Velazquez; Adam R Williams; Barry H Trachtenberg; Cristina Sanina; Jacques Mather; Joshua M Hare
Journal:  Heart       Date:  2011-08-26       Impact factor: 5.994

8.  Strategies for the safe magnetic resonance imaging of pacemaker-dependent patients.

Authors:  J Rod Gimbel; Shane M Bailey; Patrick J Tchou; Paul M Ruggieri; Bruce L Wilkoff
Journal:  Pacing Clin Electrophysiol       Date:  2005-10       Impact factor: 1.976

9.  Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

Authors:  Claas P Naehle; Katharina Strach; Daniel Thomas; Carsten Meyer; Markus Linhart; Sascha Bitaraf; Harold Litt; Jörg Otto Schwab; Hans Schild; Torsten Sommer
Journal:  J Am Coll Cardiol       Date:  2009-08-04       Impact factor: 24.094

10.  Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design.

Authors:  Richard Sutton; Emanuel Kanal; Bruce L Wilkoff; David Bello; Roger Luechinger; Inge Jenniskens; Michael Hull; Torsten Sommer
Journal:  Trials       Date:  2008-12-02       Impact factor: 2.279

View more
  2 in total

Review 1.  [Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations].

Authors:  M Dorenkamp; C Stromberger; C von Heymann; W Haverkamp; P Wust; M Roser
Journal:  Strahlenther Onkol       Date:  2012-11-11       Impact factor: 3.621

2.  DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices.

Authors:  Benjamin Gauter-Fleckenstein; Carsten W Israel; Marc Dorenkamp; Jürgen Dunst; Mattias Roser; Rainer Schimpf; Volker Steil; Jörg Schäfer; Ulrike Höller; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2015-03-05       Impact factor: 3.621

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.