Literature DB >> 15826257

Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs).

J Rod Gimbel1, Emanuel Kanal, Kerry M Schwartz, Bruce L Wilkoff.   

Abstract

OBJECTIVE: To determine if simple strategies used to safely scan pacemaker patients could be applied to implantable cardioverter defibrillator (ICD), patients undergoing MRI allowing ICD patients to undergo MRI as well.
INTERVENTIONS: Screening, reprogramming, and monitoring strategies were used to facilitate MRI.
RESULTS: Seven patients underwent eight MRI scans at 1.5 T. Post-MRI, all devices demonstrated no change in pacing, sensing, impedances, charge times, or battery status. The patient undergoing a lumbar spine scan experienced a "power-on-reset" of his ICD without permanent impairment of his device.
CONCLUSION: Scanning of ICD patients might be performed if appropriate reprogramming and monitoring is implemented.

Entities:  

Mesh:

Year:  2005        PMID: 15826257     DOI: 10.1111/j.1540-8159.2005.09520.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  17 in total

1.  [Magnetic resonance imaging and implantable cardiac devices. Current status and future perspectives of MR-compatible systems].

Authors:  M Dorenkamp; M Roser; B Hamm; W Haverkamp
Journal:  Herz       Date:  2012-03       Impact factor: 1.443

2.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  Circulation       Date:  2010-05-17       Impact factor: 29.690

3.  A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

Authors:  Peter Thomas Burke; Hamid Ghanbari; Patrick B Alexander; Michael K Shaw; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2010-01-29       Impact factor: 1.900

4.  Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective.

Authors:  M J W Götte; I K Rüssel; G J de Roest; T Germans; R F Veldkamp; P Knaapen; C P Allaart; A C van Rossum
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

Review 5.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  J Am Coll Cardiol       Date:  2010-06-08       Impact factor: 24.094

6.  An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

Authors:  Pierpaolo Lupo; Riccardo Cappato; Giovanni Di Leo; Francesco Secchi; Giacomo D E Papini; Sara Foresti; Hussam Ali; Guido M G De Ambroggi; Antonio Sorgente; Gianluca Epicoco; Paola M Cannaò; Francesco Sardanelli
Journal:  Eur Radiol       Date:  2018-01-09       Impact factor: 5.315

7.  Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study.

Authors:  Mrinal Yadava; Matthew Nugent; Angela Krebsbach; Jessica Minnier; Peter Jessel; Charles A Henrikson
Journal:  J Interv Card Electrophysiol       Date:  2017-07-22       Impact factor: 1.900

8.  Repeated MRI of a patient with an intramedullary tumour and implanted cardiac resynchronization therapy defibrillator (CRT-D).

Authors:  C Brockmann; T Sommer; R Pirzer; H U Kerl; I S Nolte; A Förster; M A Brockmann
Journal:  Clin Neuroradiol       Date:  2012-10-19       Impact factor: 3.649

9.  Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.

Authors:  Saman Nazarian; Rozann Hansford; Amir A Rahsepar; Valeria Weltin; Diana McVeigh; Esra Gucuk Ipek; Alan Kwan; Ronald D Berger; Hugh Calkins; Albert C Lardo; Michael A Kraut; Ihab R Kamel; Stefan L Zimmerman; Henry R Halperin
Journal:  N Engl J Med       Date:  2017-12-28       Impact factor: 91.245

10.  A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices.

Authors:  Saman Nazarian; Rozann Hansford; Ariel Roguin; Dorith Goldsher; Menekhem M Zviman; Albert C Lardo; Brian S Caffo; Kevin D Frick; Michael A Kraut; Ihab R Kamel; Hugh Calkins; Ronald D Berger; David A Bluemke; Henry R Halperin
Journal:  Ann Intern Med       Date:  2011-10-04       Impact factor: 25.391

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.