Literature DB >> 21873440

Safety of serial MRI in patients with implantable cardioverter defibrillators.

M Juhani Junttila1, Joel E Fishman, Gustavo A Lopera, Pradip M Pattany, Darcy L Velazquez, Adam R Williams, Barry H Trachtenberg, Cristina Sanina, Jacques Mather, Joshua M Hare.   

Abstract

OBJECTIVE: While patients with cardiac implantable electronic devices could benefit from magnetic resonance (MR) imaging, the presence of such devices has been designated as an absolute contraindication to MR. Although scanning algorithms are proposed for cardiac implantable electronic devices, their safety remains uncertain. To address this issue, the safety of serial cardiac MR scans was evaluated in patients with implantable cardioverter defibrillators (ICDs).
METHODS: Three serial cardiac MR scans were prospectively performed at 1.5 T on 10 patients (9 men) of median age 56 years (range 51-68) with ICDs. ICD interrogation was performed before and after the MR scan and at a follow-up of median 370 days (range 274-723). Image quality was also assessed.
RESULTS: In all patients MR scanning occurred without complications. There were no differences between pre- and post-MR pacing capture threshold, pacing lead or high voltage lead impedance, or battery voltage values. During follow-up there were no occurrences of ICD dysfunction. Although most patients had image artifacts, the studies were generally diagnostic regarding left ventricular function and wall motion. Delayed enhancement imaging was of good quality for inferior wall and inferolateral infarcts, but ICD artifacts often affected the imaging of anterior wall infarcts.
CONCLUSION: Serial MR scans at 1.5 T in patients with ICDs, when carefully performed in a monitored setting, have no adverse effects on either patient or device. When required, single or multiple MR scans at 1.5 T may therefore be considered for clinical diagnostic purposes in these patients.

Entities:  

Mesh:

Year:  2011        PMID: 21873440      PMCID: PMC3994993          DOI: 10.1136/heartjnl-2011-300153

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  12 in total

1.  Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

Authors:  Ariel Roguin; Menekhem M Zviman; Glenn R Meininger; E Rene Rodrigues; Timm M Dickfeld; David A Bluemke; Albert Lardo; Ronald D Berger; Hugh Calkins; Henry R Halperin
Journal:  Circulation       Date:  2004-07-26       Impact factor: 29.690

2.  Industry viewpoint: St. Jude Medical: Pacemakers, ICDs and MRI.

Authors:  Paul A Levine
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

3.  Industry viewpoint: Medtronic: Pacemakers, ICDs, and MRI.

Authors:  Marshall S Stanton
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

4.  Government viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRI.

Authors:  Owen P Faris; Mitchell J Shein
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

5.  Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients.

Authors:  Owen P Faris; Mitchell Shein
Journal:  Circulation       Date:  2006-09-19       Impact factor: 29.690

Review 6.  Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices.

Authors:  Ariel Roguin; Juerg Schwitter; Christian Vahlhaus; Massimo Lombardi; Josep Brugada; Panos Vardas; Angelo Auricchio; Silvia Priori; Torsten Sommer
Journal:  Europace       Date:  2008-03       Impact factor: 5.214

7.  ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.

Authors:  Andrew E Epstein; John P DiMarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Christopher E Buller; Mark A Creager; Steven M Ettinger; David P Faxon; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Harlan M Krumholz; Frederick G Kushner; Bruce W Lytle; Rick A Nishimura; Joseph P Ornato; Richard L Page; Barbara Riegel; Lynn G Tarkington; Clyde W Yancy
Journal:  J Am Coll Cardiol       Date:  2008-05-27       Impact factor: 24.094

Review 8.  Current clinical issues for MRI scanning of pacemaker and defibrillator patients.

Authors:  Ron Kalin; Marshall S Stanton
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

9.  Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Glenn N Levine; Antoinette S Gomes; Andrew E Arai; David A Bluemke; Scott D Flamm; Emanuel Kanal; Warren J Manning; Edward T Martin; J Michael Smith; Norbert Wilke; Frank S Shellock
Journal:  Circulation       Date:  2007-11-19       Impact factor: 29.690

10.  Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

Authors:  Claas P Naehle; Katharina Strach; Daniel Thomas; Carsten Meyer; Markus Linhart; Sascha Bitaraf; Harold Litt; Jörg Otto Schwab; Hans Schild; Torsten Sommer
Journal:  J Am Coll Cardiol       Date:  2009-08-04       Impact factor: 24.094

View more
  16 in total

1.  [Magnetic resonance imaging and implantable cardiac devices. Current status and future perspectives of MR-compatible systems].

Authors:  M Dorenkamp; M Roser; B Hamm; W Haverkamp
Journal:  Herz       Date:  2012-03       Impact factor: 1.443

Review 2.  The Assessment of Cardiac Masses by Cardiac CT and CMR Including Pre-op 3D Reconstruction and Planning.

Authors:  Stephen Liddy; Colin McQuade; Kevin P Walsh; Bryan Loo; Orla Buckley
Journal:  Curr Cardiol Rep       Date:  2019-07-31       Impact factor: 2.931

Review 3.  Safety of implanted cardiac devices in an MRI environment.

Authors:  Esra Gucuk Ipek; Saman Nazarian
Journal:  Curr Cardiol Rep       Date:  2015-07       Impact factor: 2.931

4.  Repeated MRI of a patient with an intramedullary tumour and implanted cardiac resynchronization therapy defibrillator (CRT-D).

Authors:  C Brockmann; T Sommer; R Pirzer; H U Kerl; I S Nolte; A Förster; M A Brockmann
Journal:  Clin Neuroradiol       Date:  2012-10-19       Impact factor: 3.649

5.  Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.

Authors:  Saman Nazarian; Rozann Hansford; Amir A Rahsepar; Valeria Weltin; Diana McVeigh; Esra Gucuk Ipek; Alan Kwan; Ronald D Berger; Hugh Calkins; Albert C Lardo; Michael A Kraut; Ihab R Kamel; Stefan L Zimmerman; Henry R Halperin
Journal:  N Engl J Med       Date:  2017-12-28       Impact factor: 91.245

6.  Rationale and Design of the CONCERT-HF Trial (Combination of Mesenchymal and c-kit+ Cardiac Stem Cells As Regenerative Therapy for Heart Failure).

Authors:  Roberto Bolli; Joshua M Hare; Keith L March; Carl J Pepine; James T Willerson; Emerson C Perin; Phillip C Yang; Timothy D Henry; Jay H Traverse; Raul D Mitrani; Aisha Khan; Ivonne Hernandez-Schulman; Doris A Taylor; Darcy L DiFede; João A C Lima; Atul Chugh; John Loughran; Rachel W Vojvodic; Shelly L Sayre; Judy Bettencourt; Michelle Cohen; Lem Moyé; Ray F Ebert; Robert D Simari
Journal:  Circ Res       Date:  2018-04-27       Impact factor: 17.367

7.  Rationale and Design of the SENECA (StEm cell iNjECtion in cAncer survivors) Trial.

Authors:  Roberto Bolli; Joshua M Hare; Timothy D Henry; Carrie G Lenneman; Keith L March; Kathy Miller; Carl J Pepine; Emerson C Perin; Jay H Traverse; James T Willerson; Phillip C Yang; Adrian P Gee; João A Lima; Lem Moyé; Rachel W Vojvodic; Shelly L Sayre; Judy Bettencourt; Michelle Cohen; Ray F Ebert; Robert D Simari
Journal:  Am Heart J       Date:  2018-04-04       Impact factor: 4.749

8.  Comparison of allogeneic vs autologous bone marrow–derived mesenchymal stem cells delivered by transendocardial injection in patients with ischemic cardiomyopathy: the POSEIDON randomized trial.

Authors:  Joshua M Hare; Joel E Fishman; Gary Gerstenblith; Darcy L DiFede Velazquez; Juan P Zambrano; Viky Y Suncion; Melissa Tracy; Eduard Ghersin; Peter V Johnston; Jeffrey A Brinker; Elayne Breton; Janice Davis-Sproul; Ivonne H Schulman; John Byrnes; Adam M Mendizabal; Maureen H Lowery; Didier Rouy; Peter Altman; Cheryl Wong Po Foo; Phillip Ruiz; Alexandra Amador; Jose Da Silva; Ian K McNiece; Alan W Heldman; Richard George; Albert Lardo
Journal:  JAMA       Date:  2012-12-12       Impact factor: 56.272

Review 9.  Importance Of Delayed Enhanced Cardiac MRI In Idiopathic RVOT-VT: Differentiating Mimics Including Early Stage ARVC And Cardiac Sarcoidosis.

Authors:  Carlos Macias; Keijiro Nakamura; Roderick Tung; Noel G Boyle; Shivkumar Kalyanam; Jason S Bradfield
Journal:  J Atr Fibrillation       Date:  2014-12-31

Review 10.  MRI in patients with pacemakers: overview and procedural management.

Authors:  Henning Bovenschulte; Klaus Schlüter-Brust; Thomas Liebig; Erland Erdmann; Peer Eysel; Carsten Zobel
Journal:  Dtsch Arztebl Int       Date:  2012-04-13       Impact factor: 5.594

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.