Literature DB >> 22379308

Evaluation of dimensional stability of autoclavable elastomeric impression material.

G P Surendra1, Ayesha Anjum, C L Satish Babu, Shilpa Shetty.   

Abstract

Impressions are important sources of cross contamination between patients and dental laboratories. As a part of infection control impressions contaminated with variety of micro-organisms via blood and oral secretions should be cleaned and disinfected or sterilized before being handled in dental laboratory. The purpose of this study was to determine the effect of autoclaving on dimensional stability of elastomeric impression material (polyvinyl siloxane-Affinis). In this in vitro study standardized stainless steel die as per ADA specification number 19 was fabricated. Polyvinyl siloxane (Affinis) light body and putty viscosity elastomeric impression materials were used. A total of 40 impressions of the stainless steel die were made and numeric coding system was used to identify the samples. Measurements were made using a measuring microscope. Distance between the cross lines CD and C'D' reproduced in the impression were measured before autoclaving, immediately after autoclaving and 24 hours after autoclaving and dimensional change was calculated. The data obtained was subjected to statistical analysis. The mean difference in dimensional change between the three groups was not statistically significant (P > 0.05). However the results revealed that there was higher mean dimensional change immediately after autoclaving when compared to the other 2 time intervals. It is desirable to delay the casting of an autoclavable elastomeric impression material by about 24 hours. Though disinfection of impression is routinely followed autoclaving of impression is an effective method of sterilization.

Entities:  

Keywords:  Autoclavable; Dimensionalstability; Elastomeric impression material

Year:  2011        PMID: 22379308      PMCID: PMC3095735          DOI: 10.1007/s13191-011-0061-1

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  5 in total

1.  Effect of disinfectant agents on dimensional stability of elastomeric impression materials.

Authors:  G L Adabo; E Zanarotti; R G Fonseca; C A Cruz
Journal:  J Prosthet Dent       Date:  1999-05       Impact factor: 3.426

2.  Dimensional stability of seven elastomeric impression materials immersed in disinfectants.

Authors:  A Thouati; E Deveaux; A Iost; P Behin
Journal:  J Prosthet Dent       Date:  1996-07       Impact factor: 3.426

3.  Effects of chemical disinfectant solutions on the stability and accuracy of the dental impression complex.

Authors:  M P Rios; S M Morgano; R S Stein; L Rose
Journal:  J Prosthet Dent       Date:  1996-10       Impact factor: 3.426

4.  Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.

Authors:  G H Johnson; K D Chellis; G E Gordon; X Lepe
Journal:  J Prosthet Dent       Date:  1998-04       Impact factor: 3.426

5.  Surface quality and long-term dimensional stability of current elastomeric impression materials after disinfection.

Authors:  Mary P Walker; Meagan Rondeau; Cynthia Petrie; Amy Tasca; Karen Williams
Journal:  J Prosthodont       Date:  2007-06-09       Impact factor: 2.752

  5 in total
  5 in total

1.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

2.  Evaluation of setting time, tear strength, dimensional stability and antimicrobial property of silver and titanium nanoparticles incorporated elastomeric impression material.

Authors:  Kapoor Abhijeet; J Brintha Jei; K Murugesan; B Muthukumar
Journal:  J Oral Biol Craniofac Res       Date:  2022-07-19

3.  Effect of Chemical Disinfection on Surface Detail Reproduction and Dimensional Stability of a New Vinyl Polyether Silicone Elastomeric Impression Material.

Authors:  Monika Khatri; Sneha S Mantri; Suryakant C Deogade; Abhilasha Bhasin; Shivkumar Mantri; Neetu Khatri; Priyanka Jain; Deepak Chauhan
Journal:  Contemp Clin Dent       Date:  2020-07-13

4.  Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study.

Authors:  Swati Joshi Asopa; U Narendra Padiyar; Sumit Verma; Prerna Suri; Nagaveni S Somayaji; Indu Cherangapadath Radhakrishnan
Journal:  J Family Med Prim Care       Date:  2020-03-26

5.  Comparing the Accuracy of Three Different Impression Materials in Making Duplicate Dies.

Authors:  Farshad Bajoghli; Mahmoud Sabouhi; Saeid Nosouhian; Amin Davoudi; Zeynab Behnamnia
Journal:  J Int Oral Health       Date:  2015-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.