Literature DB >> 17559536

Surface quality and long-term dimensional stability of current elastomeric impression materials after disinfection.

Mary P Walker1, Meagan Rondeau, Cynthia Petrie, Amy Tasca, Karen Williams.   

Abstract

PURPOSE: The objectives of this investigation were to evaluate the effect of disinfection on surface quality and dimensional stability of more recent, reformulated vinylpolysiloxane (VPS) and polyether (PE) materials.
METHODS: Using ANSI/American Dental Association (ADA) specification 19 protocols, 50 impressions of stainless steel dies were made with each material. Ten impressions of each material were randomly assigned to a treatment group: (1) no disinfectant; (2) 10-minute dual phenol immersion; (3) 1-hour dual phenol; (4) 10-minute sodium hypochlorite (NaOCl); and (5) 1-hour NaOCl. Impression surface quality immediately after disinfection was categorized as smooth/shiny, matte, or wrinkled/sticky. Dimensional stability was evaluated by measuring dimensional accuracy according to specification 19 after 24-hour, 1-week, and 2-week storage at ambient laboratory conditions.
RESULTS: The PE material surface quality was significantly affected (Pearson Chi-square, p<or= 0.05) by NaOCl with a mottled surface on 30% of the impressions after 10-minute immersion and a matte/sticky surface on 100% of the PE impressions after 1-hour immersion. Separate 2-factor analyses of variance (ANOVA) and Bonferroni post hoc tests of dimensional accuracy within each material indicated a significant difference (p<or= 0.05) between non-disinfected and disinfected PE impressions, which exhibited expansion. There were also significant differences (p<or= 0.05) in both VPS and PE dimensional accuracy as a function of measurement time related to increasing shrinkage over time in non-disinfected and disinfected impressions.
CONCLUSIONS: Despite PE expansion following disinfection and continued shrinkage of both the non-disinfected and disinfected VPS and PE impressions over a 2-week period, all dimensional accuracy measurements met the ADA standard, <or=0.5% dimensional change. Based on this evidence, neither NaOCl nor dual phenol disinfectants used for varying time periods adversely affected the dimensional stability of the more recent formulations of VPS and PE; however, Impregum PentaSoft PE surface quality appeared to be adversely affected by increasing exposure to NaOCl.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17559536     DOI: 10.1111/j.1532-849X.2007.00206.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  15 in total

1.  Evaluation of dimensional stability of autoclavable elastomeric impression material.

Authors:  G P Surendra; Ayesha Anjum; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2011-04-19

2.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

3.  Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection.

Authors:  Nikolas Poulis; Anthony Prombonas; Stavros Yannikakis; Thanasis Karampotsos; Martha-Spyridoula Katsarou; Nikolaos Drakoulis
Journal:  J Clin Diagn Res       Date:  2016-12-01

4.  Comparison of the dimensional and morphological accuracy of three-dimensional digital dental casts digitized using different methods.

Authors:  Jiahui Ye; Shimin Wang; Zixuan Wang; Yunsong Liu; Yuchun Sun; Hongqiang Ye; Yongsheng Zhou
Journal:  Odontology       Date:  2022-09-07       Impact factor: 2.885

5.  Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

Authors:  Suresh S Kamble; Rakshit Vijay Khandeparker; P Somasundaram; Shweta Raghav; Rashmi P Babaji; T Joju Varghese
Journal:  J Int Oral Health       Date:  2015-09

6.  An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization.

Authors:  Poonam K Khinnavar; B H Dhanya Kumar; D B Nandeeshwar
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

7.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

8.  Wettability changes in polyether impression materials subjected to immersion disinfection.

Authors:  Shweta Shetty; Giridhar Kamat; Rajesh Shetty
Journal:  Dent Res J (Isfahan)       Date:  2013-07

9.  Effect of mixing techniques on bacterial attachment and disinfection time of polyether impression material.

Authors:  Umut Guler; Yasemin Budak; Emrah Ruh; Yesim Ocal; Senay Canay; Yakut Akyon
Journal:  Eur J Dent       Date:  2013-09

10.  Dimensional stability of two impression materials after a 6-month storage period.

Authors:  Francisco Martins; Patrícia Branco; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.