Literature DB >> 8814627

Dimensional stability of seven elastomeric impression materials immersed in disinfectants.

A Thouati1, E Deveaux, A Iost, P Behin.   

Abstract

Dental impressions can increase the transmission of microorganisms and infections. The purpose of this study was to assess the influence of three disinfectant solutions on the dimensional accuracy of seven elastomeric impression materials. Impressions of a test block were either left untreated (controls) or treated by immersion in a disinfectant solution. Measurements were taken on die stone replicas of the impressions. Comparisons were made between (1) the measurements for the variations in the nontreated impressions and those for the treated impressions and (2) measurements for the treated impressions and the test block. Results indicated that the aminoamphoteric agent or glutaraldehyde derivative-based solutions created little change in relation to the initial dimensional accuracy of the impression products. However, the sodium hypochlorite solution often leads to expansion by comparison with controls. By comparison to the test block, this expansion then makes it possible in most cases to obtain better dimensional accuracy than initially. Within the limits of this study this expansion could lead to an improvement in clinical fixed prosthodontic procedures.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8814627     DOI: 10.1016/s0022-3913(96)90338-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  Evaluation of dimensional stability of autoclavable elastomeric impression material.

Authors:  G P Surendra; Ayesha Anjum; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2011-04-19

2.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

3.  Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection.

Authors:  Nikolas Poulis; Anthony Prombonas; Stavros Yannikakis; Thanasis Karampotsos; Martha-Spyridoula Katsarou; Nikolaos Drakoulis
Journal:  J Clin Diagn Res       Date:  2016-12-01

4.  The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts.

Authors:  Wala M Amin; Muna H Al-Ali; Sandra K Al Tarawneh; Sahar Th Taha; Mohamed W Saleh; Nadia Ereifij
Journal:  J Clin Med Res       Date:  2009-06-21

5.  An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization.

Authors:  Poonam K Khinnavar; B H Dhanya Kumar; D B Nandeeshwar
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

6.  The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials.

Authors:  Usama Nassar; Carlos Flores-Mir; Giseon Heo; Ysidora Torrealba
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

7.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

8.  A comparative evaluation of disinfection effect of exposures to ultra-violet light and direct current glow discharge on Candida Albicans colonies coated over elastomeric impression material: An in vitro study.

Authors:  Vijay Anand
Journal:  J Pharm Bioallied Sci       Date:  2013-06

9.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

10.  Dimensional stability of two impression materials after a 6-month storage period.

Authors:  Francisco Martins; Patrícia Branco; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14
View more