Literature DB >> 8897290

Effects of chemical disinfectant solutions on the stability and accuracy of the dental impression complex.

M P Rios1, S M Morgano, R S Stein, L Rose.   

Abstract

Currently available impression materials were not designed for disinfection or sterilization, and it is conceivable that disinfectants may adversely affect impressions. This study evaluated the accuracy and dimensional stability of polyether (Permadyne/Impregum) and polyvinyl siloxane (Express) impression materials retained by their adhesives in two different acrylic resin tray designs (perforated and nonperforated) when the materials were immersed for either 30 or 60 minutes in three high-level disinfectants. Distilled water and no solution served as controls. A stainless steel test analog similar to ADA specification No. 19 was used. A total of 400 impressions were made with all combinations of impression materials, tray designs, disinfectant, and soaking times. Samples were evaluated microscopically before and after immersion and 48 hours after soaking. Results indicated that these two impression materials were dimensionally stable. Because the results emphasized the stability and accuracy of the impression complex under various conditions, dentists can perform disinfection procedures similar to the protocol of this study without concern for clinically significant distortion of the impression.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8897290     DOI: 10.1016/s0022-3913(96)90538-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

1.  Evaluation of dimensional stability of autoclavable elastomeric impression material.

Authors:  G P Surendra; Ayesha Anjum; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2011-04-19

2.  A comparative study between microwave irradiation and sodium hypochlorite chemical disinfection: a prosthodontic view.

Authors:  Kashish Goel; Rupesh Gupta; Jitender Solanki; Meghanand Nayak
Journal:  J Clin Diagn Res       Date:  2014-04-15

3.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

4.  Effect of Chemical Disinfection on Surface Detail Reproduction and Dimensional Stability of a New Vinyl Polyether Silicone Elastomeric Impression Material.

Authors:  Monika Khatri; Sneha S Mantri; Suryakant C Deogade; Abhilasha Bhasin; Shivkumar Mantri; Neetu Khatri; Priyanka Jain; Deepak Chauhan
Journal:  Contemp Clin Dent       Date:  2020-07-13

5.  The Effect of Disinfectants and a Surface Wetting Agent on the Wettability of Elastomeric Impression Materials: An In Vitro Study.

Authors:  Pritam P Lad; Minal Gurjar; Sachin Gunda; Vivek Gurjar; Nandan K Rao
Journal:  J Int Oral Health       Date:  2015-06

6.  The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials.

Authors:  Usama Nassar; Carlos Flores-Mir; Giseon Heo; Ysidora Torrealba
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

7.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

8.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

9.  Dimensional stability of two impression materials after a 6-month storage period.

Authors:  Francisco Martins; Patrícia Branco; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14

10.  Comparative Evaluation of the Effect of Chemical Disinfectants and Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Siloxane Impressions.

Authors:  Sharayu Vinod Nimonkar; Vikram M Belkhode; S R Godbole; Pranali Vinod Nimonkar; Trupti Dahane; Seema Sathe
Journal:  J Int Soc Prev Community Dent       Date:  2019-04-12
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.