Literature DB >> 9576321

Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.

G H Johnson1, K D Chellis, G E Gordon, X Lepe.   

Abstract

STATEMENT OF PROBLEM: Because irreversible hydrocolloid impressions imbibe blood and saliva, immersion rather than spray disinfection may be more effective. Polyether has been shown to be dimensionally sensitive to immersion disinfection.
PURPOSE: The aim of this study was to determine whether irreversible hydrocolloid and polyether impressions could be disinfected by immersion without sacrificing accuracy and surface quality.
MATERIAL AND METHODS: Impressions were made of a master mandibular arch containing a crown preparation. Changes between the master and working casts were assessed. Irreversible hydrocolloids (Jeltrate; Palgaflex), a polyether (Impregum F), and an addition silicone (President) were used. Disinfectants were an iodophor (Biocide), a glyoxal glutaraldehyde (Impresept de), and a phenol glutaraldehyde (Sporicidin). The control was without disinfection. Casts were formed in Type IV gypsum. The roughness of working dies was also recorded and an analysis of variance was used for statistical evaluation. Results. Casts from disinfected irreversible hydrocolloid and elastomeric impressions maintained accuracy for anteroposterior and cross arch dimensions where differences from the master was less than 0.1%. Buccolingual and mesiodistal dimensions of working dies (disinfected and control) were 6 to 8 microm larger than the master for addition silicones and 11 to 16 pm for polyethers. The occlusogingival dimension of dies for control and disinfected polyether was 9 pm longer than the master compared with -3 microm for addition silicone. The range of mean surface roughness of working dies made from irreversible hydrocolloids was 1.4 to 1.7 microm and ranged from 0.5 to 0.7 microm for elastomeric impressions. Conclusion. Immersion disinfection of Jeltrate material with iodophor and Palgaflex material with glyoxal glutaraldehyde produced casts and dies as accurate as the control. Control and disinfected elastomeric impression produced dies as clinically accurate and smooth as the master. Disinfection of irreversible hydrocolloid impressions with the glyoxal and phenol glutaraldehyde produced a surface smoother than controls.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9576321     DOI: 10.1016/s0022-3913(98)70160-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  21 in total

1.  Evaluation of dimensional stability of autoclavable elastomeric impression material.

Authors:  G P Surendra; Ayesha Anjum; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2011-04-19

2.  Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study.

Authors:  Himanshu Aeran; Sakshi Sharma; Varun Kumar; Neelu Gupta
Journal:  J Clin Diagn Res       Date:  2015-08-01

3.  Dimensional changes of alginate dental impression materials.

Authors:  N Nallamuthu; M Braden; M P Patel
Journal:  J Mater Sci Mater Med       Date:  2006-12       Impact factor: 3.896

4.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

5.  In vivo Study of the Accuracy of Dual-arch Impressions.

Authors:  Luciana Martinelli Santayana de Lima; Gilberto Antonio Borges; Luiz Henrique Burnett Junior; Ana Maria Spohr
Journal:  J Int Oral Health       Date:  2014-06-26

6.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

7.  Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection.

Authors:  Nikolas Poulis; Anthony Prombonas; Stavros Yannikakis; Thanasis Karampotsos; Martha-Spyridoula Katsarou; Nikolaos Drakoulis
Journal:  J Clin Diagn Res       Date:  2016-12-01

8.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

9.  Wettability changes in polyether impression materials subjected to immersion disinfection.

Authors:  Shweta Shetty; Giridhar Kamat; Rajesh Shetty
Journal:  Dent Res J (Isfahan)       Date:  2013-07

10.  Evaluation of properties of irreversible hydrocolloid impression materials mixed with disinfectant liquids.

Authors:  Arul Amalan; Kishore Ginjupalli; Nagaraja Upadhya
Journal:  Dent Res J (Isfahan)       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.