Literature DB >> 22327929

Advances in nuclear cardiac instrumentation with a view towards reduced radiation exposure.

Piotr J Slomka1, Damini Dey, W Lane Duvall, Milena J Henzlova, Daniel S Berman, Guido Germano.   

Abstract

Recent advances in nuclear cardiology instrumentation have enabled myocardial perfusion imaging (MPI) with improved image quality and faster scan times. These developments also can be exploited to reduce the effective radiation dose to the patient. In this review, we discuss these technologies including new single photon emission computed tomography (SPECT) and positron emission tomography (PET) scanners, as well as novel reconstruction software with regard to their potential for the reduction of the patient radiation dose. New advances in nuclear cardiology instrumentation will allow routine rest/stress MPI imaging with low radiation doses (<5 mSv) and fast imaging times, even by the software-only solutions. It is possible to further reduce the MPI radiation dose to less than 2 to 3 mSv range with standard acquisition times. PET perfusion imaging also can be performed with very low doses especially by the three-dimensional scanners allowing hybrid PET/computed tomographic angiography (CTA) imaging with low overall dose. In addition, stress-only protocols can be utilized to further reduce the radiation dose and the overall test time.

Entities:  

Mesh:

Year:  2012        PMID: 22327929      PMCID: PMC3677860          DOI: 10.1007/s11886-012-0248-z

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  54 in total

1.  Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease.

Authors:  Hidetaka Nishina; Piotr J Slomka; Aiden Abidov; Shunichi Yoda; Cigdem Akincioglu; Xingping Kang; Ishac Cohen; Sean W Hayes; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2006-01       Impact factor: 10.057

2.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

3.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

4.  Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography.

Authors:  Michael Fiechter; Jelena R Ghadri; Silke M Kuest; Aju P Pazhenkottil; Mathias Wolfrum; Rene N Nkoulou; Robert Goetti; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-07-15       Impact factor: 9.236

5.  Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique.

Authors:  Bernhard A Herzog; Ronny R Buechel; Lars Husmann; Aju P Pazhenkottil; Irene A Burger; Mathias Wolfrum; Rene N Nkoulou; Ines Valenta; Jelena R Ghadri; Valerie Treyer; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2010-09-16       Impact factor: 10.057

6.  Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography.

Authors:  Ryo Nakazato; Balaji K Tamarappoo; Xingping Kang; Arik Wolak; Faith Kite; Sean W Hayes; Louise E J Thomson; John D Friedman; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Med       Date:  2010-10-18       Impact factor: 10.057

Review 7.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

8.  New Imaging Protocols for New Single Photon Emission CT Technologies.

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  Curr Cardiovasc Imaging Rep       Date:  2010-04-20

9.  Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT.

Authors:  Fabio P Esteves; Jonathan A Nye; Akbar Khan; Russell D Folks; Raghuveer K Halkar; Ernest V Garcia; David M Schuster; Stamatios Lerakis; Paolo Raggi; John R Votaw
Journal:  J Nucl Cardiol       Date:  2009-11-24       Impact factor: 5.952

10.  Normal stress-only versus standard stress/rest myocardial perfusion imaging: similar patient mortality with reduced radiation exposure.

Authors:  Su Min Chang; Faisal Nabi; Jiaqiong Xu; Umara Raza; John J Mahmarian
Journal:  J Am Coll Cardiol       Date:  2009-11-13       Impact factor: 24.094

View more
  28 in total

1.  Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom study.

Authors:  Orazio Zoccarato; Camilla Scabbio; Elena De Ponti; Roberta Matheoud; Lucia Leva; Sabrina Morzenti; Marco Menzaghi; Riccardo Campini; Claudio Marcassa; Angelo Del Sole; Silvana Garancini; Cinzia Crivellaro; Marco Brambilla; Michela Lecchi
Journal:  J Nucl Cardiol       Date:  2013-11-23       Impact factor: 5.952

Review 2.  Cardiac hybrid imaging.

Authors:  Oliver Gaemperli; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05       Impact factor: 9.236

3.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients.

Authors:  M Lecchi; I Martinelli; O Zoccarato; C Maioli; Giovanni Lucignani; A Del Sole
Journal:  J Nucl Cardiol       Date:  2016-02-24       Impact factor: 5.952

4.  Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study.

Authors:  Andrew J Einstein; Ron Blankstein; Howard Andrews; Mathews Fish; Richard Padgett; Sean W Hayes; John D Friedman; Mehreen Qureshi; Harivony Rakotoarivelo; Piotr Slomka; Ryo Nakazato; Sabahat Bokhari; Marcello Di Carli; Daniel S Berman
Journal:  J Nucl Med       Date:  2014-06-30       Impact factor: 10.057

5.  Nuclear cardiology as it should look in the twenty-first century.

Authors:  W Lane Duvall; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2015-05-14       Impact factor: 5.952

Review 6.  Nuclear imaging of the breast: translating achievements in instrumentation into clinical use.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

7.  The prognosis of a normal Tl-201 stress-only SPECT MPI study.

Authors:  W Lane Duvall; Robert J Hiensch; Elliot J Levine; Lori B Croft; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2012-07-20       Impact factor: 5.952

Review 8.  Stress-only SPECT myocardial perfusion imaging: a review.

Authors:  B M Pampana Gowd; Gary V Heller; Matthew W Parker
Journal:  J Nucl Cardiol       Date:  2014-07-09       Impact factor: 5.952

9.  Absolute myocardial blood flow quantification with SPECT/CT: is it possible?

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2014-12       Impact factor: 5.952

Review 10.  CFR and FFR assessment with PET and CTA: strengths and limitations.

Authors:  Ryo Nakazato; Ran Heo; Jonathon Leipsic; James K Min
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.