Literature DB >> 24272971

Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom study.

Orazio Zoccarato1, Camilla Scabbio, Elena De Ponti, Roberta Matheoud, Lucia Leva, Sabrina Morzenti, Marco Menzaghi, Riccardo Campini, Claudio Marcassa, Angelo Del Sole, Silvana Garancini, Cinzia Crivellaro, Marco Brambilla, Michela Lecchi.   

Abstract

BACKGROUND: This investigation used image data generated by a physical phantom over a wide range of count statistics to evaluate the effectiveness of several of the newer commercially available SPECT reconstruction iterative algorithms (IRR) in improving perfusion defect contrast and spatial resolution, while controlling image noise.
METHODS: A cardiac phantom was imaged using four different gamma cameras over a wide range of counts statistics (from 6 to 0.8 Mcounts). Images were reconstructed with FBP, OSEM, and the IRR available on site. IRR were applied without corrections (IRR NC), with attenuation correction (IRR AC), scatter correction (IRR SC), and attenuation + scatter corrections (IRR SCAC). Four image performance indices related to spatial resolution, contrast, and image noise were analyzed.
RESULTS: IRR NC always determined significant improvements in all indices in comparison to FBP or OSEM. Improvements were emphasized with IRR SC and IRR SCAC. Count reduction from 6 to 1.5 Mcounts did not impair the performances of any of the considered indices.
CONCLUSIONS: This is the first study comparing the relative performance of different, commercially available, IRR software, over a wide range of count statistics; the additional effect of scatter and attenuation corrections, alone or in combination, was also evaluated. Our results confirm that IRR algorithms produce substantial benefits with respect to conventional FBP or OSEM reconstruction methods, as assessed through different figures of merit, in particular when SC and/or SCAC are also included.

Entities:  

Mesh:

Year:  2013        PMID: 24272971     DOI: 10.1007/s12350-013-9821-0

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  15 in total

1.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

2.  A qualitative and quantitative assessment of the impact of three processing algorithms with halving of study count statistics in myocardial perfusion imaging: filtered backprojection, maximal likelihood expectation maximisation and ordered subset expectation maximisation with resolution recovery.

Authors:  B N Modi; J L E Brown; G Kumar; R M Driver; A D Kelion; A M Peters; J C Fowler
Journal:  J Nucl Cardiol       Date:  2012-06-30       Impact factor: 5.952

3.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

4.  Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores.

Authors:  R Glenn Wells; Karen Soueidan; Rachel Timmins; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2013-06-05       Impact factor: 5.952

5.  A multi-center phantom study comparing image resolution from three state-of-the-art SPECT-CT systems.

Authors:  Tyler Hughes; Sergey Shcherbinin; Anna Celler
Journal:  J Nucl Cardiol       Date:  2009-08-06       Impact factor: 5.952

6.  Wide beam reconstruction for half-dose or half-time cardiac gated SPECT acquisitions: optimization of resources and reduction in radiation exposure.

Authors:  Claudio Marcassa; Riccardo Campini; Orazio Zoccarato; Paolo Calza
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-11-11       Impact factor: 9.236

Review 7.  Advances in nuclear cardiac instrumentation with a view towards reduced radiation exposure.

Authors:  Piotr J Slomka; Damini Dey; W Lane Duvall; Milena J Henzlova; Daniel S Berman; Guido Germano
Journal:  Curr Cardiol Rep       Date:  2012-04       Impact factor: 2.931

8.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

9.  Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Linda Thompson; Yossi Srour
Journal:  J Nucl Cardiol       Date:  2009-06-17       Impact factor: 5.952

10.  Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging.

Authors:  Lotte H Enevoldsen; Changez A K Menashi; Ulrik B Andersen; Lars T Jensen; Otto M Henriksen
Journal:  J Nucl Cardiol       Date:  2013-08-21       Impact factor: 5.952

View more
  17 in total

1.  Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18F-FDG cardiac PET: A multi-center phantom study.

Authors:  Roberta Matheoud; Michela Lecchi; Domenico Lizio; Camilla Scabbio; Claudio Marcassa; Lucia Leva; Angelo Del Sole; Carlo Rodella; Luca Indovina; Christian Bracco; Marco Brambilla; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-01-12       Impact factor: 5.952

2.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients.

Authors:  M Lecchi; I Martinelli; O Zoccarato; C Maioli; Giovanni Lucignani; A Del Sole
Journal:  J Nucl Cardiol       Date:  2016-02-24       Impact factor: 5.952

3.  Comparative analysis of cadmium-zincum-telluride cameras dedicated to myocardial perfusion SPECT: A phantom study.

Authors:  Orazio Zoccarato; Domenico Lizio; Annarita Savi; Luca Indovina; Camilla Scabbio; Lucia Leva; Angelo Del Sole; Claudio Marcassa; Roberta Matheoud; Michela Lecchi; Marco Brambilla
Journal:  J Nucl Cardiol       Date:  2015-07-02       Impact factor: 5.952

4.  Image quality characteristics of myocardial perfusion SPECT imaging using state-of-the-art commercial software algorithms: evaluation of 10 reconstruction methods.

Authors:  Taher Hosny; Magdy M Khalil; Abdo A Elfiky; Wael M Elshemey
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-12-15

5.  The long way to dose reduction in myocardial perfusion imaging.

Authors:  Michela Lecchi; Angelo Del Sole
Journal:  J Nucl Cardiol       Date:  2017-06-30       Impact factor: 5.952

6.  The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: a phantom study.

Authors:  Federico Caobelli; Stefano Ren Kaiser; James Thomas Thackeray; Frank Michael Bengel; Matteo Chieregato; Alberto Soffientini; Claudio Pizzocaro; Giordano Savelli; Ugo Paolo Guerra; Marco Galelli; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2014-10-02       Impact factor: 5.952

7.  Differences in polar-map patterns using the novel technologies for myocardial perfusion imaging.

Authors:  Orazio Zoccarato; Claudio Marcassa; Domenico Lizio; Lucia Leva; Giovanni Lucignani; Annarita Savi; Camilla Scabbio; Roberta Matheoud; Michela Lecchi; Marco Brambilla
Journal:  J Nucl Cardiol       Date:  2016-05-27       Impact factor: 5.952

8.  Advances in image reconstruction software in nuclear cardiology: Is all that glitters gold?

Authors:  Claudio Marcassa; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-05-24       Impact factor: 5.952

9.  Impact of non-specific normal databases on perfusion quantification of low-dose myocardial SPECT studies.

Authors:  Camilla Scabbio; Orazio Zoccarato; Simona Malaspina; Giovanni Lucignani; Angelo Del Sole; Michela Lecchi
Journal:  J Nucl Cardiol       Date:  2017-10-17       Impact factor: 5.952

10.  Automatic evaluation of myocardial perfusion on SPECT: Need for "Normality".

Authors:  Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2017-10-25       Impact factor: 5.952

View more