Literature DB >> 20847159

Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique.

Bernhard A Herzog1, Ronny R Buechel, Lars Husmann, Aju P Pazhenkottil, Irene A Burger, Mathias Wolfrum, Rene N Nkoulou, Ines Valenta, Jelena R Ghadri, Valerie Treyer, Philipp A Kaufmann.   

Abstract

UNLABELLED: The aim of this study was to validate attenuation correction (AC) using low-dose standard CT for myocardial perfusion imaging (MPI) on a novel ultra fast γ-camera with cadmium-zinc-telluride (CZT) detector technology.
METHODS: Sixty-six patients (body mass index ± SD, 27.2 ± 3.5 kg/m(2); range, 19.1-36.0 kg/m(2)) underwent a 1-d (99m)Tc-tetrofosmin adenosine stress-rest imaging protocol with 15-min acquisitions on a standard dual-head SPECT camera. All scans were repeated within minutes on the CZT camera, with 3-min acquisitions for stress (low dose) and 2-min acquisitions for rest (high dose) as recently established. We compared maximum myocardial uptake (20-segment model) from CZT versus standard SPECT MPI by intraclass correlation without and with CT AC. In addition, clinical agreement for each coronary territory for all scans from both devices was assessed, and Bland-Altmann (BA) limits of agreement for percentage uptake were calculated.
RESULTS: The clinical agreement between CZT and standard SPECT cameras was 96% for noncorrected low- and high-dose images (r = 0.90 and BA = -18 to 15, and r = 0.91 and BA = -15 to 16, respectively), and agreement after AC was 96% for low- and 99% for high-dose images (r = 0.87 and BA = -16 to 14, and r = 0.88 and BA = -16 to 14, respectively).
CONCLUSION: Our results support that AC of MPI on the novel CZT camera, compared with AC MPI on a conventional SPECT camera, is feasible because it provides a high correlation of segmental tracer uptake and an excellent clinical agreement.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20847159     DOI: 10.2967/jnumed.110.078170

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  21 in total

1.  Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device.

Authors:  Michael Fiechter; Jelena R Ghadri; Mathias Wolfrum; Silke M Kuest; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Cathérine Gebhard; Tobias A Fuchs; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-12-06       Impact factor: 9.236

2.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

3.  [SPECT/CT - Technical aspects and optimization possibilities].

Authors:  W Römer
Journal:  Radiologe       Date:  2012-07       Impact factor: 0.635

4.  Extracardiac findings on computed tomography attenuation correction: Is it worth paying extra attention?

Authors:  Dominik C Benz; Tobias A Fuchs
Journal:  J Nucl Cardiol       Date:  2017-05-08       Impact factor: 5.952

5.  Diagnostic implications of CZT SPECT and impact of CT attenuation correction.

Authors:  Andrew Peters; Jeevan Kumar; Pravin V Patil
Journal:  J Nucl Cardiol       Date:  2017-06-23       Impact factor: 5.952

6.  Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging.

Authors:  Marvin Grossmann; Andreas A Giannopoulos; Fabiola A Bechtiger; Michael Messerli; Moritz Schwyzer; Dominik C Benz; Ken Kudura; Catherine Gebhard; Christoph Gräni; Aju P Pazhenkottil; Philipp A Kaufmann; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2018-06-19       Impact factor: 5.952

7.  Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose.

Authors:  Mohamed Mouden; Jorik R Timmer; Jan Paul Ottervanger; Stoffer Reiffers; Ad H J Oostdijk; Siert Knollema; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-03-17       Impact factor: 9.236

8.  Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera.

Authors:  Amir Pourmoghaddas; Karen Vanderwerf; Terrence D Ruddy; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2014-10-24       Impact factor: 5.952

9.  Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera.

Authors:  Cecilia Hindorf; Jenny Oddstig; Fredrik Hedeer; Magnus J Hansson; Jonas Jögi; Henrik Engblom
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

10.  3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera.

Authors:  John A Kennedy; Ora Israel; Alex Frenkel
Journal:  J Nucl Cardiol       Date:  2014-01-16       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.