Literature DB >> 20956478

Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography.

Ryo Nakazato1, Balaji K Tamarappoo, Xingping Kang, Arik Wolak, Faith Kite, Sean W Hayes, Louise E J Thomson, John D Friedman, Daniel S Berman, Piotr J Slomka.   

Abstract

UNLABELLED: A recently developed camera system for high-speed SPECT (HS-SPECT) myocardial perfusion imaging shows excellent correlation with conventional SPECT. Our goal was to test the diagnostic accuracy of an automated quantification of combined upright and supine myocardial SPECT for detection of coronary artery disease (CAD) (≥ 70% luminal diameter stenosis or, in left main coronary artery, ≥ 50% luminal diameter stenosis) in comparison to invasive coronary angiography (ICA).
METHODS: We studied 142 patients undergoing upright and supine HS-SPECT, including 56 consecutive patients (63% men; mean age ± SD, 64 ± 13 y; 45% exercise stress) without known CAD who underwent diagnostic ICA within 6 mo of HS-SPECT and 86 consecutive patients with a low likelihood of CAD. Reference limits for upright and supine HS-SPECT were created from studies of patients with a low likelihood of CAD. Automated software adopted from supine-prone analysis was used to quantify the severity and extent of perfusion abnormality and was expressed as total perfusion deficit (TPD). TPD was obtained for upright (U-TPD), supine (S-TPD), and combined upright-supine acquisitions (C-TPD). Stress U-TPD ≥ 5%, S-TPD ≥ 5%, and C-TPD ≥ 3% myocardium were considered abnormal for per-patient analysis, and U-TPD, S-TPD, and C-TPD ≥ 2% in each coronary artery territory were considered abnormal for per-vessel analysis.
RESULTS: On a per-patient basis, the sensitivity was 91%, 88%, and 94% for U-TPD, S-TPD, and C-TPD, respectively, and specificity was 59%, 73%, and 86% for U-TPD, S-TPD, and C-TPD, respectively. C-TPD had a larger area under the receiver-operating-characteristic curve than U-TPD or S-TPD for identification of stenosis ≥ 70% (0.94 vs. 0.88 and 0.89, P < 0.05 and not significant, respectively). On a per-vessel basis, the sensitivity was 67%, 66%, and 69% for U-TPD, S-TPD, and C-TPD, respectively, and specificity was 91%, 94%, and 97% for U-TPD, S-TPD, and C-TPD, respectively (P = 0.02 for specificity U-TPD vs. C-TPD).
CONCLUSION: In this first comparison of HS-SPECT with ICA, new automated quantification of combined upright and supine HS-SPECT shows high diagnostic accuracy for detecting clinically significant CAD, with findings comparable to those reported using conventional SPECT.

Entities:  

Mesh:

Year:  2010        PMID: 20956478      PMCID: PMC3130607          DOI: 10.2967/jnumed.110.078782

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  17 in total

1.  Quantification of serial changes in myocardial perfusion.

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  J Nucl Med       Date:  2004-12       Impact factor: 10.057

2.  Automated quantification of myocardial perfusion SPECT using simplified normal limits.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Cigdem Akincioglu; Aiden Abidov; John D Friedman; Sean W Hayes; Guido Germano
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease.

Authors:  Hidetaka Nishina; Piotr J Slomka; Aiden Abidov; Shunichi Yoda; Cigdem Akincioglu; Xingping Kang; Ishac Cohen; Sean W Hayes; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2006-01       Impact factor: 10.057

4.  Underestimation of extent of ischemia by gated SPECT myocardial perfusion imaging in patients with left main coronary artery disease.

Authors:  Daniel S Berman; Xingping Kang; Piotr J Slomka; James Gerlach; Ling de Yang; Sean W Hayes; John D Friedman; Louise E J Thomson; Guido Germano
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

5.  Recent technologic advances in nuclear cardiology.

Authors:  James A Patton; Piotr J Slomka; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

6.  Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men. Impact of diabetes mellitus on incremental prognostic value and effect on patient management.

Authors:  Daniel S Berman; Xingping Kang; Sean W Hayes; John D Friedman; Ishac Cohen; Aiden Abidov; Leslee J Shaw; Aman M Amanullah; Guido Germano; Rory Hachamovitch
Journal:  J Am Coll Cardiol       Date:  2003-04-02       Impact factor: 24.094

7.  Combined quantitative analysis of attenuation corrected and non-corrected myocardial perfusion SPECT: Method development and clinical validation.

Authors:  Yuan Xu; Mathews Fish; James Gerlach; Mark Lemley; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2010-04-14       Impact factor: 5.952

8.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

9.  Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation.

Authors:  Daniel S Berman; Aiden Abidov; Xingping Kang; Sean W Hayes; John D Friedman; Maria G Sciammarella; Ishac Cohen; James Gerlach; Parker B Waechter; Guido Germano; Rory Hachamovitch
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

10.  Optimal medical therapy with or without percutaneous coronary intervention to reduce ischemic burden: results from the Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluation (COURAGE) trial nuclear substudy.

Authors:  Leslee J Shaw; Daniel S Berman; David J Maron; G B John Mancini; Sean W Hayes; Pamela M Hartigan; William S Weintraub; Robert A O'Rourke; Marcin Dada; John A Spertus; Bernard R Chaitman; John Friedman; Piotr Slomka; Gary V Heller; Guido Germano; Gilbert Gosselin; Peter Berger; William J Kostuk; Ronald G Schwartz; Merill Knudtson; Emir Veledar; Eric R Bates; Benjamin McCallister; Koon K Teo; William E Boden
Journal:  Circulation       Date:  2008-02-11       Impact factor: 29.690

View more
  60 in total

1.  Comparison of high efficiency CZT SPECT MPI to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Maya H Barghash; Nitin K Kulkarni; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-06-03       Impact factor: 5.952

2.  Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Eric Ginsberg; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-12-07       Impact factor: 5.952

Review 3.  Quantitative analysis of perfusion studies: strengths and pitfalls.

Authors:  Piotr Slomka; Yuan Xu; Daniel Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

4.  D-SPECT: New technology, old tricks.

Authors:  Yung Hsiang Kao; Nathan Better
Journal:  J Nucl Cardiol       Date:  2015-09-25       Impact factor: 5.952

Review 5.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

6.  Direct quantification of left ventricular motion and thickening changes using rest-stress myocardial perfusion SPECT.

Authors:  Shahryar Karimi-Ashtiani; Reza Arsanjani; Mathews Fish; Paul Kavanagh; Guido Germano; Daniel Berman; Piotr Slomka
Journal:  J Nucl Med       Date:  2012-08-07       Impact factor: 10.057

7.  Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: quantitative vs visual analysis.

Authors:  Fabio P Esteves; James R Galt; Russell D Folks; Liudmila Verdes; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2013-11-28       Impact factor: 5.952

8.  Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol.

Authors:  Ryo Nakazato; Daniel S Berman; Sean W Hayes; Mathews Fish; Richard Padgett; Yuan Xu; Mark Lemley; Rafael Baavour; Nathaniel Roth; Piotr J Slomka
Journal:  J Nucl Med       Date:  2013-01-15       Impact factor: 10.057

9.  Deep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT: A Multicenter Study.

Authors:  Julian Betancur; Frederic Commandeur; Mahsaw Motlagh; Tali Sharir; Andrew J Einstein; Sabahat Bokhari; Mathews B Fish; Terrence D Ruddy; Philipp Kaufmann; Albert J Sinusas; Edward J Miller; Timothy M Bateman; Sharmila Dorbala; Marcelo Di Carli; Guido Germano; Yuka Otaki; Balaji K Tamarappoo; Damini Dey; Daniel S Berman; Piotr J Slomka
Journal:  JACC Cardiovasc Imaging       Date:  2018-03-14

10.  Prognostic value of quantitative high-speed myocardial perfusion imaging.

Authors:  Ryo Nakazato; Daniel S Berman; Heidi Gransar; Mark Hyun; Romalisa Miranda-Peats; Faith C Kite; Sean W Hayes; Louise E J Thomson; John D Friedman; Alan Rozanski; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-10-12       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.