Literature DB >> 31846121

First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Xiaoxuan He1, M Arcan Ertürk1, Andrea Grant1, Xiaoping Wu1, Russell L Lagore1, Lance DelaBarre1, Yiğitcan Eryaman1, Gregor Adriany1, Eddie J Auerbach1, Pierre-François Van de Moortele1, Kâmil Uğurbil1, Gregory J Metzger1.   

Abstract

PURPOSE: To investigate the feasibility of imaging the human torso and to evaluate the performance of several radiofrequency (RF) management strategies at 10.5T.
METHODS: Healthy volunteers were imaged on a 10.5T whole-body scanner in multiple target anatomies, including the prostate, hip, kidney, liver, and heart. Phase-only shimming and spoke pulses were used to demonstrate their performance in managing the B 1 + inhomogeneity present at 447 MHz. Imaging protocols included both qualitative and quantitative acquisitions to show the feasibility of imaging with different contrasts.
RESULTS: High-quality images were acquired and demonstrated excellent overall contrast and signal-to-noise ratio. The experimental results matched well with predictions and suggested good translational capabilities of the RF management strategies previously developed at 7T. Phase-only shimming provided increased efficiency, but showed pronounced limitations in homogeneity, demonstrating the need for the increased degrees of freedom made possible through single- and multispoke RF pulse design.
CONCLUSION: The first in-vivo human imaging was successfully performed at 10.5T using previously developed RF management strategies. Further improvement in RF coils, transmit chain, and full integration of parallel transmit functionality are needed to fully realize the benefits of 10.5T.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  10.5T; body imaging; magnetic resonance imaging; parallel transmit; ultra-high field imaging

Mesh:

Year:  2019        PMID: 31846121      PMCID: PMC7083701          DOI: 10.1002/mrm.28131

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  72 in total

1.  Local SAR reduction in parallel excitation based on channel-dependent Tikhonov parameters.

Authors:  Martijn Anton Cloos; Michel Luong; Guillaume Ferrand; Alexis Amadon; Denis Le Bihan; Nicolas Boulant
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

Review 2.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

3.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

4.  MR venography of the human brain using susceptibility weighted imaging at very high field strength.

Authors:  Peter J Koopmans; Rashindra Manniesing; Wiro J Niessen; Max A Viergever; Markus Barth
Journal:  MAGMA       Date:  2008-01-11       Impact factor: 2.310

5.  Modular 32-channel transceiver coil array for cardiac MRI at 7.0T.

Authors:  Andreas Graessl; Wolfgang Renz; Fabian Hezel; Matthias A Dieringer; Lukas Winter; Celal Oezerdem; Jan Rieger; Peter Kellman; Davide Santoro; Tomasz D Lindel; Tobias Frauenrath; Harald Pfeiffer; Thoralf Niendorf
Journal:  Magn Reson Med       Date:  2013-07-31       Impact factor: 4.668

6.  kT -points: short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume.

Authors:  M A Cloos; N Boulant; M Luong; G Ferrand; E Giacomini; D Le Bihan; A Amadon
Journal:  Magn Reson Med       Date:  2011-05-16       Impact factor: 4.668

7.  The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla.

Authors:  Alexander J E Raaijmakers; Michel Italiaander; Ingmar J Voogt; Peter R Luijten; Johannes M Hoogduin; Dennis W J Klomp; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

8.  Mitigating transmit B 1 inhomogeneity in the liver at 7T using multi-spoke parallel transmit RF pulse design.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Quant Imaging Med Surg       Date:  2014-02

9.  A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI.

Authors:  M Arcan Ertürk; Alexander J E Raaijmakers; Gregor Adriany; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-02-17       Impact factor: 4.668

10.  Multiparametric imaging with heterogeneous radiofrequency fields.

Authors:  Martijn A Cloos; Florian Knoll; Tiejun Zhao; Kai T Block; Mary Bruno; Graham C Wiggins; Daniel K Sodickson
Journal:  Nat Commun       Date:  2016-08-16       Impact factor: 14.919

View more
  20 in total

1.  Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10.5 tesla.

Authors:  Myung Kyun Woo; Lance DelaBarre; Byeong-Yeul Lee; Matt Waks; Russell Luke Lagore; Jerahmie Radder; Yigitcan Eryaman; Kamil Ugurbil; Gregor Adriany
Journal:  IEEE Access       Date:  2020-11-06       Impact factor: 3.367

2.  10.5 T MRI static field effects on human cognitive, vestibular, and physiological function.

Authors:  Andrea Grant; Gregory J Metzger; Pierre-François Van de Moortele; Gregor Adriany; Cheryl Olman; Lin Zhang; Joseph Koopermeiners; Yiğitcan Eryaman; Margaret Koeritzer; Meredith E Adams; Thomas R Henry; Kamil Uğurbil
Journal:  Magn Reson Imaging       Date:  2020-08-18       Impact factor: 2.546

3.  Going Low in a World Going High: The Physiologic Use of Lower Frequency Electron Paramagnetic Resonance.

Authors:  Howard J Halpern; Boris M Epel
Journal:  Appl Magn Reson       Date:  2020-10-18       Impact factor: 0.831

Review 4.  Progress in Imaging the Human Torso at the Ultrahigh Fields of 7 and 10.5 T.

Authors:  Kamil Uğurbil; Pierre-Francois Van de Moortele; Andrea Grant; Edward J Auerbach; Arcan Ertürk; Russell Lagore; Jutta M Ellermann; Xiaoxuan He; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-02       Impact factor: 2.266

5.  A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna.

Authors:  Alireza Sadeghi-Tarakameh; Steve Jungst; Mike Lanagan; Lance DelaBarre; Xiaoping Wu; Gregor Adriany; Gregory J Metzger; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2021-11-26       Impact factor: 4.668

6.  Long-term behavioral effects observed in mice chronically exposed to static ultra-high magnetic fields.

Authors:  Ivan Tkáč; Michael A Benneyworth; Tessa Nichols-Meade; Elizabeth L Steuer; Sarah N Larson; Gregory J Metzger; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2021-04-06       Impact factor: 4.668

7.  An 8-dipole transceive and 24-loop receive array for non-human primate head imaging at 10.5 T.

Authors:  Russell L Lagore; Steen Moeller; Jan Zimmermann; Lance DelaBarre; Jerahmie Radder; Andrea Grant; Kamil Ugurbil; Essa Yacoub; Noam Harel; Gregor Adriany
Journal:  NMR Biomed       Date:  2021-01-29       Impact factor: 4.044

Review 8.  New acquisition techniques and their prospects for the achievable resolution of fMRI.

Authors:  Saskia Bollmann; Markus Barth
Journal:  Prog Neurobiol       Date:  2020-10-23       Impact factor: 11.685

9.  Displacement current distribution on a high dielectric constant helmet and its effect on RF field at 10.5 T (447 MHz).

Authors:  Navid P Gandji; Christopher T Sica; Michael T Lanagan; Myung-Kyun Woo; Lance DelaBarre; Jerahmie Radder; Bei Zhang; Riccardo Lattanzi; Gregor Adriany; Kamil Ugurbil; Qing X Yang
Journal:  Magn Reson Med       Date:  2021-07-17       Impact factor: 3.737

10.  No need to detune transmitters in 32-channel receiver arrays at 7 T.

Authors:  Mark Gosselink; Hans Hoogduin; Martijn Froeling; Dennis W J Klomp
Journal:  NMR Biomed       Date:  2021-02-10       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.