Literature DB >> 22294428

Flip angle profile correction for T₁ and T₂ quantification with look-locker inversion recovery 2D steady-state free precession imaging.

Mitchell A Cooper1, Thanh D Nguyen, Pascal Spincemaille, Martin R Prince, Jonathan W Weinsaft, Yi Wang.   

Abstract

Fast methods using balanced steady-state free precession have been developed to reduce the scan time of T₁ and T₂ mapping. However, flip angle (FA) profiles created by the short radiofrequency pulses used in steady-state free precession deviate substantially from the ideal rectangular profile, causing T₁ and T₂ mapping errors. The purpose of this study was to develop a FA profile correction for T₁ and T₂ mapping with Look-Locker 2D inversion recovery steady-state free precession and to validate this method using 2D spin echo as a reference standard. Phantom studies showed consistent improvement in T₁ and T₂ accuracy using profile correction at multiple FAs. Over six human calves, profile correction provided muscle T₁ estimates with mean error ranging from excellent (-0.6%) at repetition time/FA = 18 ms/60° to acceptable (6.8%) at repetition time/FA = 4.9 ms/30°, while muscle T₂ estimates were less accurate with mean errors of 31.2% and 47.9%, respectively.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22294428      PMCID: PMC3342445          DOI: 10.1002/mrm.24151

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  On the transient phase of balanced SSFP sequences.

Authors:  Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

Review 2.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

3.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast.

Authors:  Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu
Journal:  AJR Am J Roentgenol       Date:  2004-08       Impact factor: 3.959

4.  T1 maps by K-space reduced snapshot-FLASH MRI.

Authors:  S Nekolla; T Gneiting; J Syha; R Deichmann; A Haase
Journal:  J Comput Assist Tomogr       Date:  1992 Mar-Apr       Impact factor: 1.826

5.  Cardiac fat navigator-gated steady-state free precession 3D magnetic resonance angiography of coronary arteries.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Single breath-hold T1 measurement using low flip angle TrueFISP.

Authors:  L Bokacheva; A J Huang; Q Chen; N Oesingmann; P Storey; H Rusinek; V S Lee
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

7.  Local flip angle correction for improved volume T1-quantification in three-dimensional dGEMRIC using the Look-Locker technique.

Authors:  Carl Siversson; Carl-Johan Tiderius; Leif Dahlberg; Jonas Svensson
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

8.  Repeatability of T1-quantification in dGEMRIC for three different acquisition techniques: two-dimensional inversion recovery, three-dimensional look locker, and three-dimensional variable flip angle.

Authors:  Carl Siversson; Carl-Johan Tiderius; Paul Neuman; Leif Dahlberg; Jonas Svensson
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

9.  A comparison of one-shot and recovery methods in T1 imaging.

Authors:  A P Crawley; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-05       Impact factor: 4.668

10.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold.

Authors:  Stefan K Piechnik; Vanessa M Ferreira; Erica Dall'Armellina; Lowri E Cochlin; Andreas Greiser; Stefan Neubauer; Matthew D Robson
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-19       Impact factor: 5.364

View more
  8 in total

1.  T1 mapping using saturation recovery single-shot acquisition at 3-tesla magnetic resonance imaging in hypertrophic cardiomyopathy: comparison to late gadolinium enhancement.

Authors:  Ryo Ogawa; Tomoyuki Kido; Masashi Nakamura; Teruhito Kido; Akira Kurata; Teruyoshi Uetani; Akiyoshi Ogimoto; Masao Miyagawa; Teruhito Mochizuki
Journal:  Jpn J Radiol       Date:  2017-01-19       Impact factor: 2.374

2.  Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm.

Authors:  Jiaxin Shao; Stanislas Rapacchi; Kim-Lien Nguyen; Peng Hu
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

3.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.

Authors:  Sébastien Roujol; Sebastian Weingärtner; Murilo Foppa; Kelvin Chow; Keigo Kawaji; Long H Ngo; Peter Kellman; Warren J Manning; Richard B Thompson; Reza Nezafat
Journal:  Radiology       Date:  2014-04-04       Impact factor: 11.105

4.  Fast in vivo quantification of T1 and T2 MRI relaxation times in the myocardium based on inversion recovery SSFP with in vitro validation post Gd-based contrast administration.

Authors:  Christof Karmonik; Adam Malaty; Malavosklish Bikram; Peter Schmitt; Sasan Partovi; Dipan J Shah
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

5.  Investigating and reducing the effects of confounding factors for robust T1 and T2 mapping with cardiac MR fingerprinting.

Authors:  Jesse I Hamilton; Yun Jiang; Dan Ma; Wei-Ching Lo; Vikas Gulani; Mark Griswold; Nicole Seiberlich
Journal:  Magn Reson Imaging       Date:  2018-06-30       Impact factor: 2.546

6.  Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI.

Authors:  Gustav J Strijkers; Ericky C A Araujo; Noura Azzabou; David Bendahan; Andrew Blamire; Jedrek Burakiewicz; Pierre G Carlier; Bruce Damon; Xeni Deligianni; Martijn Froeling; Arend Heerschap; Kieren G Hollingsworth; Melissa T Hooijmans; Dimitrios C Karampinos; George Loudos; Guillaume Madelin; Benjamin Marty; Armin M Nagel; Aart J Nederveen; Jules L Nelissen; Francesco Santini; Olivier Scheidegger; Fritz Schick; Christopher Sinclair; Ralph Sinkus; Paulo L de Sousa; Volker Straub; Glenn Walter; Hermien E Kan
Journal:  J Neuromuscul Dis       Date:  2019

7.  Quantification correction for free-breathing myocardial T mapping in mice using a recursively derived description of a T* relaxation pathway.

Authors:  Maximilian Gram; Daniel Gensler; Petra Albertova; Fabian Tobias Gutjahr; Kolja Lau; Paula-Anahi Arias-Loza; Peter Michael Jakob; Peter Nordbeck
Journal:  J Cardiovasc Magn Reson       Date:  2022-05-09       Impact factor: 6.903

8.  How accurate is MOLLI T1 mapping in vivo? Validation by spin echo methods.

Authors:  Mitchell A Cooper; Thanh D Nguyen; Pascal Spincemaille; Martin R Prince; Jonathan W Weinsaft; Yi Wang
Journal:  PLoS One       Date:  2014-09-11       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.