Literature DB >> 1545039

T1 maps by K-space reduced snapshot-FLASH MRI.

S Nekolla1, T Gneiting, J Syha, R Deichmann, A Haase.   

Abstract

The T1 maps evaluated from k-space reduced Snapshot fast low angle shot (FLASH) images provide high contrast parameter images for tissue characterization in vivo of any body region. An algorithm for computing T1 values that allows a fast and reliable evaluation of T1 maps and yields reproducible values of tissue parameters in MR imaging is presented. The algorithm combined with the Snapshot FLASH inversion recovery imaging sequence permits a precise determination of T1 values, even for T1 times as low as 50 ms. Comparison with a spectroscopical inversion recovery method on identical phantoms demonstrates the accuracy of this technique. With its total acquisition time of approximately 2 s, IR Snapshot FLASH is fast enough to be used in monitoring fast T1 dynamics.

Mesh:

Year:  1992        PMID: 1545039     DOI: 10.1097/00004728-199203000-00031

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  22 in total

Review 1.  Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements.

Authors:  Gunnar Brix; Jürgen Griebel; Fabian Kiessling; Frederik Wenz
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

2.  Assessment of Blood Hemodynamics by USPIO-Induced R(1) Changes in MRI of Murine Colon Carcinoma.

Authors:  Giulio Gambarota; H W M van Laarhoven; M Philippens; W J M Peeters; P Rijken; A van der Kogel; C J A Punt; A Heerschap
Journal:  Appl Magn Reson       Date:  2010-03-28       Impact factor: 0.831

3.  Nonrigid active shape model-based registration framework for motion correction of cardiac T1 mapping.

Authors:  Hossam El-Rewaidy; Maryam Nezafat; Jihye Jang; Shiro Nakamori; Ahmed S Fahmy; Reza Nezafat
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

Review 4.  Advanced imaging techniques for chronic pancreatitis.

Authors:  Anushri Parakh; Temel Tirkes
Journal:  Abdom Radiol (NY)       Date:  2020-05

5.  An open-source software tool for the generation of relaxation time maps in magnetic resonance imaging.

Authors:  Daniel R Messroghli; Andre Rudolph; Hassan Abdel-Aty; Ralf Wassmuth; Titus Kühne; Rainer Dietz; Jeanette Schulz-Menger
Journal:  BMC Med Imaging       Date:  2010-07-30       Impact factor: 1.930

6.  Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

Authors:  Hui Xue; Andreas Greiser; Sven Zuehlsdorff; Marie-Pierre Jolly; Jens Guehring; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2012-06-26       Impact factor: 4.668

7.  Myocardial perfusion imaging using a non-contrast agent MR imaging technique.

Authors:  C Waller; K H Hiller; S Voll; A Haase; G Ertl; W R Bauer
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

8.  T1 mapping, T2 mapping and MR elastography of the liver for detection and staging of liver fibrosis.

Authors:  David H Hoffman; Abimbola Ayoola; Dominik Nickel; Fei Han; Hersh Chandarana; Krishna Prasad Shanbhogue
Journal:  Abdom Radiol (NY)       Date:  2020-03

9.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

10.  Comparison of spoiled gradient echo and steady-state free-precession imaging for native myocardial T1 mapping using the slice-interleaved T1 mapping (STONE) sequence.

Authors:  Jihye Jang; Steven Bellm; Sébastien Roujol; Tamer A Basha; Maryam Nezafat; Shingo Kato; Sebastian Weingärtner; Reza Nezafat
Journal:  NMR Biomed       Date:  2016-10       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.