Literature DB >> 16767743

Cardiac fat navigator-gated steady-state free precession 3D magnetic resonance angiography of coronary arteries.

Thanh D Nguyen1, Pascal Spincemaille, Martin R Prince, Yi Wang.   

Abstract

Motion artifacts and the lack of accurate detection of cardiac motion present a major challenge for high-resolution cardiac MRI. Recently a multidimensional cardiac fat navigator was proposed to provide a fast and direct measurement of bulk cardiac motion. The objective of this study was to demonstrate the feasibility of employing the cardiac fat navigator in balanced steady-state free precession (SSFP) free-breathing 3D coronary MRA (CMRA). The cardiac fat navigator echo is optimized to provide both motion monitoring and epicardial fat suppression. Steady-state magnetization preparation, which is needed for SSFP CMRA, is optimized by comparing three preparation schemes: alpha/2, linear ramp with 20 RF pulses (20LR), and Kaiser ramp with six RF pulses (6KR). The present preliminary human study shows that the 6KR preparation provides better image quality than both the alpha/2 (P<0.0025) and the 20LR preparations (P<0.025) for free-breathing SSFP 3D CMRA (N=11). Copyright (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16767743     DOI: 10.1002/mrm.20938

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI.

Authors:  Mehdi H Moghari; Mehmet Akçakaya; Alan O'Connor; Tamer A Basha; Michele Casanova; Douglas Stanton; Lois Goepfert; Kraig V Kissinger; Beth Goddu; Michael L Chuang; Vahid Tarokh; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-06-10       Impact factor: 4.668

2.  Improved coronary MR angiography using wideband steady state free precession at 3 tesla with sub-millimeter resolution.

Authors:  Hsu-Lei Lee; Ajit Shankaranarayanan; Gerald M Pohost; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

Review 3.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

4.  Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.

Authors:  R Reeve Ingle; Holden H Wu; Nii Okai Addy; Joseph Y Cheng; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

5.  Flip angle profile correction for T₁ and T₂ quantification with look-locker inversion recovery 2D steady-state free precession imaging.

Authors:  Mitchell A Cooper; Thanh D Nguyen; Pascal Spincemaille; Martin R Prince; Jonathan W Weinsaft; Yi Wang
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

6.  Nonrigid Motion Correction With 3D Image-Based Navigators for Coronary MR Angiography.

Authors:  Jieying Luo; Nii Okai Addy; R Reeve Ingle; Corey A Baron; Joseph Y Cheng; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

7.  Free-breathing 3D steady-state free precession coronary magnetic resonance angiography: comparison of diaphragm and cardiac fat navigators.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

8.  In vivo quantification of femoral-popliteal compression during isometric thigh contraction: Assessment using MR angiography.

Authors:  Ryan Brown; Thanh D Nguyen; Pascal Spincemaille; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

9.  Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM).

Authors:  Jianing Pang; Himanshu Bhat; Behzad Sharif; Zhaoyang Fan; Louise E J Thomson; Troy LaBounty; John D Friedman; James Min; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-02-07       Impact factor: 4.668

10.  Effective motion-sensitizing magnetization preparation for black blood magnetic resonance imaging of the heart.

Authors:  Thanh D Nguyen; Ludovic de Rochefort; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2008-11       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.