Literature DB >> 22213531

Slice-by-slice B1+ shimming at 7 T.

Andrew T Curtis1, Kyle M Gilbert, L Martyn Klassen, Joseph S Gati, Ravi S Menon.   

Abstract

Parallel transmission has been used to reduce the inevitable inhomogeneous radiofrequency fields produced in human high-field MRI greater than 3 T. Further improvements in the transmit homogeneity and efficiency are possible by leveraging the additional degree of freedom permitted by multislice acquisitions. Compared to simple scaling of the flip angle to compensate for B1+ falloff along the radiofrequency coil, calculation of B1+ shim solutions on a slice-by-slice basis can markedly improve homogeneity and/or reduce transmitted power and global SAR. Performance measures were acquired at 7 T with a 15-channel head-only transceive array featuring elements distributed over all three logical axes, facilitating B1+ shimming over arbitrary orientations. Compared to a circularly polarized volume mode of the same coil, shimming to maximize excitation efficiency on a slice-by-slice basis yielded improvements in mean B1+ by 12.8±2.4% and a reduction in standard deviation of B1+ of 16.3±6.8%, while reducing relative SAR by 6.2±3.1%. When shimming for greater uniformity, the mean and standard deviation of B1+ were further improved by 15.9±2.6% and 26.2±10.4%, respectively, at the expense of a 135±8% increase in global SAR. Robust multislice-shim solutions are demonstrated that can be quickly calculated, applied in real time, and reliably improve on volume coil modes.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22213531     DOI: 10.1002/mrm.23319

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

2.  Tissue Border Enhancement by inversion recovery MRI at 7.0 Tesla.

Authors:  Mauro Costagli; Douglas A C Kelley; Mark R Symms; Laura Biagi; Riccardo Stara; Eleonora Maggioni; Gianluigi Tiberi; Carmen Barba; Renzo Guerrini; Mirco Cosottini; Michela Tosetti
Journal:  Neuroradiology       Date:  2014-04-25       Impact factor: 2.804

3.  Diffusion-weighted imaging of skull lesions.

Authors:  Daniel T Ginat; Rajiv Mangla; Gabrielle Yeaney; Sven Ekholm
Journal:  J Neurol Surg B Skull Base       Date:  2014-03-12

4.  A highly decoupled transmit-receive array design with triangular elements at 7T.

Authors:  Gang Chen; Bei Zhang; Martijn A Cloos; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2018-03-23       Impact factor: 4.668

Review 5.  Spinal cord MRI at 7T.

Authors:  Robert L Barry; S Johanna Vannesjo; Samantha By; John C Gore; Seth A Smith
Journal:  Neuroimage       Date:  2017-07-03       Impact factor: 6.556

6.  Simultaneous multislice excitation by parallel transmission.

Authors:  Benedikt A Poser; Robert James Anderson; Bastien Guérin; Kawin Setsompop; Weiran Deng; Azma Mareyam; Peter Serano; Lawrence L Wald; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-05-28       Impact factor: 4.668

7.  Hybrid-pair ratio adjustable power splitters for add-on RF shimming and array-compressed parallel transmission.

Authors:  Yue Zhu; Ming Lu; William A Grissom; John C Gore; Xinqiang Yan
Journal:  Magn Reson Med       Date:  2021-07-19       Impact factor: 4.668

8.  Eight-channel parallel transmit-receive system for 7 T MRI with optically controlled and monitored on-coil current-mode RF amplifiers.

Authors:  Natalia Gudino; Jacco A de Zwart; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2020-07-14       Impact factor: 3.737

9.  Increased glutamate levels observed upon functional activation in the anterior cingulate cortex using the Stroop Task and functional spectroscopy.

Authors:  Reggie Taylor; Betsy Schaefer; Maria Densmore; Richard W J Neufeld; Nagalingam Rajakumar; Peter C Williamson; Jean Théberge
Journal:  Neuroreport       Date:  2015-02-11       Impact factor: 1.837

10.  Volumetric imaging with homogenised excitation and static field at 9.4 T.

Authors:  Desmond H Y Tse; Christopher J Wiggins; Dimo Ivanov; Daniel Brenner; Jens Hoffmann; Christian Mirkes; Gunamony Shajan; Klaus Scheffler; Kâmil Uludağ; Benedikt A Poser
Journal:  MAGMA       Date:  2016-03-19       Impact factor: 2.310

View more