Literature DB >> 28684332

Spinal cord MRI at 7T.

Robert L Barry1, S Johanna Vannesjo2, Samantha By3, John C Gore4, Seth A Smith4.   

Abstract

Magnetic resonance imaging (MRI) of the human spinal cord at 7T has been demonstrated by a handful of research sites worldwide, and the spinal cord remains one of the areas in which higher fields and resolution could have high impact. The small diameter of the cord (∼1 cm) necessitates high spatial resolution to minimize partial volume effects between gray and white matter, and so MRI of the cord can greatly benefit from increased signal-to-noise ratio and contrasts at ultra-high field (UHF). Herein we review the current state of UHF spinal cord imaging. Technical challenges to successful UHF spinal cord MRI include radiofrequency (B1) nonuniformities and a general lack of optimized radiofrequency coils, amplified physiological noise, and an absence of methods for robust B0 shimming along the cord to mitigate image distortions and signal losses. Numerous solutions to address these challenges have been and are continuing to be explored, and include novel approaches for signal excitation and acquisition, dynamic shimming and specialized shim coils, and acquisitions with increased coverage or optimal slice angulations.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28684332      PMCID: PMC5894871          DOI: 10.1016/j.neuroimage.2017.07.003

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  103 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

Authors:  W M Teeuwisse; W M Brink; K N Haines; A G Webb
Journal:  Magn Reson Med       Date:  2012-01-27       Impact factor: 4.668

3.  Injury alters intrinsic functional connectivity within the primate spinal cord.

Authors:  Li Min Chen; Arabinda Mishra; Pai-Feng Yang; Feng Wang; John C Gore
Journal:  Proc Natl Acad Sci U S A       Date:  2015-04-22       Impact factor: 11.205

4.  7 Tesla 22-channel wrap-around coil array for cervical spinal cord and brainstem imaging.

Authors:  Bei Zhang; Alan C Seifert; Joo-Won Kim; Joseph Borrello; Junqian Xu
Journal:  Magn Reson Med       Date:  2016-11-17       Impact factor: 4.668

5.  Combined T2*-weighted measurements of the human brain and cervical spinal cord with a dynamic shim update.

Authors:  Jürgen Finsterbusch; Christian Sprenger; Christian Büchel
Journal:  Neuroimage       Date:  2013-04-17       Impact factor: 6.556

6.  Organization of the intrinsic functional network in the cervical spinal cord: A resting state functional MRI study.

Authors:  Xiaojia Liu; Fuqing Zhou; Xiang Li; Wenshu Qian; Jiaolong Cui; Iris Y Zhou; Keith D K Luk; Ed X Wu; Yong Hu
Journal:  Neuroscience       Date:  2016-08-31       Impact factor: 3.590

7.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

8.  Dynamic B0 shimming at 7 T.

Authors:  Saikat Sengupta; E Brian Welch; Yansong Zhao; David Foxall; Piotr Starewicz; Adam W Anderson; John C Gore; Malcolm J Avison
Journal:  Magn Reson Imaging       Date:  2011-03-12       Impact factor: 2.546

9.  Imaging of glutamate in the spinal cord using GluCEST.

Authors:  Feliks Kogan; Anup Singh; Catherine Debrosse; Mohammad Haris; Kejia Cai; Ravi Prakash Nanga; Mark Elliott; Hari Hariharan; Ravinder Reddy
Journal:  Neuroimage       Date:  2013-04-09       Impact factor: 6.556

10.  Intrinsic Resting-State Functional Connectivity in the Human Spinal Cord at 3.0 T.

Authors:  Oscar San Emeterio Nateras; Fang Yu; Eric R Muir; Carlos Bazan; Crystal G Franklin; Wei Li; Jinqi Li; Jack L Lancaster; Timothy Q Duong
Journal:  Radiology       Date:  2015-10-27       Impact factor: 11.105

View more
  17 in total

1.  Analysis of coil element distribution and dimension for matrix gradient coils.

Authors:  Hongyan He; Shufeng Wei; Huixian Wang; Wenhui Yang
Journal:  MAGMA       Date:  2022-06-11       Impact factor: 2.310

2.  Generic acquisition protocol for quantitative MRI of the spinal cord.

Authors:  Julien Cohen-Adad; Eva Alonso-Ortiz; Mihael Abramovic; Carina Arneitz; Nicole Atcheson; Laura Barlow; Robert L Barry; Markus Barth; Marco Battiston; Christian Büchel; Matthew Budde; Virginie Callot; Anna J E Combes; Benjamin De Leener; Maxime Descoteaux; Paulo Loureiro de Sousa; Marek Dostál; Julien Doyon; Adam Dvorak; Falk Eippert; Karla R Epperson; Kevin S Epperson; Patrick Freund; Jürgen Finsterbusch; Alexandru Foias; Michela Fratini; Issei Fukunaga; Claudia A M Gandini Wheeler-Kingshott; Giancarlo Germani; Guillaume Gilbert; Federico Giove; Charley Gros; Francesco Grussu; Akifumi Hagiwara; Pierre-Gilles Henry; Tomáš Horák; Masaaki Hori; James Joers; Kouhei Kamiya; Haleh Karbasforoushan; Miloš Keřkovský; Ali Khatibi; Joo-Won Kim; Nawal Kinany; Hagen Kitzler; Shannon Kolind; Yazhuo Kong; Petr Kudlička; Paul Kuntke; Nyoman D Kurniawan; Slawomir Kusmia; René Labounek; Maria Marcella Laganà; Cornelia Laule; Christine S Law; Christophe Lenglet; Tobias Leutritz; Yaou Liu; Sara Llufriu; Sean Mackey; Eloy Martinez-Heras; Loan Mattera; Igor Nestrasil; Kristin P O'Grady; Nico Papinutto; Daniel Papp; Deborah Pareto; Todd B Parrish; Anna Pichiecchio; Ferran Prados; Àlex Rovira; Marc J Ruitenberg; Rebecca S Samson; Giovanni Savini; Maryam Seif; Alan C Seifert; Alex K Smith; Seth A Smith; Zachary A Smith; Elisabeth Solana; Yuichi Suzuki; George Tackley; Alexandra Tinnermann; Jan Valošek; Dimitri Van De Ville; Marios C Yiannakas; Kenneth A Weber; Nikolaus Weiskopf; Richard G Wise; Patrik O Wyss; Junqian Xu
Journal:  Nat Protoc       Date:  2021-08-16       Impact factor: 17.021

3.  Multiple sclerosis lesions affect intrinsic functional connectivity of the spinal cord.

Authors:  Benjamin N Conrad; Robert L Barry; Baxter P Rogers; Satoshi Maki; Arabinda Mishra; Saakshi Thukral; Subramaniam Sriram; Aashim Bhatia; Siddharama Pawate; John C Gore; Seth A Smith
Journal:  Brain       Date:  2018-06-01       Impact factor: 13.501

4.  Multi-shot acquisitions for stimulus-evoked spinal cord BOLD fMRI.

Authors:  Robert L Barry; Benjamin N Conrad; Satoshi Maki; Jennifer M Watchmaker; Lydia J McKeithan; Bailey A Box; Quinn R Weinberg; Seth A Smith; John C Gore
Journal:  Magn Reson Med       Date:  2020-11-10       Impact factor: 4.668

5.  Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization.

Authors:  Xin Li; Jullie W Pan; Nikolai I Avdievich; Hoby P Hetherington; Joseph V Rispoli
Journal:  Magn Reson Med       Date:  2021-02-03       Impact factor: 3.737

6.  Multi-parametric quantitative in vivo spinal cord MRI with unified signal readout and image denoising.

Authors:  Francesco Grussu; Marco Battiston; Jelle Veraart; Torben Schneider; Julien Cohen-Adad; Timothy M Shepherd; Daniel C Alexander; Els Fieremans; Dmitry S Novikov; Claudia A M Gandini Wheeler-Kingshott
Journal:  Neuroimage       Date:  2020-04-29       Impact factor: 6.556

7.  A practical protocol for measurements of spinal cord functional connectivity.

Authors:  Robert L Barry; Benjamin N Conrad; Seth A Smith; John C Gore
Journal:  Sci Rep       Date:  2018-11-08       Impact factor: 4.379

8.  Intrinsic functional architecture of the non-human primate spinal cord derived from fMRI and electrophysiology.

Authors:  Tung-Lin Wu; Pai-Feng Yang; Feng Wang; Zhaoyue Shi; Arabinda Mishra; Ruiqi Wu; Li Min Chen; John C Gore
Journal:  Nat Commun       Date:  2019-03-29       Impact factor: 14.919

Review 9.  Traumatic and nontraumatic spinal cord injury: pathological insights from neuroimaging.

Authors:  Gergely David; Siawoosh Mohammadi; Allan R Martin; Julien Cohen-Adad; Nikolaus Weiskopf; Alan Thompson; Patrick Freund
Journal:  Nat Rev Neurol       Date:  2019-10-31       Impact factor: 42.937

Review 10.  Clinical 7 T MRI: Are we there yet? A review about magnetic resonance imaging at ultra-high field.

Authors:  Giuseppe Barisano; Farshid Sepehrband; Samantha Ma; Kay Jann; Ryan Cabeen; Danny J Wang; Arthur W Toga; Meng Law
Journal:  Br J Radiol       Date:  2018-11-01       Impact factor: 3.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.