Literature DB >> 22209963

Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens.

Bogna Stawarczyk1, Andreas Ender, Albert Trottmann, Mutlu Özcan, Jens Fischer, Christoph H F Hämmerle.   

Abstract

OBJECTIVE: This study tested the fracture load of milled and conventionally fabricated polymeric and glass-ceramic three-unit fixed dental prostheses (FDPs) after aging.
MATERIALS AND METHODS: FDPs were fabricated (N = 1,050) from four computer-aided design and computer-aided manufacturing (CAD/CAM) resins: (1) AT (artBlock Temp); (2) TC (Telio CAD); (3) ZP (ZENO PMMA); (4) CT (CAD-Temp); two conventionally fabricated resins, (5) IES (integral esthetic press), (6) CMK (CronMix K), and a glass-ceramic (control) (7) PG (IMAGINE PressX). Specimens of each group were tested immediately after fabrication (n = 15 per material). Seventy-five FDPs per material type were stored in artificial saliva (37°C) and 15 of them were randomly selected after aging (1, 7, 28, 90, and 180 days) for fracture load measurement. The remaining specimens (n = 60 per material) were subjected to chewing simulation (×120.000-1.200.000, 49 N, 5°C/50°C). The data were analyzed using two-way and one-way ANOVA followed by Scheffé test.
RESULTS: The interactions between FDP materials and aging time in both storage media showed a significant impact on the results (p < 0.001). Among saliva storage groups, TC and ZP showed the highest, and PG the lowest fracture load (p < 0.05). AT and CT were not affected from chewing simulation. TC, ZP, and AT presented the highest in ascending order (p < 0.05), PG and CMK showed the lowest fracture load after chewing simulation (p < 0.001).
CONCLUSIONS: Aging did not influence the fracture load of FDPs made of CAD/CAM resins. FDPs made of glass-ceramic showed significantly lower fracture load than those of all resin FDPs. CLINICAL RELEVANCE: Considering fracture load measurements, CAD/CAM resins tested could be alternative materials to glass-ceramic for FDP construction.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22209963     DOI: 10.1007/s00784-011-0670-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  27 in total

1.  Computer-aided designed/computer-assisted manufactured composite resin versus ceramic single-tooth restorations: a 3-year clinical study.

Authors:  Sara Vanoorbeek; Katleen Vandamme; Inge Lijnen; Ignace Naert
Journal:  Int J Prosthodont       Date:  2010 May-Jun       Impact factor: 1.681

2.  Influence of the processing technique on the flexural fatigue strength of denture base resins: an in vitro investigation.

Authors:  Rajlakshmi Banerjee; Sujoy Banerjee; P S Prabhudesai; S V Bhide
Journal:  Indian J Dent Res       Date:  2010 Jul-Sep

3.  A technique to improve the esthetic aspects of CAD/CAM composite resin restorations.

Authors:  Giovanni Tommaso Rocca; François Bonnafous; Nicolas Rizcalla; Ivo Krejci
Journal:  J Prosthet Dent       Date:  2010-10       Impact factor: 3.426

4.  Antagonist enamel wears more than ceramic inlays.

Authors:  N Krämer; K-H Kunzelmann; M Taschner; A Mehl; F Garcia-Godoy; R Frankenberger
Journal:  J Dent Res       Date:  2006-12       Impact factor: 6.116

5.  The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prostheses.

Authors:  Deyar Jallal Hadi Mahmood; Ewa H Linderoth; Per Vult Von Steyern
Journal:  Acta Odontol Scand       Date:  2011-01-13       Impact factor: 2.331

6.  Load-bearing capacity of handmade and computer-aided design--computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite.

Authors:  Emine Göncü Başaran; Emrah Ayna; Pekka K Vallittu; Lippo V J Lassila
Journal:  Acta Odontol Scand       Date:  2011-01-05       Impact factor: 2.331

7.  The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli.

Authors:  S S Scherrer; W G de Rijk
Journal:  Int J Prosthodont       Date:  1993 Sep-Oct       Impact factor: 1.681

8.  Adhesively luted, metal-free composite crowns after five years.

Authors:  Franziska Lehmann; Katrin Spiegl; Grit Eickemeyer; Peter Rammelsberg
Journal:  J Adhes Dent       Date:  2009-12       Impact factor: 2.359

9.  Approach for valuating the significance of laboratory simulation.

Authors:  Martin Rosentritt; Georgios Siavikis; Michael Behr; Carola Kolbeck; Gerhard Handel
Journal:  J Dent       Date:  2008-10-09       Impact factor: 4.379

10.  Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients.

Authors:  A Waltimo; M Könönen
Journal:  Acta Odontol Scand       Date:  1995-08       Impact factor: 2.331

View more
  21 in total

1.  Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

Authors:  Annette Wiegand; Lukas Stucki; Robin Hoffmann; Thomas Attin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-02-05       Impact factor: 3.573

2.  Bonding between CAD/CAM resin and resin composite cements dependent on bonding agents: three different in vitro test methods.

Authors:  Simona Gilbert; Christine Keul; Malgorzata Roos; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-05-24       Impact factor: 3.573

3.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

4.  Transmission of light in the visible spectrum (400-700 nm) and blue spectrum (360-540 nm) through CAD/CAM polymers.

Authors:  Jan-Frederik Güth; Ana Elisa Colle Kauling; Kazuhiko Ueda; Beuer Florian; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2016-02-26       Impact factor: 3.573

5.  Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study.

Authors:  Marcel Reymus; Rosalie Fabritius; Andreas Keßler; Reinhard Hickel; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2019-05-24       Impact factor: 3.573

6.  First clinical experiences with CAD/CAM-fabricated PMMA-based fixed dental prostheses as long-term temporaries.

Authors:  Fabian Huettig; Andreas Prutscher; Christoph Goldammer; Curt A Kreutzer; Heiner Weber
Journal:  Clin Oral Investig       Date:  2015-04-22       Impact factor: 3.573

7.  Effectiveness of surface treatment on bond strength of ceramic brackets to two types of CAD/CAM-prepared nanohybrid composites.

Authors:  Shaymaa Elsaka; Ali Hassan; Amr Elnaghy
Journal:  J Orofac Orthop       Date:  2022-02-21       Impact factor: 1.938

8.  The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments.

Authors:  Christine Keul; Daliah Kohen; Marlis Eichberger; Malgorzata Roos; Wolfgang Gernet; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2014-03-02       Impact factor: 3.573

9.  Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic.

Authors:  Bogna Stawarczyk; Andreas Krawczuk; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2014-06-15       Impact factor: 3.573

10.  Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses.

Authors:  Simon Taufall; Marlis Eichberger; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-03-15       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.