Literature DB >> 19339560

Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

Richard W McCalden1, Steven J MacDonald, Cecil H Rorabeck, Robert B Bourne, David G Chess, Kory D Charron.   

Abstract

BACKGROUND: Highly cross-linked polyethylene was introduced for clinical use in total hip arthroplasty with the expectation that it would exhibit less wear when compared with conventional polyethylene. The purpose of this study was to report the clinical and radiographic results, after a minimum of five years of follow-up, of a randomized, blinded, controlled trial comparing a conventional polyethylene with a first-generation highly cross-linked polyethylene.
METHODS: One hundred patients were enrolled in a prospective, randomized controlled study comparing highly cross-linked and conventional polyethylene acetabular liners in total hip arthroplasty. Fifty patients were in each group. At the time of follow-up, clinical outcomes were assessed and steady-state femoral head penetration rates (after bedding-in) for each patient were calculated with use of a validated radiographic technique. In addition, a statistical comparison of polyethylene wear between groups was performed with use of generalized estimating equations.
RESULTS: At a mean of 6.8 years postoperatively, there were no differences between the two polyethylene groups with regard to the Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), or Short Form-12 (SF-12) score. The mean femoral head penetration rate in the first through fifth years was found to be significantly lower in the group treated with the highly cross-linked polyethylene (0.003 mm/yr [95% confidence interval, +/-0.027]) than it was in the group treated with conventional polyethylene (0.051 mm/yr [95% confidence interval, +/-0.022]) (p=0.006). Men treated with a conventional polyethylene liner had a significantly higher (p<or=0.012) femoral head penetration rate (0.081 mm/yr [95% confidence interval, +/-0.065]) than both men and women with a highly cross-linked liner (-0.013 mm/yr [95% confidence interval, +/-0.074] and 0.009 mm/yr [95% confidence interval, +/-0.028], respectively). The general estimating equations demonstrated that the group with a highly cross-linked polyethylene liner had a significantly lower femoral head penetration rate than the group with a conventional polyethylene liner (p=0.025), and a significantly higher femoral head penetration rate was demonstrated in men with a conventional polyethylene liner when compared with both men and women with a highly cross-linked liner (p=0.003).
CONCLUSIONS: At a minimum of five years postoperatively, the steady-state femoral head penetration rate associated with this first-generation highly cross-linked polyethylene liner was significantly lower than that associated with a conventional polyethylene liner. Long-term follow-up is required to demonstrate the clinical benefit of this new material.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19339560     DOI: 10.2106/JBJS.H.00244

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  57 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

3.  Concomitant infection and local metal reaction in patients undergoing revision of metal on metal total hip arthroplasty.

Authors:  Kyle T Judd; Nicolas Noiseux
Journal:  Iowa Orthop J       Date:  2011

4.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

5.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

6.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

7.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

8.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

9.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

10.  Does increased diameter of metal femoral head associated with highly cross-linked polyethylene augment stress on the femoral stem and cortical hypertrophy?

Authors:  Seiya Ishii; Yasuhiro Homma; Tomonori Baba; Yuichi Shirogane; Kazuo Kaneko; Muneaki Ishijima
Journal:  Int Orthop       Date:  2021-02-22       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.