Literature DB >> 10884213

The effect of joint loading on acetabular wear measurement in total hip arthroplasty.

J M Martell1, S S Leopold, X Liu.   

Abstract

All radiographic calculations of acetabular wear assume concentric reduction of the prosthetic articulation. To date, no studies have shown that the femoral head is fully reduced on standard radiographs, and we have seen cases on early postoperative radiographs in which this assumption is not met. Using our computerized radiographic technique, 78 paired anteroposterior pelvic radiographs in 46 patients at a mean of 14 months after surgery (range, 1-92 months) were evaluated with and without joint loading. Displacement with loading was analyzed against time since surgery, a surrogate for acetabular wear. Regression analysis found a statistically significant increase in femoral head displacement after loading with longer duration of follow-up, but the rate of this increase was small (0.027 mm/y). This difference affects calculated wear values by <15%. We conclude that in a low-wear cohort, joint loading does not affect radiographic calculations of acetabular polyethylene wear in a clinically important way.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10884213     DOI: 10.1054/arth.2000.4336

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

2.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

3.  Evaluating the accuracy of wear formulae for acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2009-10-10       Impact factor: 2.602

4.  The linear penetration rate is not relevant for evaluating wear of dual mobility cups: an explant study.

Authors:  Bertrand Boyer; Thomas Neri; Alexandre Di Iorio; Jean Geringer; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2017-01-26       Impact factor: 3.075

5.  The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.

Authors:  Siôn Glyn-Jones; Geraint E R Thomas; Patrick Garfjeld-Roberts; Roger Gundle; Adrian Taylor; Peter McLardy-Smith; David W Murray
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

6.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

7.  Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.

Authors:  Kevin L Garvin; Curtis W Hartman; Jimmi Mangla; Nathan Murdoch; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2008-10-23       Impact factor: 4.176

8.  Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique.

Authors:  Eric Vandenbussche; Mohammed Saffarini; Ulrich Hansen; Fabienne Taillieu; Céline Mutschler; Bernard Augereau; Thomas M Gregory
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

9.  Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear.

Authors:  R John Looney; Allen Boyd; Saara Totterman; Gwy-Suk Seo; Jose Tamez-Pena; Debbie Campbell; Leonore Novotny; Christopher Olcott; John Martell; F Ann Hayes; Regis J O'Keefe; Edward M Schwarz
Journal:  Arthritis Res       Date:  2001-10-03