Literature DB >> 19969056

Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications.

Christian Offergeld1, Jan Kromeier, Saumil N Merchant, Nicoloz Lasurashvili, Marcus Neudert, Matthias Bornitz, Roland Laszig, Thomas Zahnert.   

Abstract

A large air-bone-gap after ossiculoplasty may be due to a malpositioned or displaced prosthesis. Rotational tomography (RT) has the potential to provide high-resolution images of implants without artifacts and with less radiation dosage than CT scan. Twenty-seven temporal bone specimens underwent measurements of middle ear transfer function using Laser-Doppler-Vibrometry (LDV) before and after placement of ossicular replacement prostheses (PORPs, TORPs) made of titanium. RT was performed on all specimens. RT allowed 3-dimensional viewing of the temporal bone, accurate localization of implants within the reconstructed middle ear and determination of angles between the inserted prostheses and the tympanic membrane (TM) and/or the malleus handle (MH). Presence or absence of contact between the implant and the TM, malleus or stapes could be clearly visualized. Displaced prostheses were readily identified. The functional LDV-measurements for TORPs showed a trend favoring coupling to the malleus handle, while for PORPs, coupling to the TM was favored. For PORPs, sound transmission was worse with increasing angles between the PORP and stapes superstructure (p<0.05). Following our experimental results RT is an innovative, relevant and useful imaging technique to obtain immediate postoperative feedback after ossicular reconstruction and to precisely determine the position of middle ear implants. Copyright (c) 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19969056      PMCID: PMC2866829          DOI: 10.1016/j.heares.2009.12.003

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  31 in total

1.  Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images.

Authors:  M D Seemann; O Seemann; H Bonél; M Suckfüll; K H Englmeier; A Naumann; C M Allen; M F Reiser
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

2.  Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear.

Authors:  David P Morris; Manohar Bance; Rene G van Wijhe; Michael Kiefte; Rachael Smith
Journal:  Laryngoscope       Date:  2004-02       Impact factor: 3.325

3.  Malleus handle fracture.

Authors:  Denis Ayache; Marc T Williams
Journal:  Otol Neurotol       Date:  2003-05       Impact factor: 2.311

4.  Ossicular reconstruction using hydroxyapatite prostheses with interposed cartilage.

Authors:  Taisuke Kobayashi; Kiyofumi Gyo; Takayuki Shinohara; Naoaki Yanagihara
Journal:  Am J Otolaryngol       Date:  2002 Jul-Aug       Impact factor: 1.808

5.  [Conventional tomographic investigations of the reconstructed middle ear in temporal bone specimen].

Authors:  C Offergeld; E Pilling; N Lazurashvili; T Beleites; J Kromeier; R Laszig; T Zahnert
Journal:  Laryngorhinootologie       Date:  2007-01-11       Impact factor: 1.057

6.  Virtual endoscopy of the tympanic cavity based on high-resolution multislice computed tomographic data.

Authors:  R Klingebiel; H C Bauknecht; O Kaschke; M Werbs; B Freigang; H Behrbohm; P Rogalla; R Lehmann
Journal:  Otol Neurotol       Date:  2001-11       Impact factor: 2.311

7.  Cartilage palisades in type III tympanoplasty: anatomic and functional long-term results.

Authors:  Manuel Bernal-Sprekelsen; Maria-Desamparados Romaguera Lliso; Juan-José Sanz Gonzalo
Journal:  Otol Neurotol       Date:  2003-01       Impact factor: 2.311

8.  Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography.

Authors:  Thomas Rodt; Sönke Bartling; Anja M Schmidt; Benno P Weber; Thomas Lenarz; Hartmut Becker
Journal:  Eur Radiol       Date:  2002-03-09       Impact factor: 5.315

9.  Pathology of the ossicular chain: comparison between virtual endoscopy and 2D spiral CT-data.

Authors:  Christian Martin; Frédéric Michel; Jean-François Pouget; Charlès Veyret; Pierre Bertholon; Jean-Michel Prades
Journal:  Otol Neurotol       Date:  2004-05       Impact factor: 2.311

10.  Imaging procedures in cochlear implant patients--evaluation of different radiological techniques.

Authors:  A Aschendorff; R Kubalek; A Hochmuth; A Bink; C Kurtz; P Lohnstein; T Klenzner; R Laszig
Journal:  Acta Otolaryngol Suppl       Date:  2004-05
View more
  11 in total

1.  Flat panel CT following stapes prosthesis insertion: an experimental and clinical study.

Authors:  K Zaoui; J Kromeier; M Neudert; C C Boedeker; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2011-12-08       Impact factor: 5.315

2.  [Intracochlear electrode position: evaluation after deep insertion using cone beam computed tomography].

Authors:  C Güldner; R Weiss; B Eivazi; S Bien; J A Werner; I Diogo
Journal:  HNO       Date:  2012-09       Impact factor: 1.284

3.  [Quality control following reconstructive middle ear surgery: from bench to bedside].

Authors:  C Offergeld
Journal:  HNO       Date:  2013-12       Impact factor: 1.284

4.  Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients.

Authors:  K Zaoui; J Kromeier; M Neudert; T Beleites; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

Review 5.  [Reconstruction of the middle ear with passive implants].

Authors:  T Zahnert
Journal:  HNO       Date:  2011-10       Impact factor: 1.284

6.  PORP vs. TORP: a meta-analysis.

Authors:  Huiqian Yu; Yingzi He; Yusu Ni; Yunfeng Wang; Na Lu; Huawei Li
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-02-12       Impact factor: 2.503

7.  Evaluation of functional results of CWD surgery with ossicular replacement prosthesis due to cholesteatoma using computed tomography.

Authors:  Selcuk Ucar; Mete Iseri; Murat Ozturk
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-10-06       Impact factor: 2.503

8.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

9.  Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study.

Authors:  Pieter Kemp; Jiska Van Stralen; Pim De Graaf; Erwin Berkhout; Pepijn Van Horssen; Paul Merkus
Journal:  J Int Adv Otol       Date:  2020-08       Impact factor: 1.017

10.  Visualisation of the Bonebridge by means of CT and CBCT.

Authors:  Christian Güldner; Julia Heinrichs; Rainer Weiß; Annette Paula Zimmermann; Benjamin Dassinger; Siegfried Bien; Jochen Alfred Werner; Isabell Diogo
Journal:  Eur J Med Res       Date:  2013-09-03       Impact factor: 2.175

View more