Literature DB >> 3347129

[Identification of middle ear implants in high-resolution computerized tomography].

G Oberascher1, M Grobovschek.   

Abstract

As a result of the increase in the use of computed tomography and the possibility of demonstrating very small structures, x-ray diagnosis is becoming more and more important in investigating complications after examined in patients as well as cadaver temporal bones by using high resolution middle ear computed tomography: 1. autologous/allogenic ossicular implants, 2. alloplastic implants made of ceramic, plastic or metal. As can be seen from our investigations the homografts and some of the implants are easily identifiable (autologous/allogenic ossicular implants, Ceravital and Frialit PORP/TORP and metal devices), are only partly identifiable (Fisch-Tef Platinum and Stainless Steel as well as Titan stapes pistons), hardly or not at all identifiable (PORP/TORP and stapes pistons made of plastic, e.g. teflon, silicone, plasti-pore). The same applies to ventilating tubes. Thus the position in the middle ear of metal tubes which have slipped can be seen clearly, whereas plastic tubes cannot be seen so well. It is of clinical importance that prosthesis dislocation is visible in CT so that should complications occur it is better possible to determine whether revision surgery is necessary. As, however, identification of various devices in CT is still not satisfactory, the manufactures must soon fulfil our demands for a contrast agent to be added to prosthesis.

Entities:  

Mesh:

Year:  1988        PMID: 3347129

Source DB:  PubMed          Journal:  Laryngol Rhinol Otol (Stuttg)        ISSN: 0340-1588


  4 in total

1.  Flat panel CT following stapes prosthesis insertion: an experimental and clinical study.

Authors:  K Zaoui; J Kromeier; M Neudert; C C Boedeker; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2011-12-08       Impact factor: 5.315

2.  Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses.

Authors:  Alessandro Bozzato; Tobias Struffert; Victoria Hertel; Heinrich Iro; Joachim Hornung
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

Review 3.  New trends in head and neck imaging.

Authors:  R Mösges
Journal:  Eur Arch Otorhinolaryngol       Date:  1993       Impact factor: 2.503

4.  [Rare complication after Le Fort I osteotomy].

Authors:  H Grundig; C Buitrago-Tellez; H-F Zeilhofer; M Podvinec
Journal:  HNO       Date:  2009-09       Impact factor: 1.284

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.