Literature DB >> 11704358

CT and MR imaging after middle ear surgery.

S Kösling1, F Bootz.   

Abstract

This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue.

Entities:  

Mesh:

Year:  2001        PMID: 11704358     DOI: 10.1016/s0720-048x(01)00379-5

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  15 in total

Review 1.  Imaging of the postoperative middle ear.

Authors:  Marc T Williams; Denis Ayache
Journal:  Eur Radiol       Date:  2004-01-29       Impact factor: 5.315

2.  Flat panel CT following stapes prosthesis insertion: an experimental and clinical study.

Authors:  K Zaoui; J Kromeier; M Neudert; C C Boedeker; T Zahnert; R Laszig; C Offergeld
Journal:  Eur Radiol       Date:  2011-12-08       Impact factor: 5.315

Review 3.  Neuroradiology of cholesteatomas.

Authors:  K Baráth; A M Huber; P Stämpfli; Z Varga; S Kollias
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-01       Impact factor: 3.825

Review 4.  Preoperative imaging assessment of chronic otitis media: what does the otologist need to know?

Authors:  A Stasolla; G Magliulo; A Cortese; A Roncacci; M Marini
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

5.  CT Findings in the External Auditory Canal after Transcanal Surgery.

Authors:  V Mingkwansook; H D Curtin; H R Kelly
Journal:  AJNR Am J Neuroradiol       Date:  2015-01-29       Impact factor: 3.825

6.  The diagnostic accuracy of non-echo-planar diffusion-weighted imaging in the detection of residual and/or recurrent cholesteatoma of the temporal bone.

Authors:  M H G Dremmen; P A M Hofman; J R Hof; R J Stokroos; A A Postma
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-22       Impact factor: 3.825

7.  Accuracy of turbo spin-echo diffusion-weighted imaging signal intensity measurements for the diagnosis of cholesteatoma.

Authors:  Burçe Özgen; Elif Bulut; Anıl Dolgun; Munir Demir Bajin; Levent Sennaroğlu
Journal:  Diagn Interv Radiol       Date:  2017 Jul-Aug       Impact factor: 2.630

8.  [Significance of computed tomography evaluation before revision stapes surgery].

Authors:  C Röösli; A Hoffmann; T Treumann; T E Linder
Journal:  HNO       Date:  2008-09       Impact factor: 1.284

9.  Comparison of echo-planar diffusion-weighted imaging and delayed postcontrast T1-weighted MR imaging for the detection of residual cholesteatoma.

Authors:  F Venail; A Bonafe; V Poirrier; M Mondain; A Uziel
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-16       Impact factor: 3.825

10.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.