| Literature DB >> 22110879 |
Jung-Yeon Yun1, So-Hee Park, Dae-Soon Cho, Hae-Jeung Jeung, Soon-Ae Lee, So Jin Seo.
Abstract
BACKGROUND: Unlike its use during stable conditions, central venous pressure (CVP) monitoring from a peripherally inserted central venous catheter (PICC) has not often been used in surgeries with significant hemodynamic alterations. The aim of this study was to evaluate the feasibility of measuring PICC pressure (PICCP) as an alternative to measuring centrally inserted central catheter pressure (CICCP) in adult liver transplantation (LT) patients.Entities:
Keywords: CVP; Liver transplantation; Peripherally inserted central catheter pressure
Year: 2011 PMID: 22110879 PMCID: PMC3219772 DOI: 10.4097/kjae.2011.61.4.281
Source DB: PubMed Journal: Korean J Anesthesiol ISSN: 2005-6419
Demographic and Clinical Characteristics of Patients
PICCP and CICCP during Liver Transplant Surgery
Values are expressed as means ± SD or ranges. CICCP: centrally inserted central catheter pressure, PICCP: peripherally inserted central catheter pressure, LT: liver transplantation, Bias: mean difference (PICCP-CICCP), P value: obtained from a mixed effects model for repeated measures analysis by accounting for within-subject variability, 95% CI (confidence interval): bias ± 1.96 × standard error (SE), Limit of agreement: bias ± 1.96 × standard deviation (SD).
Fig. 1Linear regression analysis plot of PICCP and CICCP for all data pairs with Pearson's correlation coefficient (r = 0.970, P < 0.001). CICCP: centrally inserted central catheter pressure, PICCP: peripherally inserted central catheter pressure.
Fig. 2Bland-Altman plot for all data pairs with calculation of bias and precision. The solid horizontal line represents the mean bias between the two devices. The two dashed horizontal lines represent the mean bias ± 1.96 times the standard deviation of the differences. CICCP: centrally inserted central catheter pressure, PICCP: peripherally inserted central catheter pressure.
Fig. 3Bland-Altman plot for each surgical period with calculation of bias and precision. (A) Bland-Altman plot for data points collected during preanhepatic period. (B) Bland-Altman plot for data points collected during anhepatic period. (C) Bland-Altman plot for data points collected during reperfusion period. (D) Bland-Altman plot for data points collected during neohepatic period. The solid horizontal line represents the mean bias between the two devices. The two dashed horizontal lines represent the mean bias ± 1.96 times the standard deviation of the differences. CICCP: centrally inserted central catheter pressure, PICCP: peripherally inserted central catheter pressure.