| Literature DB >> 16085686 |
Z Jankovic1, A Boon, R Prasad.
Abstract
Percutaneous bypass catheters are routinely used for veno-venous bypass (VVBP) during orthotopic liver transplantation (OLT). The recognized risks include bleeding, injury of vascular and nerve structures and lymphatic leakage. We describe a case where there were difficulties during catheterization and the patient suffered a cardiac arrest on commencing VVBP. Post-mortem examination revealed the bypass catheter tip in the pleural space and a large right haemothorax. Possible mechanisms of vascular perforation and preventative measures are discussed.Entities:
Mesh:
Year: 2005 PMID: 16085686 DOI: 10.1093/bja/aei216
Source DB: PubMed Journal: Br J Anaesth ISSN: 0007-0912 Impact factor: 9.166