Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

D J Macfarlane1, P Wong.   

Abstract

This study investigated the performance of the portable Cortex Metamax 3B (MM3B) automated gas analysis system during both simulated and human exercise using adolescents. Repeated measures using a Gas Exchange System Validator (GESV) across a range of simulated metabolic rates, showed the MM3B to be adequately reliable (both percentage errors, and percentage technical error of measurements <2%) for measuring expired ventilation (V (E)), oxygen consumption (VO(2)), and carbon dioxide production (VCO(2)). Over a 3 h period, the MM3B was shown to be acceptably stable in measuring gas fractions, as well as V (E), VO(2), and VCO(2) generated by the GESV, especially at moderate and high metabolic rates (drifts <2% and of minor physiological significance). Using eight healthy adolescents during rest, moderate, and vigorous cycle ergometry, the validity of the MM3B was tested against the primary criterion Douglas bag method (DBM) and a secondary criterion machine known to be accurate, the Jaeger Oxycon Pro system. No significant errors in V (E) were noted, yet the MM3B significantly overestimated both VO(2) and VCO(2) by approximately 10-17% at moderate and vigorous exercise as compared to the DBM and at all exercise levels compared to the Oxycon Pro. No significant differences were seen in any metabolic variable between the two criterion systems (DBM and Oxycon Pro). It is concluded the MM3B produces acceptably stable and reliable results, but is not adequately valid during moderate and vigorous exercise without some further correction of VO(2) and VCO(2).

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22075643      PMCID: PMC3371330          DOI: 10.1007/s00421-011-2230-7

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  14 in total

1.  Validation of the portable VmaxST system for oxygen-uptake measurement.

Authors:  M-A Brehm; J Harlaar; H Groepenhof
Journal:  Gait Posture       Date:  2004-08       Impact factor: 2.840

Review 2.  Validity and reliability of selected commercially available metabolic analyzer systems.

Authors:  L D Hodges; D A Brodie; P D Bromley
Journal:  Scand J Med Sci Sports       Date:  2005-10       Impact factor: 4.221

3.  Validity and stability of a computerized metabolic system with mixing chamber.

Authors:  Ø Foss; J Hallén
Journal:  Int J Sports Med       Date:  2005-09       Impact factor: 3.118

Review 4.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

5.  Validity of the VmaxST portable metabolic measurement system.

Authors:  C Matthew Laurent; Michael C Meyers; Clay A Robinson; Lorna R Strong; Charles Chase; Beelee Goodwin
Journal:  J Sports Sci       Date:  2008-05       Impact factor: 3.337

6.  Portable respiratory gas collection equipment.

Authors:  J Daniels
Journal:  J Appl Physiol       Date:  1971-07       Impact factor: 3.531

7.  A versatile system for measuring oxygen consumption in man.

Authors:  R E Johnson; F Robbins; R Schilke; P Molé; J Harris; D Wakat
Journal:  J Appl Physiol       Date:  1967-02       Impact factor: 3.531

8.  Automated VO2max calibrator for open-circuit indirect calorimetry systems.

Authors:  C J Gore; P G Catcheside; S N French; J M Bennett; J Laforgia
Journal:  Med Sci Sports Exerc       Date:  1997-08       Impact factor: 5.411

9.  Validity and reliability of the Cortex MetaMax3B portable metabolic system.

Authors:  Andrew J Vogler; Anthony J Rice; Christopher J Gore
Journal:  J Sports Sci       Date:  2010-05       Impact factor: 3.337

10.  Validation of the sensormedics (S2900Z) metabolic cart for pediatric exercise testing.

Authors:  V B Unnithan; J Wilson; D Buchanan; J A Timmons; J Y Paton
Journal:  Can J Appl Physiol       Date:  1994-12
View more
  32 in total

1.  Energy expenditure and muscle activity during lying, sitting, standing, and walking in people with motor-incomplete spinal cord injury.

Authors:  Bart Dekker; Olaf Verschuren; Astrid C J Balemans; Nadia Baart; Frank Tubbing; Casper F van Koppenhagen; Marcel W M Post
Journal:  Spinal Cord       Date:  2018-06-28       Impact factor: 2.772

2.  Proposal for a Specific Aerobic Test for Football Players: The "Footeval".

Authors:  Christophe Manouvrier; Johan Cassirame; Saïd Ahmaidi
Journal:  J Sports Sci Med       Date:  2016-12-01       Impact factor: 2.988

Review 3.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

4.  Predicting resting energy expenditure in people with chronic spinal cord injury.

Authors:  Yiming Ma; Sonja de Groot; Dirk Hoevenaars; Wendy Achterberg; Jacinthe Adriaansen; Peter J M Weijs; Thomas W J Janssen
Journal:  Spinal Cord       Date:  2022-07-02       Impact factor: 2.772

5.  Individual physiological responses to changes in shoe bending stiffness: a cluster analysis study on 96 runners.

Authors:  Mickael Chollet; Samuel Michelet; Nicolas Horvais; Sebastien Pavailler; Marlene Giandolini
Journal:  Eur J Appl Physiol       Date:  2022-10-13       Impact factor: 3.346

6.  The validity of the Moxus Modular metabolic system during incremental exercise tests: impacts on detection of small changes in oxygen consumption.

Authors:  Fernando G Beltrami; Christian Froyd; Asgeir Mamen; Timothy D Noakes
Journal:  Eur J Appl Physiol       Date:  2014-01-30       Impact factor: 3.078

7.  Effects of cycling workstation to get tertiary employee moving on their overall health: study protocol for a REMOVE trial.

Authors:  Terry Guirado; Lore Metz; Bruno Pereira; Audrey Bergouignan; David Thivel; Martine Duclos
Journal:  Trials       Date:  2021-05-22       Impact factor: 2.279

8.  Assessment of Peak Oxygen Uptake with a Smartwatch and its Usefulness for Training of Runners.

Authors:  Peter Düking; Bas Van Hooren; Billy Sperlich
Journal:  Int J Sports Med       Date:  2022-01-30       Impact factor: 2.997

9.  Estimating physical activity energy expenditure with the Kinect Sensor in an exergaming environment.

Authors:  David Nathan; Du Q Huynh; Jonas Rubenson; Michael Rosenberg
Journal:  PLoS One       Date:  2015-05-22       Impact factor: 3.240

10.  Inter-unit variability in two ParvoMedics TrueOne 2400 automated metabolic gas analysis systems.

Authors:  D J Macfarlane; H L Wu
Journal:  Eur J Appl Physiol       Date:  2012-09-04       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.