Literature DB >> 16181250

Validity and reliability of selected commercially available metabolic analyzer systems.

L D Hodges1, D A Brodie, P D Bromley.   

Abstract

Automated metabolic gas analysis systems have advanced considerably over the past decade. They provide an abundance of information, which is not possible by using the traditional Douglas bag method and have become an essential tool in both physiological monitoring and in the diagnosis of cardiopulmonary disease. The validity and reliability of the different online metabolic analyzer systems are not well known, with relatively few independent studies being published. The purpose of this review was to examine and evaluate current literature regarding the validity and reliability of commercially available metabolic analyzer systems. This review reveals significant differences between the available systems in the way that they capture and process basic respiratory measurements. Online metabolic analyzer systems were found to vary significantly when compared with Douglas bag methods. These variations have the potential to introduce error into the accuracy with which the health of cardiovascular system can be assessed or training loads can be assigned. Compounding this is the fact that many automated systems are a "black box", which makes it easy to generate data without the user having much understanding of how the data were generated. In conclusion automated metabolic analyser systems are a scientifically robust method for the evaluation of cardiopulmonary function. Individual researchers and clinicians must, however, be able to make their own decisions about the level of error that is tolerable for their individual needs. This presents a significant practical challenge in light of the speed with which technical developments in the field occur and we make some suggestions for the formulation of intersystem comparison studies.

Entities:  

Mesh:

Year:  2005        PMID: 16181250     DOI: 10.1111/j.1600-0838.2005.00477.x

Source DB:  PubMed          Journal:  Scand J Med Sci Sports        ISSN: 0905-7188            Impact factor:   4.221


  21 in total

1.  Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

Authors:  D J Macfarlane; P Wong
Journal:  Eur J Appl Physiol       Date:  2011-11-11       Impact factor: 3.078

Review 2.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

3.  Block training periodization in alpine skiing: effects of 11-day HIT on VO2max and performance.

Authors:  Fabio A Breil; Simone N Weber; Stefan Koller; Hans Hoppeler; Michael Vogt
Journal:  Eur J Appl Physiol       Date:  2010-04-04       Impact factor: 3.078

4.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

5.  Validity of the Oxycon Mobile metabolic system under field measuring conditions.

Authors:  Jane Salier Eriksson; Hans Rosdahl; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2011-05-11       Impact factor: 3.078

6.  The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Authors:  Hans Rosdahl; Thomas Lindberg; Fredrik Edin; Johnny Nilsson
Journal:  Eur J Appl Physiol       Date:  2012-12-07       Impact factor: 3.078

7.  Increased plasma levels of soluble vascular endothelial growth factor receptor 1 (sFlt-1) in women by moderate exercise and increased plasma levels of vascular endothelial growth factor in overweight/obese women.

Authors:  Kristina L Makey; Sharla G Patterson; James Robinson; Mark Loftin; Dwight E Waddell; Lucio Miele; Edmund Chinchar; Min Huang; Andrew D Smith; Mark Weber; Jian-Wei Gu
Journal:  Eur J Cancer Prev       Date:  2013-01       Impact factor: 2.497

8.  Lack of agreement between gas exchange variables measured by two metabolic systems.

Authors:  Djordje G Jakovljevic; David Nunan; Gay Donovan; Lynette D Hodges; Gavin R H Sandercock; David A Brodie
Journal:  J Sports Sci Med       Date:  2008-03-01       Impact factor: 2.988

Review 9.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

Review 10.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.