Automated VO2max calibrator for open-circuit indirect calorimetry systems.

C J Gore1, P G Catcheside, S N French, J M Bennett, J Laforgia.   

Abstract

The complete calibration of indirect calorimetry systems involves simultaneous checks of gas analyzers, volume device, and software, and this requires a machine that can mimic accurately and precisely the ventilation and expired gases of an athlete. While previous calibrators have been built successfully, none have matched the ventilatory flows produced by athletes during high intensity exercise. A calibrator able to simulate high aerobic power (VO2max calibrator) was fabricated and tested against conventional indirect calorimetry systems that use chain-compensated gasometers to measure expired volume (VE systems) and calibrated electronic gas analyzers. The calibrator was also checked against a system that measures inspired volume (VI system) with a turbine ventilometer. The pooled data from both VE and VI systems for predicted VO2 ranging from 2.9 to 7.9 L.min-1 and ventilation ranging from 89 to 246 L.min-1 how that the absolute accuracy (bias) of values measured by conventional indirect calorimetry systems compared with those predicted by the calibrator was excellent. The bias was < 35 mL.min-1 for VO2 and carbon dioxide production, < 0.50 L.min-1 for ventilator (VE BTPS), -0.02% absolute for the percentage of expired O2 and +0.02% absolute for the percentage of expired CO2. Overall, the precision of the measured VO2, VCO2, and VE BTPS was approximately 1%. This VO2max calibrator is a versatile device that can be used for routine calibration of most indirect calorimetry systems that assess the ventilation and aerobic power of athletes.

Entities:  

Mesh:

Year:  1997        PMID: 9268968     DOI: 10.1097/00005768-199708000-00016

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  10 in total

1.  Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

Authors:  D J Macfarlane; P Wong
Journal:  Eur J Appl Physiol       Date:  2011-11-11       Impact factor: 3.078

Review 2.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

3.  Performance and physiological responses during a sprint interval training session: relationships with muscle oxygenation and pulmonary oxygen uptake kinetics.

Authors:  Martin Buchheit; Chris R Abbiss; Jeremiah J Peiffer; Paul B Laursen
Journal:  Eur J Appl Physiol       Date:  2011-06-12       Impact factor: 3.078

Review 4.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

5.  Metabolic and mitogenic signal transduction in human skeletal muscle after intense cycling exercise.

Authors:  Mei Yu; Nigel K Stepto; Alexander V Chibalin; Lee G D Fryer; Dave Carling; Anna Krook; John A Hawley; Juleen R Zierath
Journal:  J Physiol       Date:  2003-01-15       Impact factor: 5.182

6.  Characteristics of Pedaling Muscle Stiffness among Cyclists of Different Performance Levels.

Authors:  Isaac López-Laval; Rafel Cirer-Sastre; Francisco Corbi; Sebastian Sitko
Journal:  Medicina (Kaunas)       Date:  2021-06-11       Impact factor: 2.430

7.  Inter-unit variability in two ParvoMedics TrueOne 2400 automated metabolic gas analysis systems.

Authors:  D J Macfarlane; H L Wu
Journal:  Eur J Appl Physiol       Date:  2012-09-04       Impact factor: 3.078

8.  Validity, reliability and minimum detectable change of COSMED K5 portable gas exchange system in breath-by-breath mode.

Authors:  Laura Guidetti; Marco Meucci; Francesco Bolletta; Gian Pietro Emerenziani; Maria Chiara Gallotta; Carlo Baldari
Journal:  PLoS One       Date:  2018-12-31       Impact factor: 3.240

9.  Inter- and intra-unit reliability of the COSMED K5: Implications for multicentric and longitudinal testing.

Authors:  Kay Winkert; Rupert Kamnig; Johannes Kirsten; Jürgen M Steinacker; Gunnar Treff
Journal:  PLoS One       Date:  2020-10-23       Impact factor: 3.240

10.  Comparison of Two Metabolic Simulators Used for Gas Exchange Verification in Cardiopulmonary Exercise Test Carts.

Authors:  Tjeu Souren; Edward Rose; Herman Groepenhoff
Journal:  Front Physiol       Date:  2021-06-03       Impact factor: 4.566

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.