Validity and stability of a computerized metabolic system with mixing chamber.

Ø Foss1, J Hallén.   

Abstract

The aim of this study was to validate a computerized metabolic system with mixing chamber (Oxycon Pro, Erich Jaeger GmbH, Hoechberg, Germany) against the Douglas bag method (1) over a large range of ventilations and (2) for drift during shorter (25-min time trial) and longer (approximately three months) test periods. Eighteen well-trained/elite cyclists performed graded exercise tests, maximal oxygen uptake tests and time trial tests on an electromagnetic braked cycle ergometer. Respiratory variables were measured simultaneously, once or several times in every test by the Oxycon Pro and the Douglas bag method. (1) Overall, oxygen uptake was 0.8 % (0.03 l x min(-1)) lower with the Oxycon Pro than with the Douglas bag method with a coefficient of variation of 1.2 % (n = 802) (p < 0.05). (2) During the time trials, oxygen uptake measured with the Oxycon Pro gradually decreased from 0.5 % (0.02 l) lower than the Douglas bag method at 5 min to 1.0 % (0.05 l) lower at 25 min (p < 0.05). Over the period of three months of testing, oxygen uptake measured with the Oxycon Pro gradually increased from 1.1 % (0.04 l) lower than the Douglas bag method at the start to 0.5 % (0.02 l) lower at the end (p < 0.05). This study demonstrates that a computerized metabolic system with mixing chamber is an accurate system for measuring oxygen uptake. This applies to testing over a large range of ventilations and for stability both during shorter and longer test periods.

Entities:  

Mesh:

Year:  2005        PMID: 16195991     DOI: 10.1055/s-2004-821317

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  34 in total

1.  Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

Authors:  D J Macfarlane; P Wong
Journal:  Eur J Appl Physiol       Date:  2011-11-11       Impact factor: 3.078

2.  Effect of heavy strength training on muscle thickness, strength, jump performance, and endurance performance in well-trained Nordic Combined athletes.

Authors:  Bent R Rønnestad; Oystein Kojedal; Thomas Losnegard; Bent Kvamme; Truls Raastad
Journal:  Eur J Appl Physiol       Date:  2011-10-29       Impact factor: 3.078

3.  Validation of the SenseWear Armband at high intensity exercise.

Authors:  Clemens Drenowatz; Joey C Eisenmann
Journal:  Eur J Appl Physiol       Date:  2010-10-24       Impact factor: 3.078

4.  Cadence and performance in elite cyclists.

Authors:  Øivind Foss; Jostein Hallén
Journal:  Eur J Appl Physiol       Date:  2004-10-21       Impact factor: 3.078

5.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

6.  Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique.

Authors:  Sepideh Kaviani; Dale A Schoeller; Eric Ravussin; Edward L Melanson; Sarah T Henes; Lara R Dugas; Ronald E Dechert; George Mitri; Paul F M Schoffelen; Pim Gubbels; Asa Tornberg; Stephen Garland; Marco Akkermans; Jamie A Cooper
Journal:  Nutr Clin Pract       Date:  2018-04       Impact factor: 3.080

7.  Effect of heavy strength training on thigh muscle cross-sectional area, performance determinants, and performance in well-trained cyclists.

Authors:  Bent R Rønnestad; Ernst Albin Hansen; Truls Raastad
Journal:  Eur J Appl Physiol       Date:  2009-12-04       Impact factor: 3.078

8.  The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Authors:  Hans Rosdahl; Thomas Lindberg; Fredrik Edin; Johnny Nilsson
Journal:  Eur J Appl Physiol       Date:  2012-12-07       Impact factor: 3.078

9.  HIT maintains performance during the transition period and improves next season performance in well-trained cyclists.

Authors:  Bent R Rønnestad; Arild Askestad; Joar Hansen
Journal:  Eur J Appl Physiol       Date:  2014-05-31       Impact factor: 3.078

Review 10.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.