Literature DB >> 10398964

A practical double-tuned 1H/31P quadrature birdcage headcoil optimized for 31P operation.

G B Matson1, P Vermathen, T C Hill.   

Abstract

A double-tuned 1H/31P birdcage head coil for use with humans at 1.5 T is described. The coil was designed for proton-decoupled 31P excitation and reception and incorporated a number of practical features including optimized sensitivity for 31P, quadrature operation at 1H and 31P frequencies, and a radiofrequency (RF) mirror for improved B1 homogeneity. The design achieved similar B1 homogeneity at both 31P and 1H frequencies. Inductive matching was used to accommodate samples with large loading differences. A facile method for tuning and matching over a variety of sample loadings is presented, along with capacitively shortened bazookas for suppression of cable braid currents. The proton sensitivity, although down by approximately a factor of two compared with an optimized 1H birdcage head coil, was still ample for shimming and generation of scout images. Advantages of the design are discussed and proton-decoupled 31P spectra of human brain are presented.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10398964     DOI: 10.1002/(sici)1522-2594(199907)42:1<173::aid-mrm23>3.0.co;2-o

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

2.  A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T.

Authors:  Yong Pang; Zhentian Xie; Duan Xu; Douglas A Kelley; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

3.  Trap Design and Construction for High-Power Multinuclear Magnetic Resonance Experiments.

Authors:  Joseph V Rispoli; Ivan E Dimitrov; Sergey Cheshkov; Craig Malloy; Steven M Wright; Mary P McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-11-17       Impact factor: 1.176

4.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

5.  Signal enhancement through heteronuclear polarisation transfer in in-vivo 31P MR spectroscopy of the human brain.

Authors:  W Weber-Fahr; P Bachert; F A Henn; D F Braus; G Ende
Journal:  MAGMA       Date:  2003-07-16       Impact factor: 2.310

Review 6.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

7.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12

8.  Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy.

Authors:  Wm Potter; L Wang; Kk McCully; Q Zhao
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2013-08-01       Impact factor: 1.176

9.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

10.  3D 31 P MR spectroscopic imaging of the human brain at 3 T with a 31 P receive array: An assessment of 1 H decoupling, T1 relaxation times, 1 H-31 P nuclear Overhauser effects and NAD.

Authors:  Tom H Peeters; Mark J van Uden; Anne Rijpma; Tom W J Scheenen; Arend Heerschap
Journal:  NMR Biomed       Date:  2019-09-13       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.