Literature DB >> 18299877

Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole.

Tetsu Shiratani1, Kimiya Shimizu, Kunitoshi Fujisawa, Shigekazu Uga, Koichi Nagano, Yuuki Murakami.   

Abstract

BACKGROUND: We calculated the smallest diameter of a hole in the center of the optic at which the optical character of a phakic IOL (ICL) may be maintained. The changes induced in the aqueous humor dynamics and the pathology of cataract development with such a hole were investigated.
METHODS: A simulation was performed using ZEMAX software to calculate the hole diameter that makes possible the maintenance of a stable optical character of a phakic IOL. After a hole of calculated diameter was trepanned in the center of the optic of the ICL, the latter was implanted into one eye of a 5-month-old minipig, and an unperforated ICL into the other. The postoperative course was observed for 3 months. Then, Evans blue was injected into the vitreous body under general anesthesia to stain the anterior capsule of the crystalline lens. Within 30 min, the eye was enucleated and the tissues removed were fixed.
RESULTS: The MTF of the perforated ICL (hole diameter, 1.0 mm) in the center of the optic resembled that of the unperforated ICL. In all cases with non-perforated ICLs, subcapsular turbidity developed, but no staining caused by EB was observed in the anterior capsule. On the other hand, the anterior capsules of the eyes fitted with ICLs with a 1.0-mm hole were stained, but exhibited no turbidity.
CONCLUSION: An ICL with a central hole of diameter 1.0 mm in the optic is similar to an unperforated ICL. The size of the hole influenced the aqueous humor dynamics and increased the aqueous humor perfusion volume over the entire anterior surface of the crystalline lens. The possibility of preventing cataracts was therefore suggested.

Entities:  

Mesh:

Year:  2008        PMID: 18299877      PMCID: PMC2292472          DOI: 10.1007/s00417-007-0759-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  17 in total

1.  Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.

Authors:  Kunitoshi Fujisawa; Kimiya Shimizu; Shigekazu Uga; Masanobu Suzuki; Koichi Nagano; Yuuki Murakami; Hiroko Goseki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-25       Impact factor: 3.117

2.  Consultation section: cataract surgical problem.

Authors: 
Journal:  J Cataract Refract Surg       Date:  2003-06       Impact factor: 3.351

3.  Phakic posterior chamber lenses for high myopia: functional and anatomical outcomes.

Authors:  J L Arne; L C Lesueur
Journal:  J Cataract Refract Surg       Date:  2000-03       Impact factor: 3.351

4.  Implantable contact lens for high myopia.

Authors:  Risto J Uusitalo; Esko Aine; Nida H Sen; Leila Laatikainen
Journal:  J Cataract Refract Surg       Date:  2002-01       Impact factor: 3.351

5.  Repair and reconstruction of the mouse lens after perforating injury.

Authors:  Sawori Hirayama; Akino Wakasugi; Tetsuya Morita; Yasuhiro Sakai; Kazuo Mukuno; Shigekazu Uga; Kimiya Shimizu
Journal:  Jpn J Ophthalmol       Date:  2003 Jul-Aug       Impact factor: 2.447

6.  U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia.

Authors:  Donald R Sanders; John A Vukich; Kimberley Doney; Monica Gaston
Journal:  Ophthalmology       Date:  2003-02       Impact factor: 12.079

7.  Response of the mouse lens to varying sizes of injured area.

Authors:  Akino Wakasugi; Shigekazu Uga; Yasuhiro Sakai; Miho Matsumoto; Saori Hirayama; Kimiya Shimizu
Journal:  Jpn J Ophthalmol       Date:  2002 Jul-Aug       Impact factor: 2.447

8.  Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation.

Authors:  Michel Gonvers; Chantal Bornet; Philippe Othenin-Girard
Journal:  J Cataract Refract Surg       Date:  2003-05       Impact factor: 3.351

9.  Movement of cysteine in intact monkey lenses: the major site of entry is the germinative region.

Authors:  Matthew H J Sweeney; Donita L Garland; Roger J W Truscott
Journal:  Exp Eye Res       Date:  2003-08       Impact factor: 3.467

10.  Morphological analysis of iodoacetic acid-induced cataract in the rat.

Authors:  Miho Matsumoto; Tetsuya Morita; Saori Hirayama; Shigekazu Uga; Kimiya Shimizu
Journal:  Ophthalmic Res       Date:  2002 May-Jun       Impact factor: 2.892

View more
  22 in total

1.  Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

Authors:  Takushi Kawamorita; Hiroshi Uozato; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-11-01       Impact factor: 3.117

Review 2.  The parameters of the porcine eyeball.

Authors:  Irene Sanchez; Raul Martin; Fernando Ussa; Ivan Fernandez-Bueno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-02-02       Impact factor: 3.117

3.  Modulation transfer function of intraocular collamer lens with a central artificial hole.

Authors:  Hiroshi Uozato; Kimiya Shimizu; Takushi Kawamorita; Fumiko Ohmoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-01-13       Impact factor: 3.117

4.  A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport.

Authors:  Kyu-Yeon Hwang; Sung A Lim; So-Hyang Chung
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

5.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

6.  Influence of across-pupil sutures on the optical quality of intraocular lenses.

Authors:  Chang Rae Rho; Min-Ji Kim; Choun-Ki Joo
Journal:  Int Ophthalmol       Date:  2017-02-04       Impact factor: 2.031

7.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

8.  Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

Authors:  Takushi Kawamorita; Kimiya Shimizu; Nobuyuki Shoji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-19       Impact factor: 3.117

9.  Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Aya Saito; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

10.  Artiflex versus STAAR implantable contact lenses for correction of high myopia.

Authors:  Mohammad Ghoreishi; Amin Masjedi; Kobra Nasrollahi; Aminhossein Rahgozar; Keivan Jenab; Hamid Fesharaki
Journal:  Oman J Ophthalmol       Date:  2011-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.