Literature DB >> 22027367

Time-resolved interventional cardiac C-arm cone-beam CT: an application of the PICCS algorithm.

Guang-Hong Chen1, Pascal Theriault-Lauzier, Jie Tang, Brian Nett, Shuai Leng, Joseph Zambelli, Zhihua Qi, Nicholas Bevins, Amish Raval, Scott Reeder, Howard Rowley.   

Abstract

Time-resolved cardiac imaging is particularly interesting in the interventional setting since it would provide both image guidance for accurate procedural planning and cardiac functional evaluations directly in the operating room. Imaging the heart in vivo using a slowly rotating C-arm system is extremely challenging due to the limitations of the data acquisition system and the high temporal resolution required to avoid motion artifacts. In this paper, a data acquisition scheme and an image reconstruction method are proposed to achieve time-resolved cardiac cone-beam computed tomography imaging with isotropic spatial resolution and high temporal resolution using a slowly rotating C-arm system. The data are acquired within 14 s using a single gantry rotation with a short scan angular range. The enabling image reconstruction method is the prior image constrained compressed sensing (PICCS) algorithm. The prior image is reconstructed from data acquired over all cardiac phases. Each cardiac phase is then reconstructed from the retrospectively gated cardiac data using the PICCS algorithm. To validate the method, several studies were performed. Both numerical simulations using a hybrid motion phantom with static background anatomy as well as physical phantom studies have been used to demonstrate that the proposed method enables accurate reconstruction of image objects with a high isotropic spatial resolution. A canine animal model scanned in vivo was used to further validate the method.

Entities:  

Mesh:

Year:  2011        PMID: 22027367      PMCID: PMC3367866          DOI: 10.1109/TMI.2011.2172951

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  38 in total

1.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.

Authors:  Jie Tang; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Towards cardiac C-arm computed tomography.

Authors:  Günter Lauritsch; Jan Boese; Lars Wigström; Herbert Kemeth; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

4.  Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite--a comparison between multisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography.

Authors:  Amin Al-Ahmad; Lars Wigström; Dominique Sandner-Porkristl; Paul J Wang; Paul C Zei; Jan Boese; Günter Lauritsch; Teri Moore; Frandics Chan; Rebecca Fahrig
Journal:  Heart Rhythm       Date:  2008-01-11       Impact factor: 6.343

5.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

7.  Three-dimensional rotational angiography of the left atrium and esophagus--A virtual computed tomography scan in the electrophysiology lab?

Authors:  Michael V Orlov; Peter Hoffmeister; G Muqtada Chaudhry; Ibrahim Almasry; Geert H M Gijsbers; Tammee Swack; Charles I Haffajee
Journal:  Heart Rhythm       Date:  2006-10-13       Impact factor: 6.343

8.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

9.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

10.  Intraprocedural volume imaging of the left atrium and pulmonary veins with rotational X-ray angiography: implications for catheter ablation of atrial fibrillation.

Authors:  Aravinda Thiagalingam; Robert Manzke; Andre D'Avila; Ivan Ho; Andrew H Locke; Jeremy N Ruskin; Raymond C Chan; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2007-11-12
View more
  25 in total

1.  SPULTRA: Low-Dose CT Image Reconstruction With Joint Statistical and Learned Image Models.

Authors:  Siqi Ye; Saiprasad Ravishankar; Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

2.  PWLS-ULTRA: An Efficient Clustering and Learning-Based Approach for Low-Dose 3D CT Image Reconstruction.

Authors:  Xuehang Zheng; Saiprasad Ravishankar; Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

3.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

4.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

5.  Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data.

Authors:  Kerstin Müller; Chris Schwemmer; Joachim Hornegger; Yefeng Zheng; Yang Wang; Günter Lauritsch; Christopher Rohkohl; Andreas K Maier; Carl Schultz; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

Authors:  K Müller; A K Maier; C Schwemmer; G Lauritsch; S De Buck; J-Y Wielandts; J Hornegger; R Fahrig
Journal:  Phys Med Biol       Date:  2014-05-20       Impact factor: 3.609

7.  Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Gerhard Kleinszig; Sebastian Vogt; Gary L Gallia; A Jay Khanna; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

8.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

9.  Sinogram smoothing techniques for myocardial blood flow estimation from dose-reduced dynamic computed tomography.

Authors:  Dimple Modgil; Adam M Alessio; Michael D Bindschadler; Patrick J La Rivière
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

10.  Iterative reconstruction for x-ray computed tomography using prior-image induced nonlocal regularization.

Authors:  Hua Zhang; Jing Huang; Jianhua Ma; Zhaoying Bian; Qianjin Feng; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  IEEE Trans Biomed Eng       Date:  2013-10-24       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.